42
18-CE09D1-1E-EN
Twinning
TWINNING CONNECTION DIAGRAM
1 STAGE HEAT / 1 STAGE COOLING THERMOSTAT
1 STAGE HEATING
1 STAGE COOLING
THERMOSTAT
FURNACE NO. 1
FURNACE NO. 2
ISOLATION RELAY
R1
R1
1 STAGE ODU
(NO TRANSFORMER)
Y1
B
Y1
Y1
Y1
W1
W1
W1
R
R
R
G
G
G
B
B
B
NOTES:
1. BOTH FURNACES MUST BE POWERED FROM
THE SAME 115 VAC PHASE LEG AT THE CIRCUIT BREAKER.
2. TRANSFORMERS MUST BE IN PHASE.
- MEASURE THE VOLTAGE BETWEEN THE “R” TERMINALS
ON BOTH FURNACES, VOLTAGE SHOULD BE LESS THAN
10 VOLTS.
- IF GREATER, REVERSE THE LOW VOLTAGE ON ONE OF THE
TRANSFORMERS AND RECHECK.
3. HEATING AND COOLING AIRFLOW MUST BE THE SAME FOR
BOTH FURNACES.
TWINNING CONNECTION DIAGRAM
1 STAGE HEAT / 1 STAGE COOLING
(WITH TRANSFORMER) THERMOSTAT
1 STAGE HEATING
1 STAGE COOLING
THERMOSTAT
FURNACE NO. 1
FURNACE NO. 2
ISOLATION RELAY
(FIELD SUPPLIED)
ISOLATION RELAY
R1
R1
Y1
B
Y1
Y1
Y1
W1
W1
W1
R
R
R
G
G
G
B
B
B
NOTES:
1. BOTH FURNACES MUST BE POWERED FROM
THE SAME 115 VAC PHASE LEG AT THE CIRCUIT BREAKER.
2. TRANSFORMERS MUST BE IN PHASE.
- MEASURE THE VOLTAGE BETWEEN THE “R” TERMINALS
ON BOTH FURNACES, VOLTAGE SHOULD BE LESS THAN
10 VOLTS.
- IF GREATER, REVERSE THE LOW VOLTAGE ON ONE OF THE
TRANSFORMERS AND RECHECK.
3. HEATING AND COOLING AIRFLOW MUST BE THE SAME FOR
BOTH FURNACES.
From Dwg. 21B341337 Rev. 2
OUTDOOR UNIT
(WITH TRANSFORMER)
R
C
ISOLATION RELAY
(FIELD SUPPLIED)
ALTERNATE CONNECTION
Содержание S8B1A026M2PSAB
Страница 12: ...12 18 CE09D1 1E EN Outline Drawings Table 2 14 5 Width Cabinet ...
Страница 13: ...18 CE09D1 1E EN 13 Table 3 17 5 Width Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 14: ...14 18 CE09D1 1E EN Table 4 21 Width Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 15: ...18 CE09D1 1E EN 15 Table 5 24 5 Width Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Страница 57: ...18 CE09D1 1E EN 57 N No ot te es s ...
Страница 58: ...58 18 CE09D1 1E EN N No ot te es s ...
Страница 59: ...18 CE09D1 1E EN 59 N No ot te es s ...