TTA-R410A

System Precautions

Safety Precautions

WARNING

CAUTION

• 

To prevent injury to the user or other people and property
damage, the following instructions must be followed.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to
property.

Incorrect operation due to ingnoring of instructions may
cause harm or damage. The seriousness is classified be
the following indications.

• 

WARNING

WARNING

CAUTION

CAUTION

• 

After reading this manual, be sure to keep it together with
the Owner Manual in a handy place on the customer’s site.

 

Do not install the unit by yourself (customer)

Install the unit securely in a place which can bear the
weight of the unit.

Incomplete installation could cause injury due to fire,
electric shock, the unit falling or leakage of water. Consult
the dealer from whom you purchased the unit or special
installer.

If the electrical cover in the indoor unit and/or the service
panel in the outdoor unit are not attached securely, it could
result in a fire or an electric shock due to dust water, etc.

When installed in an insufficient strong place, the unit
could fall causing injury.

It could cause a fire or an electric shock due to defective
contact, defective insulation, exceeding the permissible
current, etc.

Incomplete connecting and fixing could cause fire.

Attach the electrical cover to the indoor unit and the
service panel to the outdoor unit securely.

 

• 

Locations where there may be a leakage of combustible gases.

• 

The place is filled with oil.

• 

Beachfront location.

• 

The place that contain sulfuric acid, such as hot springs.

• 

The place where high frequency devices or wireless devices
are used.

 

 

Perform earthing.

Do not connect the earth wire to a gas pipe, water pipe,
lightning rod or telephone earth wire. Defective earthing
could cause an electric shock.

 

Be sure to use the part provided or specified parts for
the installation work.

The use of defective parts could cause an injury due to a
fire, an electric shock, the unit falling, leakage of water, etc.

 

Be sure to cut off the main power in case of setting up
the indoor electronic control P.C. board or wiring works.

It could cause an electri shock.

Any presence of foreign substance such as air can cause
abnormal pressure rise or an explosion.

 

The appliance shall be installed in accordance with
national wiring regulations.

 

Do not install the unit in a place where an inflammable
gas leaks.

If gas leak and accumulate in the area surrounding the unit,
it could cause an explosion.

 

 

 

Fasten a flare nut with a torque wrench as specified in
this manual.

 

 

If gas leak and accumulate in the area surrounding the unit,
it could cause an explosion.

 

 

Install a earth leakage breaker depending on the install-
ation place (Where it is humid).

Perform the drainage/piping work securely according
to the installation manual.

If a earth leakage breaker is not installed, it could cause an
electric shock.

 

   

 

Avoid to installing in places that may cause problems to unit.

If there is a defect in the drainage/piping work, water could
drop from the unit and household goods could be wet and
damaged.

 

 

When installing or relocating the unit, make sure that no
substance other than the specified refrigerant (R410A)
enters the refrigerant circuit.

 

 

Check that the refrigerant gas due not leak after install-
ation has completed.

 

Do not use intermediate connection of the power cord
or the extension cord and do not connect many 
devices to one AC outlet.

If refrigerant gas leaks indoors, and comes into contact
with the fire of a fan heater, space heater, stove, etc..
harmful substances will be generated.

Perform the installation securely referring to the install-
ation manual.

 

Incomplete installation could cause a personal injury
due to fire, electric shock, the unit falling or leakage of
water

Perform electrical work according to the installation
manual and be sure to use an exclusive circuit.

 

If the capacity of the power circuit is insufficient or there is
insufficient electrical work, it could result in a fire or an
electric shock.

 

Use the specified wires to connect the indoor and
outdoor units securely and attach the wires firmly to
the terminal block connecting sections so the stress
of the wires is not applied to the sections.

Содержание ODYSSEY TTA 051 JDF

Страница 1: ...altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are...

Страница 2: ...Design Sequence Fourth Design Sequence New Design 1 Fan New comp change Unit Hi Ambient Temp Fifth Design Sequence Q R S J F No Option Copper Fin Blue Fin Single Circuit Manifolded Compressor for TTA1...

Страница 3: ...recaution General Information Installation Refrigerant Piping Guidelines Refrigerant Charging and Evacuation General Data Refrigerant Circuit Electrical Wiring Dimensional Data Operation Maintenance T...

Страница 4: ...g leakage of water etc Be sure to cut off the main power in case of setting up the indoor electronic control P C board or wiring works It could cause an electri shock Any presence of foreign substance...

Страница 5: ...Cautions appear at appropriate places in this manual Your personal safety and the proper operation of this machine require that you follow them carefully The Company assumes no liability for installa...

Страница 6: ...to insure proper unit operation A Do not install the unit under a low overhang Condenser discharge clearance is not less than 2 5 mm Important Do not obstruct condenser discharge air This can result i...

Страница 7: ...TTA 150 200 Dual Circuit TTA B51 B65 Single Circuit TTA 075 100 Single Circuit Suction line Liquid line 1 1 8 inch sealed type L refrigerant tubing 1 2 inch sealed type L refrigerant tubing D Recommen...

Страница 8: ...d the gauge manifold Figure 2 Unregulated pressures can damage system components protect painted surfaces from excessive heat Heat can damage system components and the unit UPZO 6 Shut off nitrogen su...

Страница 9: ...8 60 6 30 13 89 6 30 13 89 6 10 13 45 5 40 11 90 6 75 14 88 6 75 14 88 13 50 29 76 12 60 27 78 12 20 26 90 10 30 23 81 TTA 100 JDF Tubing Sizes Additional Additional See Suction Liquid Tubing Length...

Страница 10: ...only as required to obtain correct head and suction pressure Check suction line superheat and condenser sub cooling to ensure the unit is operating properly 4 Disconnect all power to the unit 5 Remov...

Страница 11: ...mm 743 x804 x 781 743 x804 x 781 WEIGHT Crated Shipping kg 86 91 Uncrated Net kg 80 85 1 MCA Minimum Circuit Ampacity 2 CFM is rated with standard air dry coil PSC Holding Charge Hermetic Scroll Galv...

Страница 12: ...Inner groove Inner groove Inner groove Rows 2 2 2 2 Fin Type Uncoated Corrugate Fins per inch 16 16 16 16 Refrigerant Flow Control FAN Fan Type Propeller Propeller Propeller Propeller No used 2 2 2 2...

Страница 13: ...nner groove Inner groove Inner groove Inner groove Rows 2 2 2 2 Fin Type Uncoated Corrugate Fins per inch 16 16 16 16 Refrigerant Flow Control FAN Fan Type Propeller Propeller Propeller Propeller No u...

Страница 14: ...14 TTA R410A Refrigerant Circuit TTA B51 B65 JDF Single Circuit TTA 075 150 JDF Single Circuit TTA 150 240 JD00 Dual Circuit TTA 150 240 JD0G Manifolded Comp Figure 4A Figure 4B...

Страница 15: ...PVU VM KPZJVUULJ Z P JOLZ T Z JVTWS P O HSS HWWSPJHISL JVKLZ KPZJVUULJ Z P JO HUK SVJR PU VWLU WVZP PVU V WYL LU HJJPKLU HS WV LY HWWSPJH PVU HPS YL V KV ZV TH YLZ S PU WLYZVUHS PUQ Y VY KLH O K L V...

Страница 16: ...LINE ARE CIRCUIT IDENTIFICATION COMPRESSOR HTR 4 6 5 T1 T2 T3 TTA B51 B65 JDF SINGLE CIRCUIT WIRING DIAGRAM ELEMENTARY DIAGRAM 4 9 13 12 10 11 8 7 5 6 N 7A TERMINAL GROUND HTR 3 2 1 POWER SUPPLY 380V...

Страница 17: ...ON FIELD WIRING OPTION FACTORY WIRING DEVICES BY MFR 1TB TERMINAL BLOCK CONTROL CIRCUIT RELAY TIME DELAY 3 MIN THERMOSTAT RELAY CONTROL LOCKOUT CONTROL LOW PRESS CONTACTOR COMPRESSOR HEATER CRANKCASE...

Страница 18: ...MINAL BLOCK HIGH VOLTAGE 2HTR 8 9 10 T3 1TH 1PB 2PB 3M 1HTR 2HTR 2TR 1TR 1R 2R 1M 2M T1 T2 LEGEND 1LP 2LP FU 1HP 2HP FUSE 5 AMP 20 19 GRAPHIC ELECTRICAL STANDARDS RELAY CONTACTS CIRCUIT IDENTIFICATION...

Страница 19: ...B 2PB 4M CONTACTOR COMPRESSOR RELAY CONTROL LOCKOUT RELAY TIME DELAY 4 5 MIN RELAY TIME DELAY 3 MIN HEATER CRANKCASE SWITCH PUSH BOTTON FUSE 5 AMP CONTROL LOW PRESS CONTROL HIGH PRESS A1 A2 AUXILIARY...

Страница 20: ...INE CONNECTION FEMALE BLAZED DIA 7 8 C LIQUID LINE CONNECTION FEMELE BLAZED DIA 1 2 TTAB65 TTAB51 A ELECTRIC WIRING OUTLET B GAS LINE CONNECTION FEMALE BLAZED DIA 7 8 C LIQUID LINE CONNECTION FEMELE B...

Страница 21: ...TTA R410A 21 Dimensional Data TTA 075 100 120 JDF SINGLE CIRCUIT HORIZONTAL AND VERTICAL DISCHARGE...

Страница 22: ...22 TTA R410A Dimensional Data TTA 150 JDF SINGLE CIRCUIT HORIZONTAL AND VERTICAL DISCHARGE...

Страница 23: ...TTA R410A 23 Dimensional Data TTA 150 180 200 240 JD00 DUAL CIRCUIT...

Страница 24: ...24 TTA R410A Dimensional Data TTA 150 180 200 240 JD0G MANIFOLDED COMPRESSOR...

Страница 25: ...ge pressure exceeds the High Pressure Cut Out s setting Internal Overload Protector IOL This device is a current thermal actuated warp switch imbedded in the compressor motor windings If will shut off...

Страница 26: ...nnually Cooling Season The following maintenance procedures must be performed at the beginning of HDFK FRROLQJ VHDVRQ WR LQVXUH HI FLHQW unit operation Perform all of the monthly maintenance inspectio...

Страница 27: ...ning the unit by avoiding serious and costly breakdown S S S S S S Table 6 Troubleshooting Chart Refrigerant Circuit S S P S P h g i H o o T e r u s s e r P d a e H P S S S P S P P P S P P S P P P P P...

Страница 28: ...nd specifications without notice We are committed to using environmentally conscious print practices Trane by Trane Technologies NYSE TT a global climate innovator creates comfortable energy efficient...

Отзывы: