background image

Introduction

ACC-SVN199E-EN

Copyright

This document and the information in it are the property of 
Trane, and may not be used or reproduced in whole or in 
part without written permission. Trane reserves the right 
to revise this publication at any time, and to make changes 
to its content without obligation to notify any person of 
such revision or change.

Trademarks

All trademarks referenced in this document are the 
trademarks of their respective owners. 

Revision History

Updated Connecting to RTEM drawing in Wiring 
Connection chapter.

WARNING

Follow EHS Policies!

Failure to follow instructions below could result in 
death or serious injury.

All Trane personnel must follow the company’s 
Environmental, Health and Safety (EHS) policies 
when performing work such as hot work, electrical, 
fall protection, lockout/tagout, refrigerant handling, 
etc. Where local regulations are more stringent than 
these policies, those regulations supersede these 
policies. 

Non-Trane personnel should always follow local 
regulations.

Содержание Power Exhaust Foundation BAYPWRX320

Страница 1: ...training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature an...

Страница 2: ...rdous situation which if not avoided could result in minor or moderate injury It could also be used to alert against unsafe practices NOTICE Indicates a situation that could result in equipment or pro...

Страница 3: ...cument are the trademarks of their respective owners Revision History Updated Connecting to RTEM drawing in Wiring Connection chapter WARNING Follow EHS Policies Failure to follow instructions below c...

Страница 4: ...Part 5 Installation 6 Standard Economizer 6 Low Leak Economizer Downflow Units Only 9 Close Out Installation 10 Wiring Connection 11 Power Wiring 11 Control Wiring 12 Standard Economizer 12 Low Leak E...

Страница 5: ...mage if possible The owner must provide reasonable evidence that the damage did not occur after delivery 6 Notify the carrier s terminal of damage immediately by phone and by mail Request an immediate...

Страница 6: ...ing instructions Unless specified otherwise disconnect all electrical power including remote disconnect and discharge all energy storing devices such as capacitors before servicing Follow proper locko...

Страница 7: ...g six screws secure the internal hood assembly built in Step 5 to side flanges of return opening See Figure 6 8 Apply gasket 14 to return opening around the dimples as shown in Figure 7 Figure 4 Botto...

Страница 8: ...t a time See Figure 9 12 Insert wire tie into closest hole in the economizer front panel and secure the power and control wires See Figure 9 13 Install power exhaust assembly onto the side of unit usi...

Страница 9: ...in Figure 13 5 Apply gasket to the power exhaust assembly as shown in Figure 14 Figure 12 Seal seams and corners Seal corners Seal along seam on both sides and at corners WARNING Hazardous Voltage w...

Страница 10: ...ake sure they are all water tight See Figure 16 8 Proceed to Wiring Connection p 11 for wire routing and connections Close Out Installation Once all the wiring connections are made replace the filter...

Страница 11: ...19 and Figure 20 4 Take the back panel off from the power exhaust remove the 4 wire harness connected and discard 5 Connect the supplied harness to respective exhaust fan relay XFR and capacitor exhau...

Страница 12: ...r controller Figure 21 Wiring connection power exhaust WARNING Hazardous Voltage w Capacitors Failure to disconnect power and discharge capacitors before servicing could result in death or serious inj...

Страница 13: ...Wiring Connection ACC SVN199E EN 13 Figure 23 JADE controller connections 162A BK W16 101AU W 157B R Power Exhaust 157C R EXH1 162A BK AUX1 157C R Low Leak Economizer Figure 24 Wiring diagram...

Страница 14: ...ned on when the indoor blower is running and the damper position is greater than the Power Exhaust setpoint Low Leak Economizer The Power Exhaust setpoint point at which the Power Exhaust is turned on...

Страница 15: ...Notes ACC SVN199E EN 15...

Страница 16: ...ations without notice We are committed to using environmentally conscious print practices Trane and American Standard create comfortable energy efficient indoor environments for commercial and residen...

Отзывы: