Creating an Entry for Cables
Cables are connected from the bottom of the pedestal, through a metal gland plate, and into the cabinet. The gland plates must
be fitted to the unit to ensure the specified degree of protection.
1.
Open the mains cabinet and remove the nuts from the mains gland plate.
2.
Remove the mains gland plate.
3.
Open the motor cabinet and remove the nuts from the motor gland plate.
4.
Remove the motor gland plate.
5.
Use a sheet metal punch to create entry holes in the mains and motor plates. Refer to the gland plate dimensions in the
operating instructions.
Attaching the Unit to the Pedestal
WARNING
Heavy Object!
Failure to follow instructions below could result in unit dropping which could result in death or serious injury, and equipment
or property-only damage.
Ensure that all the lifting equipment used is properly rated for the weight of the unit being lifted. Each of the cables (chains or
slings), hooks, and shackles used to lift the unit must be capable of supporting the entire weight of the unit. Lifting cables
(chains or slings) may not be of the same length. Adjust as necessary for even unit lift.
NOTICE
Equipment Damage!
Failure to follow instructions below could result in equipment damage.
Do not carry or lift the unit by the discharge plate. Use only the hangar brackets located at each corner to carry or lift the unit.
1.
Lift the frequency converter and position it on the pedestal.
2.
Verify that there is 225 mm (9 in) top clearance for air exhaust.
3.
Verify that the air intake at the bottom front of the unit is not obstructed.
4.
Install an M8x60 mm bolt with lock washer and flat washer through the frame and into the threaded hole at each corner
of the base. To ensure correct IP21/IP54 enclosure protection, the M8x60 bolts must go through the frame. Install 4 bolts
per cabinet. Torque to 9.6 Nm (85 in-lb). See
5.
Install an M10x30 mm bolt with captive lock washer and flat washer through each corner of the base plate and into the
threaded hole in the base. Install 4 bolts per cabinet. Torque to 19 Nm (169 in-lb). See
.
6.
Reattach the mains and motor gland plates as shown in
Installation Instructions
Pedestal Kit for F-size Enclosures
TR200 Series
2
All rights reserved.
BAS-SVN021
B