Condensate Drain Piping
,,,
,,,
,,,
yyy
yyy
yyy
Figure 5
Drain
1. The drain hose should come
straight down the wall to a level
where runoff will not stain the wall.
2. There should be no traps and avoid
putting the end of the hose in water.
3. To avoid damage to the floor or
furniture when the drain hose is
placed in the room, insulate the
hose with foamed polyethylene
or equivalent.
4. After completing refrigerant lines,
wining and drain connection, bind
the tubing, wining and drain pipe
(check if local codes permit it) into
a bundle by using tape at 100 or
200 mm (4 in. or 8 in.) intervals.
Make sure the drain tube is at the
bottom of the bundle (Figure 5).