Performance
Data
UNT-PRC001-EN
23
Four-Pipe
Coils
Table PD-10. Free Discharge Motor, Four-Pipe, Group 3
Cooling
Heating
CFM
TMBH
SMBH
GPM
WPD
TMBH
GPM
WPD
115V
230V
277V
FC
Coil
(L/s)
(TkW)
(SkW)
(L/s)
(kPa)
(TkW)
Q/ITD
(L/s)
(kPa)
Watt
Watt
Watt
2
2C1H
188 (89)
4.7 (1.4)
3.5 (1.0)
0.97 (0.06)
5.4 (16.2)
7.6 (2.2)
.07
0.51 (0.03)
0.6 (1.9)
60
95
65
2C2H
177 (84)
4.5 (1.3)
3.4 (1.0)
0.93 (0.06)
5.1 (15.1)
12.7 (3.7)
.12
0.85 (0.05)
3.2 (9.7)
60
95
65
3C1H
177 (84)
6.3 (1.8)
4.3 (1.3)
1.29 (0.08)
13.4 (40.1)
7.3 (2.1)
.07
0.48 (0.03)
0.6 (1.8)
60
95
65
3
2C1H
260 (123)
6.1 (1.8)
4.5 (1.3)
1.28 (0.08)
9.8 (29.2)
10.4 (3.1)
.09
0.69 (0.04)
1.3 (3.8)
85
89
101
2C2H
242 (114)
5.9 (1.7)
4.3 (1.3)
1.23 (0.08)
9.1 (27.2)
17.2 (5.1)
.16
1.15 (0.07)
6.2 (18.6)
85
89
101
3C1H
242 (114)
6.9 (2.0)
5.1 (1.5)
1.45 (0.09)
3.4 (10.2)
9.9 (2.9)
.09
0.66 (0.04)
1.2 (3.4)
85
89
101
4
2C1H
320 (151)
7.7 (2.2)
6.0 (1.8)
1.60 (0.10)
3.4 (10.1)
13.5 (4.0)
.12
0.90 (0.06)
2.3 (7.0)
100
107
106
2C2H
304 (144)
7.4 (2.2)
5.8 (1.7)
1.55 (0.10)
3.2 (9.5)
21.4 (6.3)
.19
1.43 (0.09)
2.3 (6.9)
100
107
106
3C1H
304 (144)
10.3 (3.0)
7.2 (2.1)
2.12 (0.13)
7.7 (23.1)
13.1 (3.8)
.12
0.87 (0.05)
2.2 (6.6)
100
107
106
6
2C1H
508 (240)
13.4 (3.9)
9.9 (2.9)
2.76 (0.17)
11.0 (32.8)
21.6 (6.3)
.20
1.44 (0.09)
6.9 (20.6)
125
130
124
2C2H
483 (228)
13.0 (3.8)
9.6 (2.8)
2.68 (0.17)
10.4 (31.1)
34.3 (10.0)
.31
2.28 (0.14)
6.5 (19.4)
125
130
124
3C1H
483 (228)
14.4 (4.2)
10.7 (3.1)
2.97 (0.19)
3.8 (11.5)
20.8 (6.1)
.19
1.39 (0.09)
6.5 (19.4)
125
130
124
8
2C1H
623 (294)
14.1 (4.1)
11.3 (3.3)
2.90 (0.18)
3.2 (9.7)
27.2 (8.0)
.25
1.81 (0.11)
12.5 (37.5)
120
123
133
2C2H
596 (282)
13.7 (4.0)
11.0 (3.2)
2.81 (0.18)
3.1 (9.2)
41.6 (12.2)
.38
2.77 (0.17)
2.7 (8.1)
120
123
133
3C1H
596 (282)
18.6 (5.5)
13.1 (3.8)
3.80 (0.24)
6.8 (20.2)
26.4 (7.7)
.24
1.76 (0.11)
11.9 (35.5)
120
123
133
10
2C1H
835 (394)
20.6 (6.0)
15.8 (4.6)
4.27 (0.27)
7.4 (22.1)
36.2 (10.6)
.33
2.41 (0.15)
25.2 (75.3)
225
237
230
2C2H
796 (376)
20.0 (5.9)
15.2 (4.5)
4.15 (0.26)
7.0 (20.9)
55.8 (16.3)
.51
3.72 (0.23)
5.2 (15.4)
225
237
230
3C1H
796 (376)
25.6 (7.5)
17.8 (5.2)
5.28 (0.33)
13.9 (41.4)
35.1 (10.3)
.32
2.34 (0.15)
23.8 (71.0)
225
237
230
12
2C1H
923 (436)
24.6 (7.2)
18.1 (5.3)
5.06 (0.32)
10.9 (32.5)
41.1 (12.0)
.37
2.74 (0.17)
35.9 (107.2)
220
230
239
2C2H
876 (413)
23.8 (7.0)
17.5 (5.1)
4.91 (0.31)
10.3 (30.7)
63.0 (18.5)
.57
4.20 (0.26)
6.9 (20.6)
220
230
239
3C1H
876 (413)
28.1 (8.2)
19.8 (5.8)
5.76 (0.36)
10.0 (29.7)
39.6 (11.6)
.36
2.64 (0.17)
33.6 (100.4)
220
230
239
Table PD-11. Free Discharge Motor, Four-Pipe, Group 4
Cooling
Heating
CFM
TMBH
SMBH
GPM
WPD
TMBH
GPM
WPD
115V
FC
Coil
(L/s)
(TkW)
(SkW)
(L/s)
(kPa)
(TkW)
Q/ITD
(L/s)
(kPa)
Watt
3
2C1H
270 (128)
6.3 (1.9)
5.0 (1.5)
1.26 (0.08)
2.2 (6.6)
12.0 (3.5)
.11
0.80 (0.05)
1.9 (5.7)
86
2C2H
250 (118)
5.9 (1.7)
4.7 (1.4)
1.18 (0.07)
2.0 (5.8)
18.3 (5.4)
.17
1.22 (0.08)
1.7 (5.1)
86
3C1H
250 (118)
7.3 (2.1)
5.1 (1.5)
1.46 (0.09)
4.0 (11.9)
11.3 (3.3)
.10
0.75 (0.05)
1.7 (5.1)
86
4
2C1H
350 (165)
10.0 (2.9)
7.1 (2.1)
1.99 (0.13)
6.1 (18.2)
16.3 (4.8)
.15
1.09 (0.07)
4.2 (12.6)
98
2C2H
320 (151)
9.2 (2.7)
6.5 (2.0)
1.83 (0.12)
5.2 (15.7)
24.4 (7.2)
.22
1.63 (0.10)
3.5 (10.5)
98
3C1H
320 (151)
8.9 (2.6)
6.6 (1.9)
1.79 (0.11)
1.5 (4.5)
15.1 (4.4)
.14
1.01 (0.06)
3.7 (11.1)
98
6
2C1H
570 (270)
12.6 (3.7)
10.3 (3.0)
2.52 (0.16)
2.5 (7.5)
25.6 (7.5)
.23
1.70 (0.11)
11.2 (33.5)
105
2C2H
530 (250)
11.7 (3.4)
9.6 (2.8)
2.35 (0.22)
2.2 (6.6)
37.9 (11.1)
.34
2.53 (0.160)
2.3 (6.8)
105
3C1H
530 (250)
15.3 (4.5)
10.8 (3.2)
3.07 (0.19)
4.5 (13.6)
24.2 (7.1)
.22
1.61 (0.10)
10.2 (30.5)
105
Note:
1. Medium and low speed capacities are approximately 80 percent and 60 percent respectively of the high speed capacity.
2. Q/ITD = MBH (kW)/(Entering water temperature - Entering air temperature) when
∆
T and GPM (L/s) remain constant. To determine heating capacities at a different entering water
temperature or entering air temperature, compute the new ITD and multiply it by the Q/ITD shown.
ARI cooling performance is based on 80/67 F (27/19 C) entering air temperature, 45 F (7 C) entering chilled water temperature with
a 10 F (5.5 C) DT.
Heating performance is based on 70 F (21 C) entering air temperature, 180 F (82 C) entering hot water temperature with a
30 F (17 C) DT.
All performance measured on high speed tap, 115 V, zero ESP, with a throwaway filter. See page 18 for performance groupings.
Содержание UniTrane Fan-Coil
Страница 16: ...General Data UNT PRC001 EN 16 Piping Packages Automatic Circuit Setter C ...
Страница 77: ......
Страница 78: ......
Страница 79: ......