Treatment of drainage
If any problem will be caused due to the drainage of the outdoor unit (for example, the water
•
drained drops on the pedestrian), please execute the drainage pipe construction.
If drainage treatment is needed, a gap above 100mm must be provided under the air conditioner.
•
Drainage of the fi ttign pipe must be smooth during drainage construction (please note whether
•
there is water seepage when the fi tting pipe is taken out from the bottom).
Drainage pipe shall directly reach a horizontal plane along the wall, to avoid that the wall is
•
contaminated by the condensate water.
End of the drainage pipe will be avoided being put into water because there isn't elbow liquid
•
seal typically.
In order to make the system drainage to be easy, the drainage pipe shall incline downward, and
•
at least a 1:50 gradient will be provided to avoid water leakage.