Encompass 4 Reader System Guide
TransCore Proprietary.
7–98
456 Enable eGo Plus Tag Initialization During Multi-tag Sort (Factory Default)
Command
#456
enables the reader to send the eGo Plus Tag initialize command as part of the multi-tag
sort function. When the reader sends the eGo Plus Tag initialize command, all tags in the RF field reenter
the sort process.
Reader response:
Done
457 Disable eGo Plus Tag Initialization During Multi-tag Sort
Command
#457
disables the reader from sending the eGo Plus Tag initialize command as part of the
multi-tag sort function. Any eGo Plus Tags already identified by the reader during the sort process will not
be re-identified as long as they remain powered in the RF field. The reader will only identify new tags that
come into the RF field or tags that do not remain powered in the RF field.
Reader response:
Done
458 Disable Second Alternate Group Select (Factory Default)
Command
#458
is a default set in the factory to disable the second alternate group select function.
Reader response:
Done
459 Enable Second Alternate Group Select
Command
#459
enables the second alternate group select function that allows the reader to distinguish
tags meeting specific criteria pre-programmed into the tags.
“Macau” 10 = 00, 12 through 17 = 01, 51, 58, 71, 11, 06
Caution
When second alternate group select is enabled, tags not programmed to meet the specified
criteria will not be read.
Reader response:
Done
46NN Set Wiegand Retransmit Interval
See
“533 Display Wiegand Retransmit Interval” on page 7–110.
Command
#46NN
sets the time delay to control the reader retransmission of Wiegand data of a tag
remaining in the read zone where
NN
is a hexadecimal code from 01 to FF.
This command works for non-Wiegand tags with Wiegand Translation Mode enabled.
Note:
The actual value of the Wiegand retransmit interval may vary depending on the operative tag
read mode and the type of tag in the read field.