background image

22-1890-01 

5

General 

Data

Product Specifications

Model No.

 1

 

4TTX6042H1000A 4TTX6048H1000A 4TTX6049H1000A 4TTX6060H1000A 4TTX6061H1000A

Electrical Data V/Ph/Hz

 2

 

208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60  230/1/60

Min Cir Ampacity 

26 

28 

26 

34 

39

Max Fuse Size (Amps) 

45 

50 

45 

60 

60

Compressor 

CLIMATUFF

®

 - SCROLL  CLIMATUFF

®

 - SCROLL 

CLIMATUFF

®

 - SCROLL 

CLIMATUFF

®

 - SCROLL   CLIMATUFF

®

 - SCROLL

No. Used - No. Stages 

1-1 

1-1 

1-1 

1-1 

1-2 

RL Amps - LR Amps 

19.9 - 109 

21.8 - 117 

19.9 - 109 

26.4 - 134 

28.8 - 152.9

Outdoor Fan FL Amps 

0.93  

0.93 

1.00 

0.93 

2.8

Fan 

HP 

1/5 1/5 1/5 1/5 1/3

Fan Dia (inches) 

27.6 

27.6 

27.6 

27.6 

27.6

Coil 

Spine Fin™ 

Spine Fin™ 

Spine Fin™ 

Spine Fin™ 

Spine Fin™

Refrigerant 

R-410A 

7/00-LB/OZ 11/00-LB/OZ 11/9-LB/OZ 11/00-LB/OZ 12/9-LB/OZ

Line Size - (in.) O.D. Gas

 3

 3/4 

7/8 

7/8 

1-1/8 

1-1/8

Line Size - (in.) O.D. Liquid

 3

 

3/8 3/8 3/8 3/8 3/8

Dimensions H x W x D (Crated)  53.4 x 35.1 x 38.7 

57.4 x 35.1 x 38.7 

57.4 x 35.1 x 38.7 

57.4 x 35.1 x 38.7 

57.4 x 35.1 x 38.7

Weight - Shipping 

305 

352 

324 

354 

332

Weight - Net 

257 

302 

287 

304 

295

Start Components 

NO 

NO 

NO 

YES 

NO

Sound 

Enclosure  YES YES NO YES NO

Compressor Sump Heat 

NO 

NO 

NO 

NO 

NO

Optional Accessories:

 4

  

 

Anti-short 

Cycle 

Timer 

TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A 

Evaporator Defrost Control A/C 

AY28X079 

AY28X079 

AY28X079 

AY28X079 

AY28X079

Rubber Isolator Kit 

BAYISLT101 

BAYISLT101 

BAYISLT101 

BAYISLT101 

BAYISLT101

Crank Case Heater Scroll 

BAYCCHT301 

BAYCCHT301 

BAYCCHT301 

BAYCCHT301 

BAYCCHT301

Hard Start Kit Scroll 

BAYKSKT260 

BAYKSKT260 

BAYKSKT260

Extreme Condition Mounting Kit  BAYECMT001 

BAYECMT001 

BAYECMT004 

BAYECMT001 

BAYECMT004

Snow Leg - Base & Cap 4" High  BAYLEGS002 

BAYLEGS002 

BAYLEGS002 

BAYLEGS002 

BAYLEGS002

Snow Leg - 4" Extension 

BAYLEGS003 

BAYLEGS003 

BAYLEGS003 

BAYLEGS003 

BAYLEGS003

Seacoast 

Kit 

BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001

Refrigerant Lineset

 5

 

TAYREFLN7*

 

TAYREFLN3*

 

TAYREFLN3*

 

TAYREFLN4* TAYREFLN*4

1

  Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.

2

  Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.

3

  Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For 061 units, Max. linear length 60 ft.; Max. lift - Suction 25 ft.; Max lift - Liquid 25 ft.

 

For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0

. (

denotes latest revision) 

4

  For accessory description and usage, see page 5. 

5

  * = 15, 20, 25, 30, 40 and 50 foot lineset available.

Содержание XL16i

Страница 1: ...Split System Cooling Product Data XL16i 1 5 Tons PUB NO 22 1890 01 ...

Страница 2: ...fort R mode approved Glossy corrosion resistant finish Internal compressor high low pressure temperature protection 018 024 030 060 ship with start kit Compressor sump heat Liquid line filter drier Tarpaulin gray cabinet with anthracite gray badge and cap High pressure switch Demand defrost control with diagnostics Service valve cover R 410A refrigerant S E E T design testing 100 line run test Low...

Страница 3: ... 2 General Data 4 Product Specifications 4 A weighted Sound Power Level dB A 4 Accessory Description and Usage 5 AHRI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimensions 10 Mechanical Specification Options 11 ...

Страница 4: ...CHT300 BAYCCHT300 BAYCCHT301 Hard Start Kit Scroll BAYKSKT260 Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 BAYECMT001 BAYECMT001 Snow Leg Base Cap 4 High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg 4 Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Refrigerant Lineset 5 TAYREFLN850 TAYREFLN950 TAYREFLN7 TAYREFLN7 1 Cert...

Страница 5: ...ssories 4 Anti short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control A C AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Crank Case Heater Scroll BAYCCHT301 BAYCCHT301 BAYCCHT301 BAYCCHT301 BAYCCHT301 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260 Extreme Condition Mou...

Страница 6: ...mpressor recycling until 5 minutes have elapsed after satisfying call or power interruptions Use in area with questionable power deliv ery commercial applications long lineset etc Evaporator Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze up condi tions Used for low ambient cooling to 30 F with TXV Rubber Isolators 5 large rubber donuts ...

Страница 7: ...ctronic Filter Draft Inducer Speeds 1 Single Speed 2 Two Speed V Variable Speed Gas Furnaces G A M 5 A 0 B 3 6 M 3 1 S A A Brand T Better G Good Product Type A Air Handler Product Tier 2 Good Entry Level Feature Set 4 Better Retail Replacement Mid Effy 5 Better Entry Level High Effy Multi Speed 7 Best Retail Replacement High Effy Variable Speed 8 Best Retail Ultimate High Effy Variable Speed Major...

Страница 8: ... 2013 Trane 8 22 1890 01 4TTX6018H Electrical Data Schematic Diagrams SEE LEGEND Printed from D156722P01 ...

Страница 9: ...22 1890 01 9 4TTX6024H Electrical Data Schematic Diagrams SEE LEGEND Printed from D156722P01 ...

Страница 10: ...10 22 1890 01 4TTX6030H Electrical Data Schematic Diagrams SEE LEGEND Printed from D156722P01 ...

Страница 11: ...22 1890 01 11 Electrical Data Printed from D156910P01 4TTX6036H Schematic Diagrams SEE LEGEND ...

Страница 12: ...12 22 1890 01 Schematic Diagrams Printed from D156552P01 4TTX6042H Electrical Data ...

Страница 13: ...22 1890 01 13 Schematic Diagrams Printed from D156578P01v 4TTX6048H Electrical Data ...

Страница 14: ...14 22 1890 01 Electrical Data Schematic Diagrams Printed from D156677P01 4TTX6049H ...

Страница 15: ...22 1890 01 15 Electrical Data Schematic Diagrams Printed from D156974P01 4TTX6060H ...

Страница 16: ...16 22 1890 01 Electrical Data Schematic Diagrams 4TTX6061H Printed from D156678P02 ...

Страница 17: ...22 1890 01 17 LEGEND Schematic Diagrams Electrical Data ...

Страница 18: ... 86 3 3 8 730 28 3 4 4TTX6036H 4 1 1267 49 7 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 730 28 3 4 4TTX6042H 4 1 1267 49 7 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 730 28 3 4 4TTX6048H 4 1 1369 53 7 8 946 37 1 4 870 34 1 4 7 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 730 28 3 4 4TTX6049H 4 1 1369 53 7 8 946 37 1 4 870 34 1 4 7 8 3 8 152 6 98 3 7 8 219 8...

Страница 19: ...nd high pressure switch High and low pressure controls are inherent to the compressor A factory installed liquid line drier is standard Compressor The Climatuff compressor features internal over temperature and pressure protection and total dipped hermetic motor Other features include centrifugal oil pump and low vibration and noise Condenser Coil The outdoor coil provides low airflow resistance a...

Страница 20: ...rder Number File Number Supersedes Stocking Location The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice 05 13 ...