background image

TTA-R410A

5

General Information

TTA 075 JDF
TTA 100 JDF
TTA 120 JDF
TTA 150 JDF 
TTA 150 JD0G/00
TTA 180 JD0G/00

TTA B51 JDF
TTA B65 JDF

TTA 200 JD0G/00
TTA 240 JD0G/00

500

1102.3

462

116.5 256.8

116.5 256.8 114.5 252.4

114.5 252.4

109.0 240.3

109.0 240.3 107.0 235.9

107.0 235.9

106.0 233.7

106.0 233.7 104.0 229.3

104.0 229.3

96.5

212.7

96.5

212.7

94.5

208.3

94.5

208.3

101.5 223.2

43.4

95.4

65.9

144.9

42.3

93.1

95.6

210.8

34.7

76.5

85.6

188.7

24.1

53.1

75.8

167.1

32.4

71.4

49.2

108.5

31.6

69.7

66.2

145.9

27.8

61.3

42.8

94.4

27.2

60.0

34.1

75.2

14.6

32.2

22.3

49.1

14.0

30.9

32.1

70.7

13.8

30.4

21.0

46.3

13.1

28.9

1018.5

432

952.4

420

925.9

382

842.2

253

556.6

240

529.1

189

416.7

164

361.6

85

187.4

80

176.3

456

1005.3

444

978.9

396

873.0

264

580.8

259

571.0

201

443.1

171

377.0

91

200.6

86

189.6

Warning:

 open and lock unit disconnect to prevent injury or death from

electric shock or contact with moving parts before attempting any installation 
or maintenance.

!

on page 20-24

This manual covers the installation of
the 

TTAB51, TTAB65, TTA075, TTA100 

,TTA120 and TTA150 (Single Circuit)
TTA150, TTA180, TTA200 and TTA240
(Dual Circuit and Manifolded-
Compressor)

 system outdoor units.

Installation procedures should be
performed in the sequence that they
appear in this manual .

Do not destroy

 

or remove manual from the unit. 

The manual should remain weather-
protected with the unit until all 
installation procedures are complete.

Note:

 It is not the intention of this

manual to cover all possible
variations in systems that may
occur or to provide comprehensive
information concerning every possible
contingency that may be encountered
during an installation. If additional
information is requir

HGRULIVSHFL¿F

problems arise that are not fully
discussed in this manual, contact
your local Sales of

¿FH

Note: 

Warnings” and “

Cautions”

appear at appropriate places in this
manual. Your personal safety and
the proper operation of this machine
require that you follow them carefully.
The Company assumes no liability for
installations or servicing performed by

XQTXDOL¿HGSHUVRQQHO

Installation Checklist

An “Installation Checklist” is provided
at the end of the installation section
of this manual. Use the checklist to
verify that all necessary installation
procedures have been completed.
Do not use the  checklist as a
substitute for reading the information
contained in the manual. Read the
entire manual befor beginning

installation procedures.

Unit Inspection

Inspect material carefully for any
shipping damage. If damaged,
it must be reported to, and claims
made against the transportation
company. Compare the information
that appears on the unit nameplate
with ordering and submittal data to
insure the proper unit was shipped.
Available power supply must be
compatible with electrical

FKDUDFWHULVWLFVVSHFL¿HGRQ

component nameplates.
Replace damaged parts with
authorized parts only.

Inspection Checklist

To protect against loss due to
damage incurred in transit, complete
the following checklist upon receipt
of the unit.
• Inspect individual pieces of the

shipment before accepting the unit.
Check for obvious damage to the
unit or packing material.

• Inspect the unit for concealed

damage before it is stored and as
soon as possible after delivery.
Concealed damage must be
reported within 15 days. If con
sealed damage is discovered,
stop unpacking the shipment.
Do not remove damaged material
from the receiving location.
Take photos of the damage if
possible. The owner must
provide reasonable evidence that
the damage did not occur after
delivery.

• Notify the carrier’s terminal of

damage immediately by phone
and by mail. Request an immediate
joint inspection of the damage by
the carrier and the consignee.

• Notify the sales representative and

arrange for repair. Do not repair the
unit until the damage is inspected
by the carrier’s representative.

!

!

Содержание ODYSSEY TTA 051 JDF

Страница 1: ...altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are...

Страница 2: ...Design Sequence Fourth Design Sequence New Design 1 Fan New comp change Unit Hi Ambient Temp Fifth Design Sequence Q R S J F No Option Copper Fin Blue Fin Single Circuit Manifolded Compressor for TTA1...

Страница 3: ...recaution General Information Installation Refrigerant Piping Guidelines Refrigerant Charging and Evacuation General Data Refrigerant Circuit Electrical Wiring Dimensional Data Operation Maintenance T...

Страница 4: ...g leakage of water etc Be sure to cut off the main power in case of setting up the indoor electronic control P C board or wiring works It could cause an electri shock Any presence of foreign substance...

Страница 5: ...Cautions appear at appropriate places in this manual Your personal safety and the proper operation of this machine require that you follow them carefully The Company assumes no liability for installa...

Страница 6: ...to insure proper unit operation A Do not install the unit under a low overhang Condenser discharge clearance is not less than 2 5 mm Important Do not obstruct condenser discharge air This can result i...

Страница 7: ...TTA 150 200 Dual Circuit TTA B51 B65 Single Circuit TTA 075 100 Single Circuit Suction line Liquid line 1 1 8 inch sealed type L refrigerant tubing 1 2 inch sealed type L refrigerant tubing D Recommen...

Страница 8: ...d the gauge manifold Figure 2 Unregulated pressures can damage system components protect painted surfaces from excessive heat Heat can damage system components and the unit UPZO 6 Shut off nitrogen su...

Страница 9: ...8 60 6 30 13 89 6 30 13 89 6 10 13 45 5 40 11 90 6 75 14 88 6 75 14 88 13 50 29 76 12 60 27 78 12 20 26 90 10 30 23 81 TTA 100 JDF Tubing Sizes Additional Additional See Suction Liquid Tubing Length...

Страница 10: ...only as required to obtain correct head and suction pressure Check suction line superheat and condenser sub cooling to ensure the unit is operating properly 4 Disconnect all power to the unit 5 Remov...

Страница 11: ...mm 743 x804 x 781 743 x804 x 781 WEIGHT Crated Shipping kg 86 91 Uncrated Net kg 80 85 1 MCA Minimum Circuit Ampacity 2 CFM is rated with standard air dry coil PSC Holding Charge Hermetic Scroll Galv...

Страница 12: ...Inner groove Inner groove Inner groove Rows 2 2 2 2 Fin Type Uncoated Corrugate Fins per inch 16 16 16 16 Refrigerant Flow Control FAN Fan Type Propeller Propeller Propeller Propeller No used 2 2 2 2...

Страница 13: ...nner groove Inner groove Inner groove Inner groove Rows 2 2 2 2 Fin Type Uncoated Corrugate Fins per inch 16 16 16 16 Refrigerant Flow Control FAN Fan Type Propeller Propeller Propeller Propeller No u...

Страница 14: ...14 TTA R410A Refrigerant Circuit TTA B51 B65 JDF Single Circuit TTA 075 150 JDF Single Circuit TTA 150 240 JD00 Dual Circuit TTA 150 240 JD0G Manifolded Comp Figure 4A Figure 4B...

Страница 15: ...PVU VM KPZJVUULJ Z P JOLZ T Z JVTWS P O HSS HWWSPJHISL JVKLZ KPZJVUULJ Z P JO HUK SVJR PU VWLU WVZP PVU V WYL LU HJJPKLU HS WV LY HWWSPJH PVU HPS YL V KV ZV TH YLZ S PU WLYZVUHS PUQ Y VY KLH O K L V...

Страница 16: ...LINE ARE CIRCUIT IDENTIFICATION COMPRESSOR HTR 4 6 5 T1 T2 T3 TTA B51 B65 JDF SINGLE CIRCUIT WIRING DIAGRAM ELEMENTARY DIAGRAM 4 9 13 12 10 11 8 7 5 6 N 7A TERMINAL GROUND HTR 3 2 1 POWER SUPPLY 380V...

Страница 17: ...ON FIELD WIRING OPTION FACTORY WIRING DEVICES BY MFR 1TB TERMINAL BLOCK CONTROL CIRCUIT RELAY TIME DELAY 3 MIN THERMOSTAT RELAY CONTROL LOCKOUT CONTROL LOW PRESS CONTACTOR COMPRESSOR HEATER CRANKCASE...

Страница 18: ...MINAL BLOCK HIGH VOLTAGE 2HTR 8 9 10 T3 1TH 1PB 2PB 3M 1HTR 2HTR 2TR 1TR 1R 2R 1M 2M T1 T2 LEGEND 1LP 2LP FU 1HP 2HP FUSE 5 AMP 20 19 GRAPHIC ELECTRICAL STANDARDS RELAY CONTACTS CIRCUIT IDENTIFICATION...

Страница 19: ...B 2PB 4M CONTACTOR COMPRESSOR RELAY CONTROL LOCKOUT RELAY TIME DELAY 4 5 MIN RELAY TIME DELAY 3 MIN HEATER CRANKCASE SWITCH PUSH BOTTON FUSE 5 AMP CONTROL LOW PRESS CONTROL HIGH PRESS A1 A2 AUXILIARY...

Страница 20: ...INE CONNECTION FEMALE BLAZED DIA 7 8 C LIQUID LINE CONNECTION FEMELE BLAZED DIA 1 2 TTAB65 TTAB51 A ELECTRIC WIRING OUTLET B GAS LINE CONNECTION FEMALE BLAZED DIA 7 8 C LIQUID LINE CONNECTION FEMELE B...

Страница 21: ...TTA R410A 21 Dimensional Data TTA 075 100 120 JDF SINGLE CIRCUIT HORIZONTAL AND VERTICAL DISCHARGE...

Страница 22: ...22 TTA R410A Dimensional Data TTA 150 JDF SINGLE CIRCUIT HORIZONTAL AND VERTICAL DISCHARGE...

Страница 23: ...TTA R410A 23 Dimensional Data TTA 150 180 200 240 JD00 DUAL CIRCUIT...

Страница 24: ...24 TTA R410A Dimensional Data TTA 150 180 200 240 JD0G MANIFOLDED COMPRESSOR...

Страница 25: ...ge pressure exceeds the High Pressure Cut Out s setting Internal Overload Protector IOL This device is a current thermal actuated warp switch imbedded in the compressor motor windings If will shut off...

Страница 26: ...nnually Cooling Season The following maintenance procedures must be performed at the beginning of HDFK FRROLQJ VHDVRQ WR LQVXUH HI FLHQW unit operation Perform all of the monthly maintenance inspectio...

Страница 27: ...ning the unit by avoiding serious and costly breakdown S S S S S S Table 6 Troubleshooting Chart Refrigerant Circuit S S P S P h g i H o o T e r u s s e r P d a e H P S S S P S P P P S P P S P P P P P...

Страница 28: ...nd specifications without notice We are committed to using environmentally conscious print practices Trane by Trane Technologies NYSE TT a global climate innovator creates comfortable energy efficient...

Отзывы: