Installation
WARNING
Live Electrical Components!
During installation, testing, servicing
and troubleshooting of this product,
it may be necessary to work with live
electrical components. Have a
qualified licensed electrician or other
individual who has been properly
trained in handling live electrical
components perform these tasks.
Failure to follow all electrical safety
precautions when exposed to live
electrical components could result in
death or serious injury.
WARNING
Fire Hazard!
Do not use an extension cord with
this unit. Doing so may cause a fire.
CAUTION
Use Copper Conductors Only!
Unit terminals are not designed to
accept other types of conductors.
Failure to use copper conductors
may result in equipment damage.
Electrical Requirements
The PTAC can be powered by a
power cord connected to a receptacle
in the wall or in a subbase. It can also
be connected directly to the building
supply wires with a hard wire kit.
For U.S. approval, 265V units must
have a permanent wiring connection.
This requirement can be met either
by supplying a subbase for
concealed cord connection or by
direct wiring with the hard wire kit.
The power cord measures 60 inches,
with 56 inches usable from the point
where the cord exits the unit cabinet
and the attached plug.
Installation