Power LEDs
(item 10 from other side)
AC Power Wiring Diagram
(Refer to Encompass Reader System Guide for DC Power Wiring Diagram.)
Choosing a Power Supply
Consider these factors when choosing a power supply:
1. Input voltage: 19V to 30V DC or 19V to 27V AC RMS
@47 to 63 Hz, in-rush current: 8A maximum,
25 ms. (See Power
Requirements on other side for additional Encompass 5
requirements.)
2. Operating temperature of power supply and power cable
3. Power cable gauge and length. TransCore recommends using
12 to 22 AWG cable to Encompass 5.
Power Supply Accessory Kit
Part Number
Description
76-6000-001
110V AC or 220V AC to 24V AC transformer
CAUTION:
Wire gauge depends on wire resistance versus overall wire length with
respect to the Encompass 5 reader’s specified voltage range and power rating.
POWER LED
INDICATION
PWR
19V to 30V DC or 19V to 27V AC supplied
+5
+5 volt power supply functioning
+10.5
+10.5 volt power supply functioning
+5.5
+5.5 volt power supply functioning
+7
+7 volt power supply functioning
-5.5
-5.5 volt power supply functioning
Fault/Operational LEDs
(item 11 from other side)
THREE FAULT INDICATION LEDs
*
ERR3
ERR2
ERR1
FAILURE MODE
Microprocessor resetting
Power supply failure
Transceiver failure
TDM/GPS failure
No communication with lane controller/host
Other failure
Data in buffer
No
failure
OPERATIONAL LEDs
INDICATION
RDR
Encompass 5 communicating with host
LC
Host communicating with Encompass 5
TIF
Encompass 5 transacting with tag. LED lit
when Encompass 5 receives correctly
decoded tag message including correct cyclic
redundancy check for message. The LED is lit
for 250 ms following a tag transaction.
UL
RF uplink signal on
DL
RF downlink signal on
*
If multiple faults occur, the highest priority fault displays. For example, if the
microprocessor is resetting (highest priority) and the power supply fails
(second highest priority), the microprocessor fault indication displays until it is
cleared.
Equipment Licensing
The user is required to obtain a Part 90 site license from
the FCC to operate the unit in the United States. Access
the FCC Web site at www.fcc.gov for more information.
FCC ID: FIHMPI6000
Users in all countries should check with the appropriate
local authorities for licensing requirements.
Troubleshooting
Perform these troubleshooting procedures:
1. Make sure all connectors are secure.
2. Make sure Encompass 5 is powered up by checking
Power LEDs.
3. Make sure Encompass 5 is communicating with host.
If system does not respond to troubleshooting, contact TransCore
Customer Service at transcore.com/rfidsupport.
Start Up
Perform the following startup procedures:
1. Connect antenna to Encompass 5 at RF MONO port.
2. Connect COM1 or Ethernet cable depending on
communication configuration.
3. Connect other options as needed.
4. Connect AC or DC power to Encompass 5.
Power LEDs should light.
5. Set commands as required for your application.
6.
Send Set Mode command to Encompass 5 from host.
A