General Information

This manual describes proper installation, operation,
and maintenance procedures for air-cooled systems.
By carefully reviewing the information within this
manual and following the instructions, the risk of
improper operation and/or component damage will be
minimized. It is important that periodic maintenance be
performed to help assure trouble free operation.
Should equipment failure occur, contact a qualified
service organization with qualified, experienced HVAC
technicians to properly diagnose and repair this
equipment.

IIm

mp

po

orrtta

an

ntt:: All phases of this installation must comply

with the NATIONAL, STATE & LOCAL
CODES. In addition to local codes, the
installation must conform with National
Electric Code -ANSI/NFPA NO. 70 LATEST
REVISION.

Any individual installing, maintaining, or servicing this
equipment must be properly trained, licensed and
qualified.

IIm

mp

po

orrtta

an

ntt:: Do not remove the VFD without first

contacting technical support! For
performance-related questions and
diagnostic support in North America call 1-
877-872-6363. Any return requires a claim
number FIRST. Removal of the VFD prior to
this step will void the unit’s warranties.

Installation procedures should be performed in the
sequence that they appear in this manual. Do not

destroy or remove the manual from the unit. The
manual should remain weather-protected with the unit
until all installation procedures are complete.

N

No

otte

e:: It is not the intention of this manual to cover all

possible variations in systems that may occur or
to provide comprehensive information
concerning every possible contingency that may
be encountered during an installation. If
additional information is required or if specific
problems arise that are not fully discussed in this
manual, contact your local sales office.

Use the

“Installation Checklist,” p. 8

provided in this

manual to verify that all necessary installation
procedures have been completed. Do not use the
checklist as a substitute for reading the information
contained in this manual. Read this entire manual
before beginning installation procedures.

Unit Description

These condensers come with single and dual
compressor options. Single compressor outdoor units
feature a single refrigeration circuit requiring only one
set of refrigerant lines. Dual compressor/dual circuit
models give true stand-by protection; if one
compressor fails, the second will automatically start-
up. During light load conditions, only one compressor
will operate to save energy.

Содержание TWA0724-A Series

Страница 1: ...ing on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment March 2022 S SS SP P S SV VX X0 00 01 1D D E EN N Installation Ope...

Страница 2: ...r r p pr ro op pe er r P PP PE E f fo or r t th he e j jo ob b b be ei in ng g u un nd de er rt ta ak ke en n c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se er ri io ou us s i i...

Страница 3: ...u uc ct ti io on ns s b be el lo ow w c co ou ul ld d r re es su ul lt t i in n a an n e ex xp pl lo os si io on n w wh hi ic ch h c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se...

Страница 4: ...ng and Isolating Refrigerant Lines 21 Refrigerant Charging Procedure 22 Charging Levels 23 Liquid Charging 24 Electrical Wiring 24 Unit Power Supply 25 Low Voltage Wiring 25 Symbio Controls 25 Field W...

Страница 5: ...0Hz Digit 9 Refrigeration Circuit Stage A 1 Compressor 1 Line 1 Stage Single D 2 Compressors 2 Line 2 Stage Dual Digit 10 Major Design Sequence A Rev A B Rev B Digit 11 Minor Design Sequence A Rev A D...

Страница 6: ...s step will void the unit s warranties Installation procedures should be performed in the sequence that they appear in this manual Do not destroy or remove the manual from the unit The manual should r...

Страница 7: ...lt t i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y a an nd d e eq qu ui ip pm me en nt t o or r p pr ro op pe er rt ty y o on nl ly y d da am ma ag ge e T Te es st t l li if f...

Страница 8: ...see Weights p 16 The unit should be elevated on a level field fabricated four inch steel or wood 4 x 4 mounting frame Complete the frame and secure it into position before lifting the unit to the roof...

Страница 9: ...tremes in temperature Performed initial leak test Evacuated each refrigerant circuit to 500 microns Charged each circuit with proper amount of R 410A R 22 Electrical Wiring Provided unit power wiring...

Страница 10: ...in mm W in mm D in mm TWA0604DA 0724 A 0764DA 0904 A R 410A and TTA090 R 22 39 2 996 42 1 1070 36 3 922 TWA0604DD 0724 D 0764DD 0904 D R 410A 39 2 996 51 9 1317 39 3 999 TWA101 120 R 410A TWA120 R 22...

Страница 11: ...ONTROL WIRING OPTIONAL LINE VOLTAGE CONTROL WIRING SUCTION LINE LIQUID LINE BOTTOM OF UNIT 7 16 11 11 DIA ISOLATOR MOUNTING HOLES OUTSIDE HOLES 4 PLACES SERVICE PANEL SIDE SEE NOTE 4 HAIL GUARD OPTION...

Страница 12: ...S 4 PLACES SERVICE PANEL SIDE 50 7 8 1293 51 11 16 1312 WITH HAIL GUARD SEE NOTE 1 THIS HOLE FOR 7 5T ONLY REFRIGERANT GUAGE ACCESS CONTROL WIRING OPTIONAL SERVICE CLEARANCE 48 1219 2 SEE NOTE 2 FOR C...

Страница 13: ...NOTE 1 REFRIGERANT GUAGE ACCESS CONTROL WIRING OPTIONAL SERVICE CLEARANCE 48 1219 2 SEE NOTE 2 FOR CLEARANCE HAIL GUARD OPTIONAL HAIL GUARD OPTIONAL NOTES 1 ACCESS OPENING IS FOR FIELD INSTALLED BAYL...

Страница 14: ...IDE HOLES 4 PLACES SERVICE PANEL SIDE 50 7 8 1293 51 11 16 1312 WITH HAIL GUARD SEE NOTE 1 REFRIGERANT GUAGE ACCESS CONTROL WIRING OPTIONAL SERVICE CLEARANCE 48 1219 2 SEE NOTE 2 FOR CLEARANCE HAIL GU...

Страница 15: ...NEL SIDE BOTTOM OF UNIT SUCTION LINE REFRIGERANT GAUGE ACCESS LINE VOLTAGE LIQUID LINE CONTROL WIRING FRONT DETAIL A DIMENSIONAL DEATIL NOTES 1 MINIMUM CLEARANCE FOR PROPER OPERATION IS 36 914 4 FROM...

Страница 16: ...ble 2 TWA R 22 unit and corner weights lbs 60 Hz Tons Model No Shipping Max lbs Net Max lbs Corner Weights 1 2 3 4 7 5 TWA0902 A 397 360 112 105 74 69 10 TWA1202 A 482 437 110 129 91 107 15 TWA1802 D...

Страница 17: ...A072 090 120 TWA060 076 101 TWA0902 A 1202 A 1 2 3 4 LIFTING HOLES BOTH SIDES SERVICE ACCESS Figure 9 TWA180 240 TWA156 201 TWA1802 D TWA2402 D SERVICE ACCESS SERVICE ACCESS 1 2 3 4 LIFTING HOLES BOTH...

Страница 18: ...ble elevation difference TTA or TWA below indoor unit Acceptable liquid riser height based on total liquid line length below indoor unit Contact manufacturer for review N No ot te e Route refrigerant...

Страница 19: ...R Re ec co ov ve er r r re ef fr ri ig ge er ra an nt t t to o r re el li ie ev ve e p pr re es ss su ur re e b be ef fo or re e o op pe en ni in ng g t th he e s sy ys st te em m S Se ee e u un ni it...

Страница 20: ...Un ni it t D Da am ma ag ge e D Do o n no ot t a ap pp pl ly y h he ea at t t to o r re em mo ov ve e s se ea al l c ca ap ps s u un nt ti il l t th he e g ga au ug ge e p po or rt t c co or re es s...

Страница 21: ...e refrigerant charging hoses from liquid and gas gauge ports 9 Leak test the entire system Using proper procedures and caution as described in the previous section repair any leaks found and repeat th...

Страница 22: ...e the balance of the unit charge can be metered through a charging manifold set as liquid preferably through a schrader valve into the suction line to the compressor only while the compressor is runni...

Страница 23: ...04 B 11 8 11 8 0 5 1 2 1 125 1 1 8 TWA1014DA w TWE1014DA 27 3 N A 0 5 1 2 1 375 1 3 8 TWA1014DD w TWE1014DB 13 9 14 0 0 5 1 2 1 125 1 1 8 TWA1204 A w TWE1204 A 27 5 N A 0 5 1 2 1 375 1 3 8 TWA1204 D w...

Страница 24: ...e d di is sc co on nn ne ec ct ts s a an nd d d di is sc ch ha ar rg ge e a al ll l m mo ot to or r s st ta ar rt t r ru un n c ca ap pa ac ci it to or rs s b be ef fo or re e s se er rv vi ic ci in n...

Страница 25: ...Mount the indoor thermostat zone sensor or programmable zone sensor in accordance with the corresponding thermostat installation instructions Install color coded weather proof multi wire cable accordi...

Страница 26: ...g Refer to the latest version of Condenser and Air Handler Pairing guide SS SVN016 EN for instructions on field wiring connections Refrigerant Circuit Figure 15 Typical split system heat pump cooling...

Страница 27: ...ISCHARGE TEMPERATURE LIMIT DTL HIGH PRESSURE SWITCH HPCO DE ICE LOOP NOTE A CHECK VALVES 4 WAY SWITCHOVER VALVE LOW PRESSURE SWITCH LPCO EQUALIZER LINE NOTE A ONLY ONE OUTDOOR AND INDOOR COIL REFRIGER...

Страница 28: ...ompressor and the outdoor fans if suction pressure drops below the Low Pressure Cut Out setting Once the suction pressure has returned to normal the compressor and outdoor fans will cycle back on High...

Страница 29: ...y W Wh he en n i it t i is s n ne ec ce es ss sa ar ry y t to o w wo or rk k w wi it th h l li iv ve e e el le ec ct tr ri ic ca al l c co om mp po on ne en nt ts s h ha av ve e a a q qu ua al li if...

Страница 30: ...mbio Service and Installation mobile application The modes shown below can be initiated Depending on the equipment configuration the controller will energize the appropriate outputs A user selected ti...

Страница 31: ...ng maintenance inspections once per month Check unit wiring to ensure all connections are tight and that the wiring insulation is intact Inspect the condenser coils for dirt and debris If the coils ap...

Страница 32: ...32 SSP SVX001D EN inadvertently bent during the cleaning process M Ma ai in nt te en na an nc ce e...

Страница 33: ...or Superheat F at compressor Subcooling F at liquid line Dry Bulb Wet Bulb Suction Pressure Discharge Pressure Circuit 1 Circuit 2 Circuit 1 Circuit 2 C1 C2 C1 C2 Note Perform each inspection once per...

Страница 34: ...04 A 436766050001 436766270001 TWA0764DD TWE0764DB 436759340001 436759670001 TWA0904 D TWE0904 B 436759350001 436759680001 TWA1014DA TWE1014DA 436766080001 436766340001 TWA1204 A TWE1204 A 43676609000...

Страница 35: ...060 072 090 120 and Digit 9 A 1213 4183 Control Schematic Wiring Diagram for units with Dual compressor and Single Fan All TWA Units with Digit 4 6 060 072 076 090 and Digit 9 D 1213 4184 Control Sch...

Страница 36: ...or shipments outside the conterminous United States a replacement product or at the option of the warrantor parts for the repair of the product not conforming to this warranty and which have been retu...

Страница 37: ...SSP SVX001D EN 37 N No ot te es s...

Страница 38: ...38 SSP SVX001D EN N No ot te es s...

Страница 39: ...SSP SVX001D EN 39 N No ot te es s...

Страница 40: ...se visit trane com or americanstandardair com Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications wit...

Отзывы: