Power LEDs

(item 10 from other side)

AC Power Wiring Diagram

(Refer to Encompass Reader System Guide for DC Power Wiring Diagram.)

Choosing a Power Supply

Consider these factors when choosing a power supply:

1.  Input voltage: 19V to 30V DC or 19V to 27V AC RMS 

@47 to 63  Hz,  in-rush current: 8A  maximum, 

25 ms. (See Power 

Requirements  on other side for  additional  Encompass  5 
requirements.) 

2.  Operating temperature of power supply and power cable 
3.  Power cable gauge and length. TransCore recommends using 

12 to 22 AWG cable to Encompass 5. 

 

Power Supply Accessory Kit 

Part Number 

Description 

76-6000-001 

110V AC or 220V AC to 24V AC transformer 

 

CAUTION:

 Wire gauge depends on wire resistance versus overall wire length with 

respect to the Encompass 5 reader’s specified voltage range and power rating.

POWER LED 

INDICATION 

 

PWR 

19V to 30V DC or 19V to 27V AC supplied 

 

+5 

+5 volt power supply functioning 

 

+10.5 

+10.5 volt power supply functioning 

 

+5.5 

+5.5 volt power supply functioning 

 

+7 

+7 volt power supply functioning 

 

-5.5 

-5.5 volt power supply functioning 

 

Fault/Operational LEDs

(item 11 from other side)

 

THREE FAULT INDICATION LEDs

*

 

 

ERR3

ERR2

ERR1

FAILURE MODE 

Microprocessor resetting  

Power supply failure 

Transceiver failure  

TDM/GPS failure 

No communication with lane controller/host 

Other failure

Data in buffer 

 

 

 No 

failure 

OPERATIONAL LEDs

INDICATION 

RDR

Encompass 5 communicating with host

LC

Host communicating with Encompass 5

TIF 

Encompass 5 transacting with tag. LED lit 
when Encompass 5 receives correctly 
decoded tag message including correct cyclic 
redundancy check for message. The LED is lit 
for 250 ms following a tag transaction. 

UL

RF uplink signal on

DL

RF downlink signal on 

*

If multiple faults occur, the highest priority fault displays. For example, if the 

microprocessor is resetting (highest priority) and the power supply fails 
(second highest priority), the microprocessor fault indication displays until it is 
cleared.

Equipment Licensing

The user is required to obtain a Part 90 site license from 
the FCC to operate the unit in the United States. Access 
the FCC Web site at www.fcc.gov for more information. 
 
FCC ID: FIHMPI6000 
 
Users in all countries should check with the appropriate 
local authorities for licensing requirements.

 

Troubleshooting

Perform these troubleshooting procedures:

1.  Make sure all connectors are secure. 
2.  Make sure Encompass 5 is powered up by checking 

Power LEDs. 

3.  Make sure Encompass 5 is communicating with host. 
 
If system does not respond to troubleshooting, contact TransCore 
Customer Service at transcore.com/rfidsupport. 

Start Up

Perform the following startup procedures: 

1.  Connect antenna to Encompass 5 at RF MONO port. 
2.  Connect COM1 or Ethernet cable depending on 

communication configuration. 

3.  Connect other options as needed. 
4.  Connect AC or DC power to Encompass 5. 

Power LEDs should light. 

5.  Set commands as required for your application. 

6. 

Send Set Mode command to Encompass 5 from host.

 