TK 56701-1-IM-EN
37
Installation Procedures
IIm
mp
po
orrtta
an
ntt:: Safety precautions must be followed. Refer to U
Un
niitt IIn
nsstta
alllla
attiio
on
n H
Ha
azza
arrd
dss in the S
Sa
affe
etty
y P
Prre
ecca
au
uttiio
on
nss section
of this manual before proceeding.
P
Prre
effe
errrre
ed
d IIn
nsstta
alllla
attiio
on
n M
Me
etth
ho
od
d — Thermo King recommends the four (4) factory installed nut plates attached inside
the frame along with the correct length hex head grade 5 mounting bolts (installer supplied) be used when installing the
unit.
If your installation requires the nut plates be removed, see “
“A
Alltte
errn
na
atte
e IIn
nsstta
alllla
attiio
on
n M
Me
etth
ho
od
d”
” on the next page.
N
No
otte
e:: Do not install any compressible washers or other materials between the unit and the truck!
1. Position condensing unit into cargo box opening. Do not pull on the drain hoses or electrical wires during the
installation.
2. From inside the cargo box, insert four (4) correct length mounting bolts with four (4) 2.00” OD flat washers
(supplied) through the front wall of the box and into the unit’s mounting nuts.
a. Apply blue thread locker to all four (4) unit mounting bolts.
b. Tighten the mounting bolts evenly and then torque to 81.4 N•m (60 ft-lbs).
3. Disconnect and remove lifting bar and eyebolts from unit.
4. Install the exhaust extension tube pointing towards rear of truck and tighten securely.
Figure 22.
Typical Installation Shown
1
RCS1137-3
3
2
4