Installation - Refrigeration Hoses
IMPORTANT: All hose bends must maintain at least minimum bend radii with no kinks. See “Minimum Bend Radii” on page 35.
Condenser Module Connections
1. Liquid Line
•
Fabricate #6 hose from liquid line fitting on condenser module to
drier in refrigeration module.
•
Install female 90°, male 90° ORS fittings with O-rings and tighten
securely.
2. Discharge Line
•
Fabricate #8 hose from discharge fitting on condenser module to oil
separator fitting in refrigeration module.
•
Install female 90°, male 90° ORS fitting with O-rings and tighten
securely.
Evaporator Connections
3. Suction Line - REMOTE (Fresh Compartment)
•
Fabricate #16 hose from manifold fitting A to the large suction
fitting of the accumulator assembly on REMOTE evaporator.
IMPORTANT: The suction line for the REMOTE evaporator must
be attached only to manifold fitting A or severe damage to the
compressor will result!
•
Install 90° ORS fittings with O-rings and tighten securely.
4. Suction Line - HOST (Frozen Compartment)
•
Fabricate #12 hose from the suction fitting on the HOST
evaporator to the small suction fitting of accumulator assembly on
REMOTE evaporator.
•
Install #12 hose to the small fitting on the accumulator with
supplied straight ORS reducing fitting and O-ring and tighten
securely.
•
Route hose through rear access hole of REMOTE evaporator,
install O-ring and attach 90° ORS fitting onto suction line fitting
and tighten securely.
5. Liquid Line - HOST (Frozen Compartment)
•
Fabricate #6 hose from liquid injection fitting on the condenser
module to liquid fitting on HOST unit.
•
Install the supplied tee splice ORS fitting and a 90° ORS fitting.
•
Route hose through rear access hole of HOST evaporator, install
O-ring and attach 90° ORS fitting onto liquid line fitting and
tighten securely.
6. Liquid Line - REMOTE (Fresh Compartment)
•
Fabricate #6 hose from the liquid line tee fitting on the HOST
evaporator to the liquid line fitting on the REMOTE evaporator.
•
Install O-ring and attach ORS fitting onto tee splice fitting on the
HOST evaporator and tighten securely.
•
Route hose through rear access hole of REMOTE evaporator,
install O-ring and attach 90°ORS fitting onto liquid line fitting and
tighten securely.
7. Defrost Line - HOST Frozen Compartment
•
Fabricate #6 hose from oil separator tee fitting on the refrigeration
module to the HOST evaporator.
•
Install the supplied tee splice fitting and 90° ORS fitting.
•
Route hose through rear access hole of HOST evaporator, install
O-ring and attach ORS fitting onto defrost fitting and tighten
securely.
8. Defrost Line - REMOTE Fresh Compartment
•
Fabricate #6 hose from tee splice fitting on the HOST evaporator to
defrost fitting on REMOTE evaporator.
•
Route hose through rear access hole of REMOTE evaporator,
install O-ring and attach ORS fitting onto defrost line fitting and
tighten securely.
Содержание Thermo King ES300
Страница 12: ...11 Required Tools ...
Страница 18: ...17 Dimensions Condenser Module Mounting Holes ...
Страница 19: ...18 Dimensions HMI A 140 mm 5 50 in B 46 mm 1 80 in C 12 mm 50 in ...
Страница 20: ...19 BLANK PAGE ...
Страница 24: ...23 Installation 2 ES300 Evaporators Alternative Installation Method Preferred Installation Method ...
Страница 26: ...25 Installation Refrigeration Module Alternative Installation Method Preferred Installation Method ...
Страница 28: ...27 Installation Power Pack Module Alternative Installation Method Preferred Installation Method ...
Страница 30: ...29 Installation Condenser Module Preferred Installation Method Alternative Installation Method ...
Страница 38: ...37 Important Suction Line Routing and P Trap Formation NOT ACCEPTABLE From Unit ...
Страница 40: ...39 Installation Refrigeration Tubes to Compressor ...
Страница 46: ...45 System Leak Check and Evacuation ...
Страница 48: ...47 Installation Electrical Connections ...
Страница 50: ...49 Electrical Connections Evaporator s ...
Страница 52: ...51 Installation Standby Power Receptacle ...
Страница 54: ...53 Installation Drain Hoses REMOTE Evaporator HOST Evaporator Defrost Heater Wires ...
Страница 56: ...55 Installation HMI ...
Страница 62: ...61 System Charging AMOUNT OF REFRIGERANT PER MODEL Model 50 5 00 lbs ...