background image

T

CT

Start up Guide

Series Balances

Transcat.com | 800.828.1470

Содержание Procision TCT Series

Страница 1: ...TCT Start up Guide Series Balances Transcat com 800 828 1470...

Страница 2: ...unding foot x 1 Foot x 3 Models TCT 363 C TCT 603 C TCT 1003 C TCT 3003 C Weighing pan x 1 Balance x 1 Foot x 3 Grounding foot x 1 Models TCT 2102 C Models TCT 4502 C TCT 6002 C TCT 8102 C TCT 10102 C...

Страница 3: ...e balance in a hazardous area Do not weigh explosive materials Do not place the balance on an unstable ground exposed to shocks and vibrations 40 o C 104o F 10 o C 50o F Operate the device in a room w...

Страница 4: ...should a warranty claim or service be required Check the grounding spring Make sure that the grounding spring juts slightly out of the hole Check the grounding spring Make sure that the grounding spri...

Страница 5: ...ed opening Install the grounding foot in a freely selected opening Models TCT 2102 C Models TCT 164 C TCT 224 C TCT 314 C TCT 524 C Models TCT 363 C TCT 603 C TCT 1003 C TCT 3003 C Models TCT 4502 C T...

Страница 6: ...sary to ensure that it has reached a temperature equal to room temperature Connect the power adapter to DC connector Connect the power adapter to the mains Balance temperature stabilization time range...

Страница 7: ...he semi micro and analytical balances feature a digital leveling system 6 3 Leveling Press leveling icon Check the balance level state The arrows show how to turn the feet to level the balance Keep tu...

Страница 8: ...report Zeroing Displaying previous screen Proximity sensor Homescreen Only available on semi micro and analytical models Taring Working modes list List of current working mode functions Status bar We...

Страница 9: ...djustment button Wait for the process completion 8 2 Zeroing 8 3 Taring 2 1 Unload the weighing pan and press Zeroing button The balance has been zeroed The balance has been tared 2 1 When the weighin...

Страница 10: ...ghing Dosing Checkweighing Formulas Percent weighing Statistics Parts counting Animal weighing Solids density Liquids density Peak hold Users list is displayed select Admin option Units list g mg ct l...

Страница 11: ...5 7 2 1 Press Databases button Select Operator database Enter user name Following the above procedure set remaining parameters Code Enter user ID Password Enter user password Access levels Set respect...

Страница 12: ...this time select Left Sensor parameter Following the above procedure you can also set sensors for remaining working modes 9 3 Proximity sensors setup 1 2 3 4 5 6 Press Parameters button Select Weighin...

Страница 13: ...10 PERIPHERAL DEVICES CONNECTORS...

Страница 14: ...ended for scrubbing Make sure that dust nor liquid gets inside the weighing system 11 2 Cleaning Instructions GLASS PANES AND COMPONENTS can be cleaned using window cleaner WEIGHING PANS AND STAINLESS...

Страница 15: ...g chamber make sure the balance is turned off and unplugged form the mains Press the moldings on the housing and lift the movable element up Now you can remove the front glass Press the moldings on th...

Страница 16: ...the back glass The housing has recesses to facilitate removing the glass Slide out the doors All disassembled elements are prepared to be cleaned To reassemble draft shield follow directions in revers...