Installing the IT2200 Reader System
4-19
To install the RF module
1.
Locate the RF module atop the mounting pipe and insert a U-bolt around the pole
and up through the bracket. Place a spacer over each section of the U-bolt
protruding through the bracket and place a lock washer and nut over each side of
the U-bolt. Repeat for the other U-bolt.
Note: Depending on pole diameter, spacers may or may not be needed.
2.
Tighten nuts with torque wrench to 68 N-m (50 ft-lb). Tighten second nut over
first nut to lock it in place.
3.
Check that 19 to 28 VAC or 16 to 28 VDC power is available at the module end
of the power cable. Measure the voltage across pins A and C of the power cable
connector.
4.
Connect the power cable to the RF module’s power supply plug (Figure 4-14).
5.
Connect the data cable to the RF module’s data connector.
Figure 4-14 IT2611 RF Module Connectors (Monostatic RF Module Shown)
Installing the AA3152 UTA
The UTA is mounted on a 5.0 to 7.6cm (2- to 3-in) pipe to accommodate various
angles for lane tuning. Two UTAs are required for each dedicated or mixed-use lane
in a bistatic configuration. One UTA is required for each dedicated or mixed-use lane
Содержание Amtech IT2200
Страница 1: ...IT2200ReaderSystem P N 411554 Installation Maintenance Service Guide withMultimodeCapability...
Страница 2: ......
Страница 5: ......
Страница 6: ......
Страница 7: ...Contents...
Страница 8: ......
Страница 19: ...1 Before You Begin...
Страница 20: ......
Страница 25: ...2 Theory of Operation...
Страница 26: ......
Страница 41: ...3 System Components...
Страница 42: ......
Страница 67: ...4 Installing the IT2200 Reader System...
Страница 68: ......
Страница 91: ...5 Tuning the Lane...
Страница 92: ......
Страница 109: ...6 Troubleshooting the Installation...
Страница 110: ......
Страница 129: ...7 Preventive Maintenance...
Страница 130: ......
Страница 133: ...A Acronyms and Glossary...
Страница 134: ......
Страница 142: ...IT2200 Reader System with Multimode Capability Installation Maintenance Service Guide A 10...
Страница 143: ...B Block Diagrams...
Страница 144: ......
Страница 147: ...Block Diagrams B 5 IT2020 Reader Logic Card Figure B 3 IT2020 Reader Logic Card Functional Block Diagram...
Страница 149: ...Block Diagrams B 7 Figure B 5 Minimum Connections for the IT2020 Reader Logic Card Interface Bistatic Application...
Страница 151: ...Block Diagrams B 9 IT2611 RF Module Figure B 7 IT2611 RF Module Functional Block Diagram Bistatic Configuration...
Страница 153: ...C System Technical Specifications...
Страница 154: ......
Страница 160: ...IT2200 Reader System with Multimode Capability Installation Maintenance Service Guide C 8...
Страница 161: ...D Hardware Interfaces...
Страница 162: ......
Страница 185: ...E Connector Pin outs...
Страница 186: ......
Страница 204: ...IT2200 Reader System with Multimode Capability Installation Maintenance Service Guide E 20...