background image

4

MS-SVN005-EN

Valid System Combinations

Table 1 : TTT/TTD Multi-Split Condensing Unit with Convertible,

  Concealed and Frio Hi-Wall (For Domestic Only) Indoor Unit

Model

Model

Nominal

50 Hz

60 Hz

Outdoor Unit

Indoor Unit

Capacity

Btuh

MCW509H

9,000

Yes

Yes

MCW509H

9,000

MCW509H

9,000

Yes

Yes

MCW512H

12,000

MCW512H

12,000

Yes

Yes

MCW512H

12,000

MCX512 or MCD512

12,000

Yes

Yes

MCX512 or MCD512

12,000

MCW509H

7,500

Yes

No

TTT521AB0E

MCW509H

7,500

MCW509H

7,500

MCW509H

9,000

Yes

Yes

TTT527AB0E/A10E

MCW509H

9,000

MCW509H

9,000

MCW509H

9,000

Yes

Yes

TTT530AB0E/A10E

MCW509H

9,000

MCW512H

12,000

MCW509H

9,000

Yes

Yes

TTT533AB0E/A10E

MCW512H

12,000

MCW512H

12,000

MCW518H

18,000

Yes

Yes

MCW518H

18,000

MCX518 or MCD518

18,000

Yes

Yes

MCX518 or MCD518

18,000

MCW512H

12,000

Yes

Yes

TTT536AB0E/A10E

MCW512H

12,000

MCW512H

12,000

MCX512 or MCD512

12,000

Yes

Yes

TTT536AB00/A100

MCX512 or MCD512

12,000

MCX512 or MCD512

12,000

MCX512 or MCD512

12,000

Yes

Yes

MCX524 or MCD524

24,000

MCW512H

12,000

Yes

Yes

MCW524H

24,000

MCW509H

9,000

Yes

Yes

TTT536DB0E/D10E

MCW509H

9,000

MCW518H

18,000

TTD518AB0E/A10E

TTD521AB0E/A10E

TTD524AB0E/A10E

TTD524AB00/A100

TTD536AB0E/A10E

TTD536AB00/A100

TTD536DB00/D100

TTD536DB0E/D10E

Содержание TTD 518 A10E

Страница 1: ...D 524 A10E TTD 524 A100 TTT 527 A10E TTT 530 A10E TTT 533 A10E 50 Hz Models Cooling Only TTD 518 AB0E TTD 521 AB0E TTD 524 AB0E TTD 524 AB00 TTT 521 AB0E TTT 527 AB0E TTT 530 AB0E TTT 533 AB0E TTD 536...

Страница 2: ...days of delivery and notify the dealer Warning Warnings are provided at appropriate places in this manual to indicate to installers operators and service personnel of potentially hazardous situations...

Страница 3: ...lid System Combinations 4 Installation Requirements 6 Location and Preparation of Units 7 Connection of Refrigerant Tubing 8 Condensate Drain Piping 9 System Evacuation and Purging 10 Electrical Insta...

Страница 4: ...9 000 MCW509H 9 000 MCW509H 9 000 Yes Yes TTT530AB0E A10E MCW509H 9 000 MCW512H 12 000 MCW509H 9 000 Yes Yes TTT533AB0E A10E MCW512H 12 000 MCW512H 12 000 MCW518H 18 000 Yes Yes MCW518H 18 000 MCX518...

Страница 5: ...000 MCW509K 8 600 Yes Yes TTT527AB0E A10E MCW509K 8 600 MCW509K 8 600 MCW509K 8 600 Yes Yes TTT530AB0E A10E MCW509K 8 600 MCW512K 11 000 MCW509K 8 600 Yes Yes TTT533AB0E A10E MCW512K 11 000 MCW512K 11...

Страница 6: ...r on each one to deepen vibration between units Wall thickness of copper tube should be 0 8 mm 0 0314 in Both tubes must be well insulated with proper insulation materials The length of wiring will de...

Страница 7: ...concrete pad with bolts not supplied to prevent abnormal noise and vibration 5 The concrete pad must be positioned a minimum of 200 mm 8 from any well and surrounding shrubbery 6 Minimum clearance on...

Страница 8: ...5 8 in Cut approximately 30 to 50 cm 12 in to 20 in longer than estimated tubing length Before flaring remember to fit the nut Ream with tube end downward to avoid copper scraps inside the tube Remov...

Страница 9: ...hose in water 3 To avoid damage to the floor or furniture when the drain hose is placed in the room insulate the hose with foamed polyethylene or equivalent 4 After completing refrigerant lines winin...

Страница 10: ...00 microns in one 1 minute then evacuation is incompleted or system is leaking Attach appropriate hose from manifold gauge to suction and liquid line valves service ports Attached center hose of mainf...

Страница 11: ...d size Note Each country has their own field wiring rules and regulations Be sure the installation complies with local electrical codes Nameplate ratings on indoor units are for one to one system inst...

Страница 12: ...12 MS SVN005 EN Wiring Diagram 220 240 1 50 Hz 200 240 1 60 Hz...

Страница 13: ...MS SVN005 EN 13 220 240 1 50 Hz 200 240 1 60 Hz...

Страница 14: ...14 MS SVN005 EN...

Страница 15: ...MS SVN005 EN 15...

Страница 16: ...16 MS SVN005 EN...

Страница 17: ...MS SVN005 EN 17 Dimensional Data Models 50Hz TTT521AB0EA...

Страница 18: ...527AB0EA TTT527A10EA TTT530AB0EA TTT530A10EA TTT533AB0EA TTT533A10EA TTD536AB0EA TTD536A10EA TTD536AB00A TTD536A100A TTT536AB0EA TTT536A10EA TTT536AB00A TTT536A100A TTD536DB00A TTD536D100A TTD536DB0EA...

Страница 19: ...MS SVN005 EN 19 Models 50Hz 60Hz TTD518AB0EA TTD518A10EA TTD521AB0EA TTD521A10EA TTD524AB0EA TTD524A10EA TTD524AB00A TTD524A100A...

Страница 20: ...ions without notice Literature Order Number MS SVN005 EN 0601 Supersedes MS SVN005 EN 0300 Stocking Location Bangkok Thailand Trane Thailand 7th Floor Ploenchit Center Building 2 Sukhumvit Road Klongt...

Отзывы: