Multistory installation (not exceeding 2 stories at most)
Multi-row installation
Space reserved for the outdoor unit must satisfy the distance required in the above drawing,
•
to guarantee the normal air outlet and heat dissipation of the condenser. Place of installation
must be provided with the minimum maintenance space requirement, for the convenience of
maintenance in future.
The outdoor shall not be installed in the place with direct sunlight as far as possible (if necessary,
•
a shelter not affecting air outlet of the unit should be provided).
Installation location of the outdoor unit shall be far away heat source, steam or infl ammable gas,
•
and running noise or hot air exhausted shall not infl uence the neighbors.
Don't install the outdoor unit in the place with strong wind or heavy dust.
•
Don't install the outdoor unit in the place where pedestrians often pass by the air outlet grille.
•
Installation location shall have enough strength to support the unit weight and the vibration
•
during running, also shall be placed horizontally. When the unit will be installed on the roof, it
shall confi rm whether the roof is strong enough, or with good water resistance.
Installation location of the unit shall be provided with good ventilation, to help the unit to
•
exchange heat better.
The unit shall not be exposed to rain as far as possible.
•
Length of the outdoor fi tting pipe and wire shall be within the permissible scope.
•