SAFETY WARNING

Only qualified personnel should install and service the equipment. The installation, starting up, and 
servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific 
knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could 
result in death or serious injury. When working on the equipment, observe all precautions in the literature 
and on the tags, stickers, and labels that are attached to the equipment. 

Wireless Comm

November 2012

BAS-SVX40A-EN

WCI

WCI

WCI

WCI

WCI

WCI

WCI

WCI

WCI

WCI

WCI

WCI

WCI

WCI

Installation, Operation, 
and Maintenance

Содержание Wireless Comm

Страница 1: ...nowledge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the l...

Страница 2: ...n at any time and to make changes to its content without obligation to notify any person of such revision or change Trademarks All trademarks referenced in this document are the trademarks of their re...

Страница 3: ...Applications 12 Repeater Applications 16 Establishing the Network 17 WCI LEDs and Buttons 17 Three Ways to Establish a Wireless Network 19 Establishing the Network After Tracer SC Installation 19 Est...

Страница 4: ...ppendix Using the Tracer TU Service Tool with Wireless Networks 27 Requirements for Joining 27 Joining Tracer TU with a Wireless Network 27 Managing a Wireless Network and Devices 29 Connecting to a D...

Страница 5: ...er SC see Mounting and Wiring the WCI p 12 and Figure 6 p 14 Automatic Network Formation When a WCI is connected to a Tracer SC it is auto assigned as the coordinator To enable the coordinator Tracer...

Страница 6: ...ion of X13790902 no wiring harness no installation instructions For factory ordering in bulk X13641194 Outdoor enclosure to protect WCI from harsh environments or wet indoor environments Part number D...

Страница 7: ...Equipment FCC CFR47 Sec 15 247 subpart E Digital Modulation Transmission with no SAR FCC ID TPF 251701 This device complies with part 15 of the FCC Rules Operation is subject to the following two cond...

Страница 8: ...ommunications radio lectriques ou de t l vision ceci pouvant tre d termin en allumant et en teignant l quipement l utilisateur est encourag essayer de corriger l interf rence en utilisant un ou plusie...

Страница 9: ...location is outside of the rooftup or air handling unit In outdoor locations the WCI should be mounted inside of a plastic enclosure suitable for outdoor use Kele PS 1811 9 and TK 1811 are recommended...

Страница 10: ...roup refers to all of the networks that communicate with the same Tracer SC 2 Set the right NET rotary address switch for each WCI that is to be on the same network to an identical number If there are...

Страница 11: ...address are within radio range of each other Addresses above 127 may be used for Wireless Comm systems see Wireless Comm Network Design Best Practices Guide BAS SVX55 for more information 3 Set the a...

Страница 12: ...er 3 Secure the backplate to the mounting surface using appropriate hardware M3 5 x 20 mm self drilling screws are provided 4 Attach the 4 connector screw terminal block on the wiring harness to the r...

Страница 13: ...a controller cannot exceed 656 ft 200 m If the wiring harness does not provide enough length use 18 AWG 24 pF ft max communication wire Trane purple wire To wire the WCI to a Tracer SC see Figure 6 p...

Страница 14: ...K 24VDC IMC IMC Ground 24 Vdc Gray LINK Blue LINK Black Ground Red 24 Vdc Connect both 2 connector screw terminal blocks to either of the IMC terminals on the PM014 WCI WCI WCI WCI WCI WCI WCI WCI Tra...

Страница 15: ...CI to a BCI R 24 VDC IMC LINK IMC LINK LINK 24 Vdc UC Gray LINK Blue LINK Black Ground Red 24 Vdc VAC 24 BI1 BI2 BI3 LINK IMC 24 VDC IMC Jumper LINK LINK 24 Vdc WCI BCI I Attach jumper at BI1 to enabl...

Страница 16: ...block on the wiring harness to the receptacle on the WCI Figure 4 5 Remove the blue IMC and gray IMC wires from the wiring harness 6 Connect the red 24 Vdc Vac wire and black ground wire through the...

Страница 17: ...NWK SNSR CRD RX LINK TX LINK DIAG PWR OPEN NET The green NWK LED illuminates on every WCI that has joined the network The yellow CRD LED illuminates on the coordinator WCI The START button On a networ...

Страница 18: ...he WCI Coordinator LED yellow CRD On solid WCI is network coordinator Open Net LED yellow OPEN NET On solid Network is open for joining Off Network is closed Reception LED yellow RX LINK Flickers Data...

Страница 19: ...twork 3 Observe the green NWK LED illuminate On the coordinator WCI indicating that it has joined its own network On each additional WCI as it joins the network Note Typically it takes about 10 minute...

Страница 20: ...and wiring instructions see WCI Addressing p 10 and Mounting and Wiring the WCI p 12 After power is restored to the Tracer SC the WCI that is installed on the Tracer SC automatically becomes the netw...

Страница 21: ...Figure 13 Wireless zone sensor receiver association Notes To observe the radio signal strength between the sensor and receiver press the Test button on the sensor For more information about the wirel...

Страница 22: ...network 2 Observe the green NWK LED illuminate on a WCI that joins the network Adding Additional Coordinators to a Tracer SC A Tracer SC can have a total of eight WCIs installed on it Each WCI instal...

Страница 23: ...control of the unit controller To remove a coordinator WCI change its rotary address setting Replacing a WCI on a Network See Replacing a Failed WCI p 25 Closing the Network To prevent WCIs from joini...

Страница 24: ...ange or too many obstacles Relocate WCI Defective WCI Replace Possible cause Explanation Resolution No power to the WCI Ensure that the WCI is wired properly to the Tracer SC Wireless link on the Trac...

Страница 25: ...Possible cause Explanation Resolution Power loss If power loss causes communication to be lost the coordinator WCI will re initiate the network as soon as power is returned Signal obstruction If an o...

Страница 26: ...Tracer SC is present 10 Set or verify if pre addressed the rotary address switches on the new WCI 11 Attach the terminal block on the wiring harness to the receptacle on the new WCI and route the wir...

Страница 27: ...k p 22 Requirements for Joining The requirements for joining Tracer TU to a wireless network are Tracer TU version 8 2 minimum The Tracer TU Communications Adapter installed on the service tool laptop...

Страница 28: ...s Network Utilities 4 Select the network you want Tracer TU to join Click the Join button Note Tracer TU can join only one network at a time 5 If a Tracer SC is present on the network a log in prompt...

Страница 29: ...it by connecting to a device on the network Connecting to a Device To connect to a device 1 From the Wireless Network Utilities screen select the Network Devices tab Figure 17 Figure 17 Network Devic...

Страница 30: ...functions are available to the connected device See Figure 19 Figure 19 Wireless menu List Devices An alternate way to view the Network Devices tab see Figure 17 Network Details Opens the Network Det...

Страница 31: ...evice from the network Only available when TU is attached to a unit controller that belongs to the network Disband Network Select to disband the network Note Tracer TU must be attached to the network...

Страница 32: ...matically The wireless sensor enable disable setting in the Setup Parameters screen is enabled checked by default However if a wired sensor is connected to the unit controller but a wireless sensor is...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...olio of advanced controls and HVAC systems comprehensive building services and parts For more information visit www Trane com Trane has a policy of continuous product and product data improvement and...

Отзывы: