PTAC-PRC001-EN

4

Features and
Benefits

Energy Efficiency
Trane PTAC units and heat pumps are
among the most efficient in the industry,
with EERs of up to 11.6 and COPs of up
to 3.3. The efficient design of the PSC
motor and airflow pattern help to reduce
the energy consumption of the fan.
Packaged terminal heat pumps tend to
be more efficient than electric heat only.
In fact, operating savings may result in a
payback of less than one year. During
heating operation, refrigerant in the heat
pump runs in the reverse direction of the
cooling operation. The outside air is
cooled, thereby giving up heat to the
refrigerant in the heat pump.
This heat is then pumped back inside,
resulting in up to three Btu’s of heat for
every Btu of energy consumed.
During cooling operation, heat is
removed from the building as the air is
cooled. This heat proceeds through the
compression cycle and is ultimately
rejected to the outside air.
Energy-saving options available with
PTAC units include:

Front Desk Contact Point

Each unit has low voltage interface
capability with a field-supplied ON/OFF
switch. Turn off heating or cooling to
unoccupied rooms.

Fan Mode Switch

Select continuous fan operation or cycle
the fan ON and OFF with the compressor
or heat operation. The switch is
concealed to help prevent tampering by
unauthorized personnel.

Temperature Limiter

This unit-mounted mechanical control
allows guests to adjust in-room
temperature settings within a pre-
programmed range.

Reliability

These features help assure reliable
operation:

Freeze Protection

When the unit senses temperatures of
40°F or below, the unit activates the fan
motor and either the electric resistance
heater or the hydronic heater to help
prevent pipes or fixtures from freezing.
This also overrides front desk control of
the unit mounted or wall sensor.

Automatic Emergency Heat

Each unit automatically switches over to
electric resistance heat if for any reason
the heat pump compressor system fails
or if the heating load is greater than the
unit capacity.

Random Restart

Avoid troublesome power surges that
can damage electrical circuits. Each unit
has a random restart circuit to prevent all
units from restarting at one time after
power disruption.

Compressor Restart Delay

Extend compressor life. The unit
automatically delays any restart attempt
by three minutes to allow the refrigerant
pressures time to equalize.

Quiet Operation

State-of-the-art design and construction
provide a quiet environment for guests
to relax. Contributing to the quiet
operation of the unit are:
•An acoustically insulated bulkhead.
•Acoustical rubber-in-shear isolators

under the compressor.

•An isolated fan motor.

Operating sound levels are further
dampened when the unit is in the LOW
FAN mode of operation.

Comfort
Dehumidification and air filtration are
both factors affecting comfort. When the
air is dehumidified, occupants feel more
comfortable at higher temperatures.
Trane PTACs help maintain lower
humidity levels in rooms, without the
need for expensive add-on’s. Another
benefit is that dehumidification can help
extend the life of furniture, wall
coverings and fixtures.
When ventilation air is filtered, rooms
stay cleaner, longer. The hidden
ventilation air intake filters outside air to
reduce dust and pollen.

User-Friendly Controls

Controls are easy to read, understand
and activate.

Содержание Packaged TerminalAir Conditioners & Heat Pumps

Страница 1: ...PackagedT erminalAir Conditioners Heat Pumps PTAC PRC001 EN October 2000...

Страница 2: ...oners PTACs and heat pumps are ideally suited for offices apartments hotels motels and institutional homes Key benefits which make the units a wise choice are Energy efficiency Reliability Quiet opera...

Страница 3: ...efits Application Considerations Selection Procedure Model Number Description Performance Data Cool and Heat Performance Electric Power Power ConnectionWiring Dimension andWeights Mechanical Specifica...

Страница 4: ...mperatures of 40 F or below the unit activates the fan motor and either the electric resistance heater or the hydronic heater to help prevent pipes or fixtures from freezing This also overrides front...

Страница 5: ...seven inch depth one of the shallowest silhouettes in the industry today To inhibit tampering the front can be secured to the chassis with hidden screws Our unit s new stylish design and neutral color...

Страница 6: ...nelWall Installation PanelWall and BlockVeneer Installation On applications not requiring subbase or leveling legs unit may be flush mounted to floor Sleeve Installation Data Framing forWall Case Fram...

Страница 7: ...Door G Hydronic with Power Door J Power Door K Condensate Pump with PowerVent L Condensate Pump with Power Door Stock Style Models PTEC0701GCA PTEC0901GCA PTEC1201GCA PTEC1501GCA PTEC1501JCA PTHC0701G...

Страница 8: ...05 1110 1120 1120 1485 1505 1505 EER 11 5 11 5 11 5 11 2 11 2 11 2 10 7 10 7 10 7 9 3 9 3 9 3 Unit without Electric Heater Min Circuit Ampacity 2 4 4 0 4 0 3 6 5 1 5 1 4 4 7 3 7 3 5 7 8 4 8 4 7 4 cfm...

Страница 9: ...3 2 3 2 3 2 3 1 3 1 3 1 2 8 2 8 2 8 2 42 5500 5700 5700 7200 7300 7300 9800 10000 10000 12200 12300 12300 37 4900 5100 5100 6400 6500 6500 9000 9200 9200 11200 11300 11300 32 4300 4500 4500 5600 5700...

Страница 10: ...55 3280 34 8935 3060 34 73 80 10585 4790 45 10020 4580 46 9420 4365 46 8795 4145 47 85 10450 5875 56 9880 5665 57 9270 5445 59 8640 5230 61 75 11265 8715 77 10610 8410 79 9875 8070 82 9000 7675 85 61...

Страница 11: ...55 3480 36 9135 3260 36 73 80 10785 4990 46 10220 4780 47 9620 4565 47 8995 4345 48 85 10650 6075 57 10080 5865 58 9470 5645 60 8840 5430 61 75 11365 8815 78 10710 8510 79 9975 8170 82 9100 7775 85 61...

Страница 12: ...0 34 73 80 10480 4705 45 9920 4495 45 9315 4275 46 8690 4050 47 85 10345 5730 55 9775 5520 56 9165 5300 58 8535 5075 59 75 11165 8615 77 10510 8310 79 9775 7970 82 8900 7575 85 61 80 11120 10110 91 10...

Страница 13: ...0 3445 36 9035 3220 36 73 80 10680 4905 46 10120 4695 46 9515 4475 47 8890 4250 48 85 10545 5930 56 9975 5720 57 9365 5500 59 8735 5275 60 75 11365 8815 78 10710 8510 79 9975 8170 82 9100 7775 85 61 8...

Страница 14: ...4991 1 88 1 89 0 66 16596 15061 14068 12584 19212 16006 16165 13519 20173 17689 16999 15158 2 00 2 10 0 76 16751 15195 14199 12696 19268 16142 16212 13635 20387 17846 17179 15293 2 13 2 32 0 85 16884...

Страница 15: ...its without electric heaters is 15 amps Overcurrent protection on 265 volt models must be cartridge style time delay fuses included and factory installed on Trane chassis 4 Total watts for 7 000 and 9...

Страница 16: ...bottom of sleeve Bottom drain to be located by customer Drain kit shipped separate 4 Unit provides 20 percent outside air 5 Detachable cord ships attached to unit Cord can be removed for direct attac...

Страница 17: ...17 PTAC PRC001 EN Dimension and Weights Field Supplied Extension...

Страница 18: ...finished interior wall Notes 1 This kit completely encloses all plumbing and coils but still allows easy access to controls 2 The chassis can slide out for easy service without removing hydronic plum...

Страница 19: ...ct extension kit are possible options These kits transfer air from one room to another yet allow different air flows for the rooms airflow distribution can be adjusted from 65 45 to 80 20 FrontView Du...

Страница 20: ...ring installation Coils Coils will have rifled copper tubing expanded into rippled edge louvered aluminum fins Heat Pumps Heat pumps will include a changeover thermostat that senses an outside coil sw...

Страница 21: ...ingTerminals The LS IN terminals will provide a connection for a switch that can be added to close the circuit and lockout the compressor and electric heat when the power company or energy management...

Страница 22: ...be attached to the transition piece to carry up to 40 percent of the conditioned air to the adjoining room Powered OutsideVent and Damper Kit An optional power vent kit can be installed to increase cf...

Страница 23: ...urity Key Locks The installation of Trane s security key locks helps prevent tampering of the controls used to set temperature heating and cooling functions Locks are available for all PTAC models Rem...

Страница 24: ...ssor or connecting tubing which proves to be defective due to workmanship or materials Limited Second through FifthYear Warranty During the 2nd through 5th year Trane will provide free of charge funct...

Страница 25: ...formation contact your local distributor dealer local district office or e mail us at comfort trane com SinceTheTrane Company has a policy of continuous product and product data improvement it reserve...

Отзывы: