Thermostat

Model TZEMT400AB32MAA

Installation Instructions

Tools Needed

1/8”

#2

 

Note about dual fuel systems: This thermostat is not

compatible with dual fuel systems (heating system with both heat 
pump and gas furnace), unless the system is controlled with a dual 
fuel accessory relay kit.  If you are unsure whether your dual fuel 
system is controlled with this accessory or if you need a dual fuel kit, 
please contact a qualifi ed heating and cooling contractor.

1

WARNING

Voltage hazard. Can cause electrical shock or equipment damage. Disconnect power to 
heating and cooling equipment before beginning installation.

2

Remove the existing thermostat cover from the wall plate.

Leave wires attached.
Consult instructions that came with existing thermostat as needed.

Wall plate

Thermostat cover

The look of your existing 

thermostat may vary

Physical Installation and Wiring

1

The thermostat 

is compatible with single

and multistage forced air systems, including:

 

• Gas furnace systems

 

• Oil furnace systems

 

• Electric furnace systems

 

• Heat pump systems

 

• Air conditioning systems

The thermostat 

may be compatible with 

some other system types, including:

 

• Boiler systems

 

• Geothermal systems

 

• Multi-zoned systems

The thermostat 

is not compatible with the 

following system types:

 

• Radiant fl

 oor systems

 

 Wall heating systems

Also, the thermostat 

is not compatible with 

dual fuel systems (gas furnace & heat pump combined) 

without adding a special kit. See Note below.

P516-393

3A

2

If you are unsure about connecting this wire or you do not have any unused wires at the 

thermostat, contact Customer Service.

Connect a 24 VAC common wire to power the thermostat.

3

Determine if your system has a 24 VAC common wire which is required to power the thermostat.
If your system is a heat pump, skip to step 4.

a.  If your existing thermostat has a terminal named C, COM, X, or B with a wire connected to it, skip to step 4.
b.  If your thermostat does not have that terminal, or does not have a wire connected to it, go to step 3a.

a.  Locate all unused (disconnected) wires from the
     thermostat wire bundle and write down the colors.

 

24V Common wire is typically (not always) colored blue

Unused wires

Thermostat
wire bundle

c. Find the 24 VAC common terminal identified with
    the letter C, X, B, or COM. 

This terminal may already have a wire connected to it  

 

    but it may not be a wire that goes to the thermostat

f. Connect the unused wire to the 24 VAC terminal, 
   then replace the furnace cover. 

The 24 VAC common wire is typically (but not always)  

 

    blue in color. If the blue wire has been unused, it is  

 

    recommended that you use the blue wire.

e. Find a wire from the thermostat bundle that is 
    unused at the thermostat and at the furnace. 

It is possible that one of the unused wires at the   

 

   thermostat will already be connected to the 24 VAC  

 

   common terminal at the furnace. If so, go to step 4.

b. Go to your HVAC unit and remove the cover(s) to   
    access the 24 VAC furnace wire terminals.

24 VAC

Furnace

wire

terminals

Furnace

cover

24 VAC common

terminal

(C, X, B, or COM)

G

W

R

C

G

Thermostat

wire bundle

G

W

R

C

Unused

 wires

G

G

W

R

C

Unused

 wire

G

G

W

R

C

Connect

 wire

G

d. Locate the thermostat wire bundle inside the
    furnace panel.

 

This wire bundle is routed from the thermostat,  

 

    through the walls, and into the furnace panel.

 

This bundle can be identified at the furnace by  

 

    checking the wire colors connected and not  

 

    connected and comparing to the wire bundle at the  

 

    thermostat.

Label the wires on your existing thermostat to match terminal names.

Do not use wire colors to chose labels. The terminal name 
is what is important.

a.  Locate the wiring labels located in the box with the new thermostat. 
b.  Look at where each wire is connected to the existing thermostat and fi nd the 

letter shown next to that wire terminal.

c.  Peel off the matching label and wrap it around each corresponding wire.

Important Notes:
If you have a short jumper wire between two terminals, remove the jumper and do 
not label it. This jumper wire is not required on the new thermostat.

If you had to connect a new 24 VAC common wire in step 3a, you will use the “C” 
label on that wire.

If you have a W terminal, use the W1 label on that wire.

If your thermostat has any terminals with names that do not match any on the label,  
write down the terminal names and wire colors for later reference.

Y

Y

G

W1

C

R

G

Rc R

C

Wire colors and 
letters may vary

!

W1

3

4

B

C

E

F

G

O

L Y1 Y2

Rc

R

Rh

R

X2 T W1 W2 W3 X

Y

P516-001 R

ev

. 03/09-a

2 Y

1 Y

L

O

G

F

E

C

B

Rc

R

Rh

R

Y

X

3 W

2 W

1 W

T

2 X

5

Remove existing wall plate.
Note: During this process, make sure that the wires do 
not pull back into wall opening.

a.  Detach all wires from wall plate.
b.  Remove all screws attaching the wall plate to the 

wall and remove wall plate.

c.  See “MERCURY NOTICE” below.

MERCURY N

O

TICE

When this control is replacing an old control that contains mercury in 

a sealed tube, do not dispose of your old control in the trash.  Dispose 

of properly.  Contact your local waste management authority for 

instructions regarding recycling and proper disposal of the old control.

A listing of heating, ventilating and air conditioning wholesalers that 

participate in the Thermostat Recycling Corporation’s recycling 

program are available at www.thermostat-recyle.org .

Wall plate

6

Identify your System Type  from the list below.
You will need to check your wire labels to help identify the system type.

CA

UTION

: EQUIPMENT DAMA

GE HAZARD - 

Improper system type selection can lead to equipment damage 

or high utility costs.  Follow the System Type table carefully to properly select and setup the control to ensure proper 
heating and cooling system operation.

Gas Furnace

Single Stage

Gas Furnace

Multi Stage

W2 label = multi stage heating

Y2 label = multi stage cooling

Electric

Furnace

Heat

Pump

Electric

Furnace 

Single Stage

Electric

Furnace

Multi Stage

W2 label = multi stage heating

Y2 label = multi stage cooling

Heat Pump

Single Stage

Heat Pump

Multi Stag

e

Does NOT have

W2 or Y2 wire label

Has a

W2 or Y2 wire label

Does NOT have an

O or B wire label

Has an O or B

wire label

Does NOT have

Y2 wire label

Has a

Y2 wire label

STAR

T HERE IF

You have a 

GAS furnace

STAR

T HERE IF

You have an 

ELECTRIC furnace or air handler

Does NOT have

W2 or Y2 wire label

Has a

W2 or Y2 wire label

OR

4

10

Install new wall plate.

a.  Pull wires through hole in center of wall plate.
b.  Locate the new wall plate over existing opening.
c.  Attach wall plate to wall using two screws provided. Do not overtighten.

24COM

24R

C

24RH
W1
W2/0

G
Y1
Y2

7

Separate the face of the new thermostat from the wall plate.
Apply pressure at two tabs on top of wall plate to release it.

Wall plate

24C

OM

24R

C

24R

H

W1
W2

/0
G
Y1
Y2

Tabs

8

Mark two mounting holes using new wall plate.

a.  Pull wires through hole in center of wall plate.
b.  Locate the new wall plate over existing opening.
c.  Mark two holes with pencil.
d.  Use a level to verify that the two holes locations are level. 
e.  Correct holes locations as needed.

24CO

M

24RC
24RH

W1
W2/0

G
Y1
Y2

9

Prepare two mounting holes.

a.  Drill 1/16” pilot holes in the two locations that were marked in step 9. 

If mounting to drywall with no studs behind it, enlarge pilot holes to 
1/8” for anchors.

b.  If using anchors, screw them into the holes.

Anchors

N

O

TE: It is not recommended that this Z-wave

TM

 

thermostat be mounted onto metal structures.  Metal 
may affect the radio frequency (RF) communication 
between the thermostat and the Z-wave

TM

 bridge.

5

6

11

Review the wiring chart information.

a.  Refer to:

 

Chart 1 - If you do NOT have a heat pump

 

Chart 2 - If you have a heat pump

b.  Select the correct row based upon the thermostat being replaced, and then circle the wire labels you have.
c.  Connect your wires as shown in the New Thermostat Terminals row.

Themostat Being Replaced

Wire Labels

All Brands

C
X
B

R

RC

RH

W

W1

W2

G
F

Y

Y1

Y2

Connects to

New Thermostat Terminals

24CO

M

24RC

24R

H

W1

W2/O/

B

G

Y1

Y2

 

Chart 1: Gas or Electric

(Single Stage or Multistage)

Themostat Being Replaced

Wire Labels

Trane/American Standard (Weathertron)
or York

COM

C
B

R

RC

RH

E

X2

W

W1
W2

Y

AUX

O

G

Y

Y1

Y2

Other Brands

COM

C
X

R

RC

RH

E

X2

W

W1
W2

Y

AUX

O
B

G
F

Y

Y1

Y2

Lennox

C
X

R

RC

**VR

**V

RH

E

X2

W

W1
W2

Y

AUX

O

**R

G
F

Y

Y1

Y2

Connects to

New Thermostat Terminals

24CO

M

24RC

24R

H

*W1

W2/

O/

B

G

Y1

Y2

  * Connect two wires to the W1 terminal

**If your existing thermostat has a “V” or “VR” wire label, connect that wire to “24RC” on the new thermostat, 

   then connect the wire labeled “R” to “W2/O/B” on the new thermostat

Chart 2: Heat Pump

(Single Stage or Multistage)

12

Attach all wires securely to the new thermostat.
Note: A wire must be connected to “24COM” to power the thermostat. 

a.  Use the information from step 11 to match the wires to the correct terminals.
b.  Use 1/8” blade screwdriver to secure wires in terminals.

24COM

24RC
24RH

W1

W2

CA

UTION

: EQUIPMENT DAMA

GE HAZARD 

- Improper 

wiring can lead to equipment damage. Follow the Terminal 
Connection information from step 11 carefully to ensure the 
control is wired properly. After wires are secure, bare wires
MUST NOT touch each other.

Some wire terminals may not be used

Some wire terminals may not be used

13

If necessary, cut the internal jumper wire (JP1).

Cutting the JP1 jumper
The jumper is located on back of the thermostat face as shown in the 
illustration to the right. Cut the jumper using small diagonal cutters being 
careful not to damage the board.

24COM

24RC

24RH

W1 
W2/0


Y1 
Y2

JP1

JP1

2

2

2

O

R

E

P

M

UJ 

T

U

C

H

R/

C

TI

L

P

S

JP1

2

2

2

O

R

E

P

M

UJ 

T

U

C

H

R/

C

TI

L

P

S

15

Turn power to heating and cooling system back on.
The thermostat display should turn on and begin displaying information. If the thermostat display does not come on, go back 
through the installation steps and look for problems. Pay special attention to steps 3, 3a, and 11.

14

Attach the thermostat face to the wall plate.

a.  Tuck wiring fl at inside the wall plate.

It is critical that wires are not bunched together and that the

y are pressed fl

 at.

b.  Carefully align the face plate to the wall plate while aligning pins into wire 

terminals.

c.  Once thermostat face is properly aligned, apply pressure at top and bottom 

of thermostat face until it is secure.

24COM

24RC
24RH

W1
W2/0

G
Y1
Y2

Wires
pressed flat

7

24RC

24RH

RC

24RC

24RH

W1

RH

OR

24RC

24RH

W1

RC

RH

Do N

O

T cut JP1 jumper

Cut JP1 jumper

If only one wire is connected

to either 24RC or 24RH

 as shown

If wires are connected to

both 24RC and 24RH

 as shown

8

17

If your System Type is:

Gas Furnace - Single St

age, go to step 

19

Gas Furnace - Multist

age, perform step 18A

Electric Furnace, perform step 18B

Heat Pump

, perform step 

18C

16

Set Time and Date

a.  Press the 

MENU button twice.

b.  Scroll up or down to 

User Settings (it is the fi rst 

option), then press the 

Select button.

MENU button

MENU   MODE     FAN       RUN

75

76 H
74 C

11:15 AM

c.  Scroll up or down to 

Set Clock (it is the fi rst option), 

then press the 

Select button.

d.  Press

or

to highlight the data you want to change.

e.  Scroll up or down (

or

 -

) to make changes. 

f. 

Press the 

Set button when you are fi nished.

g.  Press the 

Done button twice to exit the menu.

Done

Select

Menu Selection

User Settings
Usage Graph
ESM Setpoints
ZWave Install

Select button

Scroll

up

Scroll
down

Done

Select

User Settings

Set Clock
Filter Service
Maint Service
Screen Timeout

Select button

Scroll

up

Scroll
down

Set button

Scroll

up

Scroll
down

Back 

Set Clock

Set

Time     

 

10 

:15 AM

Date       3 / 23 / 09
Day        Mon

System Settings at Thermostat

Note: It may be necessary to go back and review 
step 6 in the installation section to verify the 
differences between the system types.

Menu
button

MENU   MODE     FAN       RUN

75

76 H
74 C

11:15 AM 

Two inner

buttons

Select button

Scroll

up

Scroll
down

+

 button

Done

Mechanical Settings

Select

Type        Heatpump
Fan Type          Elec
C/O Type      w/Cool
2nd Stage Heat    N

9

Electric Furnace Mechanical Settings

a.  Press the 

MENU button twice.

b.  Press and hold the two inner buttons for 3 seconds to view 

Installer Settings.

c.  Scroll down to 

System Settings and press the Select button.

d.  Scroll to 

Mechanical Settings (it is the fi rst option), then 

press the 

Select button.

e.  Scroll down to 

Fan Type .

f. 

Press the 

+ button to change the setting Electric

If Single Stage System, press 

Done 4 times and go to step 19.

If Multistage System, continue with steps “g” through “j”.

g.  Scroll down to 

2nd Stag

e Heat

.

h.  Press the 

+ button to change the setting to Y for Yes. 

i. 

If your system also has 2nd stage cooling, scroll down to  
2nd Stage Cool and Press the + button to change the setting 
to 

Y for Yes. 

j. 

Press the 

Done button 4 times and go to step 19.

18B

18C

Heat Pump 

Mechanical Settings

a.  Press the 

MENU button twice.

b.  Press and hold the two inner buttons for 3 seconds to view 

Installer Settings.

c.  Scroll down to 

System Settings and press the Select button.

d.  Scroll to 

Mechanical Settings (it is the fi rst option), then press 

the 

Select button.

e.  Scroll to system 

Type.

f. 

Press the 

button to change the setting to 

Heat Pump

g.  Scroll down to 

Fan Type .

h.  Press the 

+ button to change the setting Electric.

i. 

If Coleman, Rheem, or Rudd brand heat pump, scroll to 

C/O 

Type and change to 

With Heat

.

If Single Stage System, press 

Done 4 times and go to step 19.

If Multistage System, continue with steps “j” through “n”.

j. 

Scroll down to 

2nd Stag

e Heat

.

k.  Press the 

+ button to change the setting to Y for Yes. 

l. 

Scroll down to 

2nd Stage Cool.

m.  Press the 

+ button to change the setting to Y for Yes. 

n.  Press the 

Done button 4 times and go to step 19.

Gas Furnace - Multist

age Mechanical Settings

a.  Press the 

MENU button twice.

b.  Press and hold the two inner buttons for 3 seconds to view 

Installer Settings.

c.  Scroll down to 

System Settings and press the Select button.

d.  Scroll to 

Mechanical Settings (it is the fi rst option), then 

press the 

Select button.

e.  Scroll down to 

2nd Stag

e Heat

.

f. 

Press the 

+ button to change the setting to Y for Yes.

g.  If your system also has 2nd stage cooling, scroll down to  

2nd Stage Cool and Press the + button to change the setting 
to 

Y for Yes. 

h.  Press the 

Done button 4 times and go to step 19.

18A

T

est Heating Operation

 (if your system has heating)

a.  Press the 

MODE

 button.

b.  Scroll to 

HE

ATING

c.  Press the 

Done button to return to the home screen.

d.  Turn the temperature up using the scroll up button until the new setpoint is above the room temperature. 
e.  Verify that the heating system turns on and runs.

Note: It may take approximately 5 minutes for the system to start up after switching from COOLING to HEATING mode. 
There is a built in time delay which will not allow the equipment to turn on until it is ready. The screen will display the word 
“Wait” until the time delay has fi nished.

This concludes the system checkout.  If any part of your system fails to come on when performing this checkout 
procedure, verify that the correct wires were connected to the wall plate and that each wire is securely attached to the 
appropriate terminal. Also go back and verify that you have set up the Mechanical Settings to match your System Type.

10

Test F

an Operation

a.  Press the 

FAN button.

b.  Scroll to 

ON

.

c.  Verify that the system fan starts and moves air.
d.  Press the 

FAN button.

e.  Scroll to 

AUT

O

f. 

Press the 

Done button to return to the home screen.

T

est Cooling Operation

 (if your system has cooling)

a.  Press the 

MODE

 button.

b.  Scroll to 

COOLING

.

c.  Press the 

Done button to return to the home screen.

d.  Turn the temperature down using the scroll down button until the 

new setpoint is below the room temperature. 

e.  Verify that the outdoor unit and the system fan come on and run.

Perform System Checkout

19

FAN
button

MODE

button

MENU   MODE     FAN       RUN

75

76 H
74 C

11:15 AM

AUTO AUTO

Sys Off
Run

CA

UTION

Do not run the 

air conditioner if the outdoor 

temperature is below 55 degrees F.

19

(Continued)

Add Thermostat into 

the Home Control Network

20

Add the thermostat into the home control network.

Hold the Remote Control within 5 feet of the thermostat
throughout steps “b” through “f”.

a. 

Important Note: After you begin the pairing process, you have 

• 

30 seconds to complete the remainder of the steps. Study the steps 
below before beginning.

Press and release the plus 

b. 

(+) Device button on the Remote Control.

You will see a steady blinking blue LED on the on the Remote Control.
This means the Remote Control is in pairing mode.

Press the 

c. 

MENU button on the thermostat.

Scroll down to 

d. 

Z

-

Wave Install, and press the Select button.

Press the 

e. 

Yes button to pair the thermostat.

Observe the lights on the Remote Control.  The blue and red LEDs
will blink quickly to indicate the detection of a Z-wave device
being added.  Pairing is complete when the blue LED stays on
solid for 2 seconds to indicate success.

f. 

MENU   MODE     FAN       RUN

78

68 H
78 C

11:15 PM

MENU button

21

Verify enrollment of the thermostat.

Scroll down to 

a. 

Thermostat Info, and press the Select button.

Look at the number listed after 

b. 

ZNID.

If the number listed there is anything other than “000”, the 

• 

thermostat has been successfully enrolled.
If the number listed there is “000”, the thermostat has NOT 

• 

been successfully enrolled. In this case, repeat step 20 and 
verify again.

Press 

c. 

Done button 2 times when 

Select button

Done

Select

Menu Selection

User Settings
Usage Graph
ESM Setpoints
ZWave Install

Scroll
down

ZNID

Done

Thermostat Info

TZEMT400BB32    Ver: 01.00.10

ZVER:02.00.0             ZNID: 013

ZHID: 01.07.37.a7

System Type:          Standard

Fan Type:                Gas

22

Estab

lish Online Cont

rol of the Thermostat.

Please go to http//monitoringcontrol.verizon.com and follow the simple steps provided in the online setup wizard.  
This will enable you to add your Smart Thermostat device to the Home Control Network.

1

-

+

2