Setup of serial ports parameters
Chapter 6. Commissioning.Internal configuration
57
Chan. Load (last)
– Previous frame channel load (note2);
Bad CRCR cntr
– Number of (messages with bad CRC) (note2);
Chan. Load (forecast)
– Forecast channel load (note2);
Noise level
– Average noise level (note2);
RSSI (frame)
– Received signal strength (note2);
VDM/VSI out
– Provide VSI sentence with each VDM sentence (note3);
VDO/VSI out
– Provide VSI sentence with each VDO sentence (note3);
FSR out
– Provide FSR sentence after each frame (note3).
Notes:
1.
0 = no output
1 = continuous output
2 = output next frame only
2.
0 = no output
1 = output once per frame
2 = output next frame only
3.
0 = off, disabled
1 = on, enabled
6.5
SETUP OF SERIAL PORTS PARAMETERS
When external devices are connected to the serial ports, it is necessary to make
settings of the port status, baud rate, parity and the stop bit number. This is done in
the Configuration->Setup->Serial port setup menu.
Standard port settings:
Port name
St.
Parameters
Notes
Sensor 1
Off
-
Please don’t change
Sensor 2 (external
Sensor port)
On
4800, N, One
Sensor 3
Off
-
Please don’t change
Int.GNS
On
4800, N, One
Please don’t change
Main (internal)
On
38400, N, One
Internal port. Please don’t
change, refer to 5.1
Aux (internal)
On
38400, N, One
Internal port. Please don’t
change, refer to 5.1
Содержание T214
Страница 1: ... Transas Ltd April 2007 TRANSAS AIS BASE STATION T214 TECHNICAL MANUAL ...
Страница 6: ......
Страница 8: ......
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 30: ......
Страница 40: ......
Страница 42: ......
Страница 48: ......
Страница 52: ...Service Display program TRANSAS AIS BASE STATION T214 Technical Manual 50 ...
Страница 84: ......
Страница 100: ......
Страница 102: ......
Страница 108: ......
Страница 110: ......