Purge Cylinder Regeneration Program

Data Sheet

The following information is required to be sent along with a tank for regeneration.  In order
to ensure the proper “leak credit” for refrigerant is received, all information must be
included.  This information should be written on the nameplate and stickers on the tank,
purge, and chiller.

Technician Name and #
Sales Office
Tank Sequence Number (from sticker on bottom of
tank)
Empty Weight of Cylinder (from sticker on bottom
of tank)
Refrigerant type
Chiller Model Number (1

st

 12 digits)

Chiller Serial Number
Chiller Sales Order Number
Tank Order Number (or N/A), (From Nameplate)
Tank Model Number, (From Nameplate)
Tank Serial Number, (From Nameplate)
Purge minutes & date when tank was installed
Purge minutes & date when tank was removed
Purge Model Number
Purge Serial Number (or N/A)

Send Tank & Data Sheet (using supplied pre-paid label) to:
Trane Purge Cylinder Regeneration Program
350 Sunpac Court
Henderson, NV  89015

See PRG-IOM-3E for details on tank removal, packaging, shipping, and installation.

May 2001

Содержание Purifier Plus Purge

Страница 1: ...PRG IOM 3E Installation Operation Maintenance Purifier Plus Purge Emission Collection Canister...

Страница 2: ...on 3 Model Number Description 3 Warnings and Cautions 4 Literature History 4 About this Manual 5 Receiving 5 Installation 7 Tank Replacement 9 Return Instructions 10 Maintenance 11 Specifications 11 D...

Страница 3: ...4 Development Sequence A First Development Digit 5 6 Future Use Digit 7 Tank Origin 0 Trane 1 Out source Digit 8 Tank Type N New R Regenerated Digit 9 Refrigerant 1 R11 2 R123 3 R113 4 Generic R11 R1...

Страница 4: ...Manual revised to include Updated canister drawing PRG IOM 3D October 1998 Manual revised to include Deletion of Hazardous shipping form information Added Pressurized Tank Warning PRG IOM 3E October...

Страница 5: ...ges Use with other purges may result in a potential safety hazard and or damage to the purge due to partial restriction of the purge exhaust Receiving Upon receipt of the unit inspect the shipping car...

Страница 6: ...ts 3 8 OD refrigeration grade copper tubing Length determined by location of canister 4 Bolts Use when canister is bolted directly to chiller such as Option 3 in Figure 2 Figure 1 Purifier Plus Canist...

Страница 7: ...valves are included in the line they must be fully open during use 4 Install or modify the Change Purifier Plus Canister label Figure 4 on the Purifier Purge near the minute timer Add the applicable...

Страница 8: ...pump out timer value at installation plus appropriate value from Table 1 B Installation date plus 3 years Figure 5 Typical Unit Nameplate Order No Example Model No PRPA000N2A0 Serial No L93C02684 For...

Страница 9: ...the temperature and pressure of the carbon At typical equipment room temperatures the Purifier Plus canister will hold approxi mately 12 lbs of refrigerant If the current tank weight is any more than...

Страница 10: ...onfirm the items listed under replacement canister were received 2 Document It Record all information on the data sheet enclosed in this IOM and or on tank labels and return the completed sheet with t...

Страница 11: ...ize Including bracket 21 H X 13 W X 14 L Connection sizes Inlet 3 8 Male flare Outlet 3 8 Male flare Temperature Range Operating 40 to 120 F Shipping and Storage 40 to 150 F DO NOT PAINT THE TANK The...

Страница 12: ...Empty Weight of Cylinder from sticker on bottom of tank Refrigerant type Chiller Model Number 1st 12 digits Chiller Serial Number Chiller Sales Order Number Tank Order Number or N A From Nameplate Tan...

Страница 13: ...SV CAP PP PRG IOM 3E 1001 Supersedes PRG IOM 3D Stocking Location La Crosse The Trane Company Aftermarket Business Unit 3600 Pammel Creek Road La Crosse WI 54601 www trane com An American Standard Com...

Отзывы: