Страница 1: ...ualified installer service agency or the gas supplier EXPLOSION HAZARD Propane gas is heavier than air and may collect in any low areas or confined spaces In addition odorant fade may make the gas undetectable except with a warning device If the gas furnace is installed in a basement an excavated areas or a confined space it is strongly recommended to contact a gas supplier to install a gas detect...

Страница 2: ...g controls Their main function is to energize and de energize the heating or cooling circuit to maintain the temperature setting you select Many thermostats contain a room thermometer to indicate the approximate room temperature and a temperature scale to select the desired indoor air temperature In addition most thermostats have modes of HEAT OFF and COOL and fan modes of ON and AUTO When OFF is ...

Страница 3: ...he heating season In order for this unit to operate properly and safely the furnace needs air for both combustion and ventilation Accordingly observe the area in which the furnace is installed Check to make sure that all the air openings are unob structed Likewise insure that the spacing around the furnace itself is not blocked or obstructed 1 Set the thermostat to lowest setting 2 Turn offall ele...

Страница 4: ... 1600 5 33 0 08 2 4YC 060A 2000 6 67 0 08 Regular Owner Maintenance Never use combustible cleaning fluids on any part of the furnace You can perform some of the periodic maintenance functions for the unit yourself this includes replacing disposable or cleaning permanent the air filters cleaning the cabinet cleaning the condenser coil and conducting a general unit inspection on a regular basis Air ...

Страница 5: ...ion control 3 Check the burner manifold pressure A pressure tap is provided in the gas valve for this purpose 4 Visually inspect all of the unit s flue product passageways for excessive deposit buildup or corrosion If buildup or corrosion is apparent perform the necessary repairs 5 Arrange for a qualified service technician to inspect the unit every heating season to maintain safe and efficient op...

Страница 6: ...e Warrantor will furnish without charge a replacement heat exchanger Any local transportation related service labor and diagnosis calls are not included This limited warranty does not cover failure of your combination gas electric air conditioner if it is damaged while in your possession damage caused by unreasonable use of the combination gas electric air conditioner and or damage from failure to...

Страница 7: ...luded This limited warranty does not cover failure of your combination gas electric air conditioner if it is damaged while in your possession damage caused by unreasonable use of the combination gas electric air conditioner and or damage from failure to properly maintain the combination gas electric air conditioner as set forth in the Use and Care manual see Proper Maintenance section THE LIMITED ...

Страница 8: ...ducts covered under this warranty Warrantor shall not be obligated to pay for the cost of lost refrigerant No liability shall attach toWarrantor until products have been paid for and then liability shall be limited solely to the purchase price of the equipment under warranty shown to be defective THE WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES WHETHE...