XT300C DELUXE PROGRAMMABLE HEAT-COOL THERMOSTAT

9

69-1212—1

Pub. No. 18-HD25D1-3

Table 5. Installer Self-Test Options 

(Continued).

NOTE:

Press Time 

 to return to the previous test or Time 

 to advance to the next test.

NOTE:

To exit, press Time 

 or Time

  ▼

  ▼

 then Run Program.

Key to
Press

Test
Number

Description

Keyboard Operation Self-Test (60)

Time 

60   7

Enter  keyboard  operation  self-test.

Temp 

  

60   9

Increase test number displays.

Temp 

  

60   8

Decrease test number displays.

Day

60   11

Day test number displays.

Copy

60   12

Copy test number displays.

System
(select
models)

60   3

System test number displays.

Fan
(select
models)

60   10

Fan test number displays.

Set
Current
Day/Time

60   1

Set Current Day/Time test number displays.

Run
Program

60   15

Run Program test number displays.

Daylight
Time

60   19

Daylight Time test number displays.

Heat/
Cool
Settings

60   5

Heat/Cool Settings test number displays.

Wake

60   0

Wake test number displays.

Leave

60   14

Leave test number displays.

Return

60   16

Return test number displays.

Sleep

60   2

Sleep test number displays.

Filter

60   17

Filter test number displays.

i

60   13

Information test number displays.

Device Information Self-Test (70) -  Refer to following section.

Содержание XT300C

Страница 1: ...heck the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing...

Страница 2: ...inal screw 3 Push excess wire back into the hole 4 Plug the hole with nonflammable insulation to prevent drafts from affecting the thermostat WIRES THROUGH WALL WALL MOUNTING HOLES M15044 MOUNTING SCR...

Страница 3: ...E BETWEEN DAYLIGHT SAVINGS AND STANDARD TIME INCREASE TIME SETTING OR SCROLL FORWARD THROUGH INSTALLER SETUP AND SYSTEM TEST DECREASE TIME SETTING OR SCROLL BACKWARD THROUGH INSTALLER SETUP AND SYSTEM...

Страница 4: ...crease To scroll the Installer Setup numbers backwards press Time To exit the Installer Setup press Run Program CAUTION Equipment Damage Hazard Can cause permanent equipment damage Electric heat syste...

Страница 5: ...eat mode Heating cycle rate 4 5 5 5 cph recommended 3 6 or 9 cph not recommended 3 6 or 9 3 3 cph 6 6 cph 9 9 cph Cooling cycle rate 9 3 3 3 cph recommended 2 or 5 cph not recommended 2 or 5 2 2 cph 5...

Страница 6: ...5 the compressor will be on during call for heat Minimum On Time Cool 33 10 10 minute minimum on time for compressor 0 thru 15 Minimum number of minutes 0 thru 15 the compressor will be on during call...

Страница 7: ...ogram System Filter Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy M12954 Daylight Time AM DST Tue Set Day Time M12955 Run Program Aut...

Страница 8: ...Refer to Table 5 for the directions and results of the specific tests Fig 13 Display of all the segments of the LCD NOTE Press Time to advance to the next test and Time to go back to the previous tes...

Страница 9: ...splays Copy 60 12 Copy test number displays System select models 60 3 System test number displays Fan select models 60 10 Fan test number displays Set Current Day Time 60 1 Set Current Day Time test n...

Страница 10: ...ot come on Thermostat is not being powered Check for 24 Vac between R and W terminals Check if the circuit breaker is tripped reset the circuit breaker Check if the system fuse is blown replace the fu...

Страница 11: ...utes for the system to respond Enter Installer Setup number 39 Reconfigure minimum off time if required System selection is not set to Cool Set system selection to Cool Cool setpoint is above room tem...

Страница 12: ...AMMABLE HEAT COOL THERMOSTAT 69 1212 1 Pub No 18 HD25D1 3 69 1212 1 T C Rev 3 99 American Standard Inc Troup Highway Tyler TX 75711 9010 Printed in U S A on recycled paper containing at least 10 post...

Отзывы: