WHAT TO DO IF YOU SMELL 

GAS:  

•  Do not try to light any appliance.  
•  Do not touch any electrical switch; do 

not use any phone in your building.  

•  Immediately call your gas supplier 

from a neighbor’s phone. Follow the 
gas supplier’s instructions.  

•  If you cannot reach your gas supplier, 

call the fi re  department. 

 -  Installation and service must be per-

formed by a qualifi ed  installer, service 
agency, or  the gas supplier.    

 

FOR YOUR SAFETY  

 

WARNING:

 If the information in these instructions 

is not followed exactly, a fi re or  explosion may result 
causing  property damage, injury, or death.

Do not store or use gasoline or other fl ammable vapors or 
liquids in the vicinity of  this or any other appliance.  

This product must be installed and serviced by authorized 
personnel, qualifi ed in pool/spa heater installation.  Im-
proper installation and/or operation can create carbon 
monoxide gas and fl ue gases that can cause serious injury, 
property damage, or death.

Содержание TR250

Страница 1: ...re department Installation and service must be per formed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage injury or death Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance This prod...

Страница 2: ...nsumer Operation Maintenance 8 Maintaining proper water chemistry 8 Lighting Operating instructions label 10 Temperature adjustment 11 Temperature Lock out 12 Fahrenheit versus Celsius 12 Winterization 12 Spring start up 12 Error codes 13 Warranty 15 CONTENTS ...

Страница 3: ...o be used with spas Do NOT use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly recommended ...

Страница 4: ...hrough an unprotected suction outlet sump or suction outlet cover which is damaged broken cracked missing or unsecured can result in evisceration disembowelment Mechanical Entrapment There is potential for jewelry swimsuit hair decorations finger toe or knuck le to be caught in an opening of a suction outlet or suction outlet cover resulting in mechanical entrap ment WARNING To reduce the risk of ...

Страница 5: ...ing pool and spa water circulation system all system and pump controls must be in off position and filter manual air relief valve must be in open position Before starting system pump all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve position while system pump is running Before starting system pump fully open filter manua...

Страница 6: ...h the advice of a physician Always stir pool spa water before entering the pool spa to mix in any hot surface layer of water that might exceed healthful temperature limits and cause injury Do not tamper with controls because scalding can result if safety controls are not in proper working order 7 Persons with a medical history of heart disease circulatory problems diabetes or blood pressure proble...

Страница 7: ...the original purchaser repair or at our option replace without charge any defective part We further warrant that if the heat exchanger or exchanger headers water containing section leak within one year from date of such installation for all users due to defects in materials and workmanship we will provide a replacement part Cost of freight installation fuel and service labor after one year is at u...

Страница 8: ... pool water changes daily due to the addition of pool and sanitizing chemicals bather loads rain runoff and the amount of sun to name a few Improper chem istry balance and mineral content can cause scaling and deposits to form on pool walls in the filtration system in the heat exchanger tubes and additionally can promote corrosive action to all metals in the water path Chang ing spa water regularl...

Страница 9: ...tion requirements shown in the installation manual on page 26 5 BYPASS Until water chemistry is properly balanced and if your piping has a bypass valve installed for the heater open the bypass so that corrosive and potentially damaging water will not flow through the heater and there fore the heat exchanger Close the bypass valve once the water is properly balanced Failure to close the bypass valv...

Страница 10: ...10 Figure 2 Lighting Operating Instructions label ...

Страница 11: ...mperature setting is being displayed adjusted When the numeric display is not flashing the actual water temperature is being displayed The temperature settings for both SPA and POOL modes are initially set at the factory to 65 F The minimum allowed settings for SPA and POOL modes are both 65 F The maximum allowed settings for SPA and POOL modes are adjustable up to 104 F using the temperature lock...

Страница 12: ...played in Fahrenheit or Celsius TO change the display use the MODE button to place the heater in STANDBY Then press and hold the UP and MODE buttons until the display shows the F C selection Press the DOWN button to toggle between selections To accept the selection press the MODE button If the user does not act the selection will be automatically accepted after 60 seconds WINTERIZATION In moderate...

Страница 13: ...d control will run blower for 5 s then automatically restart after 2 minutes PF Electrical supply wiring error This code will display if 120V polarity is reversed low voltage is detected or if the ground path is not sufficient Reset is immediate after error is corrected AO Blower vacuum switch open error If the blower prover switch does not close after the blower starts the control will stop the i...

Страница 14: ...ormal operation resumes when temperatures stabilize If this condi tion is detected 3 times in a one hour period the heater will lock out until the electrical power is cycled off and back on Sb Keypad button stuck closed error If one of the keypad buttons is closed or pressed for more than 30 s the error code will be displayed but the control will continue to function The error code will be cleared...

Страница 15: ...ent installation and maintenance and adhering to the requirements of the jurisdic tion where the product is installed There are no warranties which extend beyond the description on the face hereof We shall not in any event be held liable for any special indirect or consequential damages EXPENSE OF DELIVERY AND INSTALLATION Each pool heater or replacement part to be furnished under this warranty sh...

Страница 16: ... to state LIMITATION ON LIABILITY All intended representations have been expressly set forth in this document This warranty may not be extended by oral or any other additional representations written sales information drawings or other mal function is strictly limited to repair or replacement of the defective heater or part as provided herein and the manufacturer is not responsible hereunder for i...