Electrical Wiring

22

16

20

21

18

15

14

13

12

7

11

10

9

8

6

4
5

3

2

1

ELEMENTARY DIAGRAM

17

19

WIRING DIAGRAM

TTA 150-240 JD0G (Manifolded Compressor)

CONNECTION DIAGRAM

1HTR

INTERNAL OVERLOAD

COMPR. NO.1

T3

5

4 6

~

T2

T1

2HTR

INTERNAL OVERLOAD

COMPR. NO.2

T3

10

8

9

~

T1

T2

34 14E

~ ~

14F

~

35

~

6  MOTORS ARE INHERENTLY PROTECTED.

   A TEMPERATURE RANGE OF 32°F TO 53.5°F.

7  THIS UNIT TO BE USED WITH EVAPORATORS OPERATING WITH IN

1  ALL FIELD WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC

   CODE (N.E.C.) CANADIAN ELECTRIC CODE AND/OR LOCAL STATE AND 
   CITY CODES. PROVIDE DISCONNECTS FOR ALL POWER SUPPLIES.

2  DRAWING PRACTICES AND SYMBOLS ARE IN ACCORDANCE WITH AIR 

CONDITIONING & REFRIGERATION INSTITUTE (ARI) 

3  NUMBERS ALONG LEFT SIDE OF ELEMENTARY DIAGRAM DESIGNATE

   LINE IDENTIFICATION. NUMBERS ALONG RIGHT SIDE ARE LOCATIONS OF 

4  COMPONENT TERMINAL MARKINGS ARE INDICATED BY ENCIRCLED 

5  NUMBERS ON VERTICAL & HORIZONTAL LINE ARE 

GRAPHIC ELECTRICAL STANDARDS.

   RELAY CONTACTS.

CIRCUIT IDENTIFICATION.

   NUMBERS AND/OR LETTERS.

NOTES

8  BUILT IN THERMAL PROTECTOR CAN BE SKIP OVER THEIR CONNECTION.  

CONTACTOR,EVAP.BLOWER MOTOR

          (OPEN : 398 PSIG,CLOSE : 313 PSIG)

          (OPEN : 27 PSIG,CLOSE : 46 PSIG)

          1TB-TERMINAL BLOCK CONTROL CIRCUIT

          2TB-TERMINAL BLOCK HIGH VOLTAGE
          FACTORY WIRING & DEVICES BY MFR.

1TH

THERMOSTAT 2 STAGES.

          FIELD WIRING (OPTION)

FU

LEGEND

1HP,2HP

1R,2R,3R

1M,2M

2TR

1TR

1HTR,2HTR

1LP,2LP

1PB,2PB

4M

CONTACTOR,COMPRESSOR

RELAY,CONTROL LOCKOUT

RELAY,TIME DELAY 4.5 MIN.

RELAY,TIME DELAY 3 MIN.

HEATER,CRANKCASE.

SWITCH PUSH BOTTON

FUSE 5 AMP.

CONTROL,LOW PRESS.

CONTROL,HIGH PRESS.

A1,A2

AUXILIARY CONTACT(N.O.) OF 4M

CONTACTOR,FAN MOTOR

3M

EXTERNAL OVERLOAD, COMPRESSOR 

1OL,2OL

PHASE PROTECTOR

PH

1LP

~

24

1HP

~

1TP

15

2LP

~

25

2HP

~

2TP

18

THERMAL PROTECTOR, MOTOR

1TP,2TP

4M-A2

380

V

./

3

P

H

./

5

0

/6

0H

Z

.

P

O

W

E

R

 S

U

PP

LY

1M-3

NO.1

2HTR

1HTR

23

13

1TH-2

1PB

4M-A1

1TH-1

FU

GROUND

TERMINAL

L3

3

EXTERNAL CONTROL

2

1

16

2

2TR

19

2PB

1

1TR

1M

1M-1,2,3

6

5

1

26

4M

6

5

2R

1

27

7 2R

8

14B

2M

2M-5,6,7

4M-16,22

7 1R

1R

8

FAN

MOTOR

NO.1

A

C

2M-1

2M-3

2M-2

B

COMPR.

NO.2

T3

T2 MOTOR

T1

T3

NEUTRAL

N

L2

L1

1

2

ELEMENTARY DIAGRAM

1M-1

1M-2

COMPR.

T2 MOTOR

T1

3M-2

29

3M-3

30

3M-1

28

B

A

NO.2

C

FAN

MOTOR

3M

7 3R 8

3M-8,9,10

31

3R-2

3R-1

6

3

4

2

3R-17,19

2R-20

1R-16

4

5

6

10

9

8

20

15

1LP

1HP

24

95

96

1OL

1TP

25

18

2LP

2HP

21

95

96

2OL

2TP

PH

BRW

BLK

GY

BRW

BLK

GY

14

14E

14F

14G

14C

14A

14D

N 14A

19

19

380V./3PH./50HZ.

26

6

5

26A

FAN

MOTOR

NO.2

C

B

A

POWER SUPPLY

~

30A

29A

2TB

28A

~

2

1

1A 2A

3

3A

FAN

NO.1

MOTOR

C

B

A

30

29

28

24A

7

26A

8

1R

1R

1

20

3

2

4

31

5

6

1TR

23

   23

16

13
16

14,14G,N

24, 24A

N

2

1TB

1

16

31

2TR

25, 25A

2

1

19

1B

14D

26C

1D

3R

7

8

26C

23

1
3

3R

2
4

27

2R 4

3

7

25A

27A

5

8

2R

27A

6

21

1

2

26A

27A

14

14E,14F

30

29

28

28A 29A 30A

14

L3

T3

96

T2

L2

T1

L1

T1

1OL

95

T2 T3

4

5

6

20

15

1

2

3

14A 26

3C

1M

26A

1C,1D

L3

T3

96

T2

L2

T1

L1

T1

2OL

95

T2 T3

8

9

10 21

18

1A 2A 3A

14B 27

2M

14C 27A

1B 2B 3B

2C

14B

3M

2B

3B

14C

14D

34,35

          OPEN : 460 PSIG,CLOSE : 360 PSIG)

(HI-AMBIENT OPTION 

Содержание ODYSSEY TTA 051 JDF

Страница 1: ...altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are...

Страница 2: ...Design Sequence Fourth Design Sequence New Design 1 Fan New comp change Unit Hi Ambient Temp Fifth Design Sequence Q R S J F No Option Copper Fin Blue Fin Single Circuit Manifolded Compressor for TTA1...

Страница 3: ...recaution General Information Installation Refrigerant Piping Guidelines Refrigerant Charging and Evacuation General Data Refrigerant Circuit Electrical Wiring Dimensional Data Operation Maintenance T...

Страница 4: ...g leakage of water etc Be sure to cut off the main power in case of setting up the indoor electronic control P C board or wiring works It could cause an electri shock Any presence of foreign substance...

Страница 5: ...Cautions appear at appropriate places in this manual Your personal safety and the proper operation of this machine require that you follow them carefully The Company assumes no liability for installa...

Страница 6: ...to insure proper unit operation A Do not install the unit under a low overhang Condenser discharge clearance is not less than 2 5 mm Important Do not obstruct condenser discharge air This can result i...

Страница 7: ...TTA 150 200 Dual Circuit TTA B51 B65 Single Circuit TTA 075 100 Single Circuit Suction line Liquid line 1 1 8 inch sealed type L refrigerant tubing 1 2 inch sealed type L refrigerant tubing D Recommen...

Страница 8: ...d the gauge manifold Figure 2 Unregulated pressures can damage system components protect painted surfaces from excessive heat Heat can damage system components and the unit UPZO 6 Shut off nitrogen su...

Страница 9: ...8 60 6 30 13 89 6 30 13 89 6 10 13 45 5 40 11 90 6 75 14 88 6 75 14 88 13 50 29 76 12 60 27 78 12 20 26 90 10 30 23 81 TTA 100 JDF Tubing Sizes Additional Additional See Suction Liquid Tubing Length...

Страница 10: ...only as required to obtain correct head and suction pressure Check suction line superheat and condenser sub cooling to ensure the unit is operating properly 4 Disconnect all power to the unit 5 Remov...

Страница 11: ...mm 743 x804 x 781 743 x804 x 781 WEIGHT Crated Shipping kg 86 91 Uncrated Net kg 80 85 1 MCA Minimum Circuit Ampacity 2 CFM is rated with standard air dry coil PSC Holding Charge Hermetic Scroll Galv...

Страница 12: ...Inner groove Inner groove Inner groove Rows 2 2 2 2 Fin Type Uncoated Corrugate Fins per inch 16 16 16 16 Refrigerant Flow Control FAN Fan Type Propeller Propeller Propeller Propeller No used 2 2 2 2...

Страница 13: ...nner groove Inner groove Inner groove Inner groove Rows 2 2 2 2 Fin Type Uncoated Corrugate Fins per inch 16 16 16 16 Refrigerant Flow Control FAN Fan Type Propeller Propeller Propeller Propeller No u...

Страница 14: ...14 TTA R410A Refrigerant Circuit TTA B51 B65 JDF Single Circuit TTA 075 150 JDF Single Circuit TTA 150 240 JD00 Dual Circuit TTA 150 240 JD0G Manifolded Comp Figure 4A Figure 4B...

Страница 15: ...PVU VM KPZJVUULJ Z P JOLZ T Z JVTWS P O HSS HWWSPJHISL JVKLZ KPZJVUULJ Z P JO HUK SVJR PU VWLU WVZP PVU V WYL LU HJJPKLU HS WV LY HWWSPJH PVU HPS YL V KV ZV TH YLZ S PU WLYZVUHS PUQ Y VY KLH O K L V...

Страница 16: ...LINE ARE CIRCUIT IDENTIFICATION COMPRESSOR HTR 4 6 5 T1 T2 T3 TTA B51 B65 JDF SINGLE CIRCUIT WIRING DIAGRAM ELEMENTARY DIAGRAM 4 9 13 12 10 11 8 7 5 6 N 7A TERMINAL GROUND HTR 3 2 1 POWER SUPPLY 380V...

Страница 17: ...ON FIELD WIRING OPTION FACTORY WIRING DEVICES BY MFR 1TB TERMINAL BLOCK CONTROL CIRCUIT RELAY TIME DELAY 3 MIN THERMOSTAT RELAY CONTROL LOCKOUT CONTROL LOW PRESS CONTACTOR COMPRESSOR HEATER CRANKCASE...

Страница 18: ...MINAL BLOCK HIGH VOLTAGE 2HTR 8 9 10 T3 1TH 1PB 2PB 3M 1HTR 2HTR 2TR 1TR 1R 2R 1M 2M T1 T2 LEGEND 1LP 2LP FU 1HP 2HP FUSE 5 AMP 20 19 GRAPHIC ELECTRICAL STANDARDS RELAY CONTACTS CIRCUIT IDENTIFICATION...

Страница 19: ...B 2PB 4M CONTACTOR COMPRESSOR RELAY CONTROL LOCKOUT RELAY TIME DELAY 4 5 MIN RELAY TIME DELAY 3 MIN HEATER CRANKCASE SWITCH PUSH BOTTON FUSE 5 AMP CONTROL LOW PRESS CONTROL HIGH PRESS A1 A2 AUXILIARY...

Страница 20: ...INE CONNECTION FEMALE BLAZED DIA 7 8 C LIQUID LINE CONNECTION FEMELE BLAZED DIA 1 2 TTAB65 TTAB51 A ELECTRIC WIRING OUTLET B GAS LINE CONNECTION FEMALE BLAZED DIA 7 8 C LIQUID LINE CONNECTION FEMELE B...

Страница 21: ...TTA R410A 21 Dimensional Data TTA 075 100 120 JDF SINGLE CIRCUIT HORIZONTAL AND VERTICAL DISCHARGE...

Страница 22: ...22 TTA R410A Dimensional Data TTA 150 JDF SINGLE CIRCUIT HORIZONTAL AND VERTICAL DISCHARGE...

Страница 23: ...TTA R410A 23 Dimensional Data TTA 150 180 200 240 JD00 DUAL CIRCUIT...

Страница 24: ...24 TTA R410A Dimensional Data TTA 150 180 200 240 JD0G MANIFOLDED COMPRESSOR...

Страница 25: ...ge pressure exceeds the High Pressure Cut Out s setting Internal Overload Protector IOL This device is a current thermal actuated warp switch imbedded in the compressor motor windings If will shut off...

Страница 26: ...nnually Cooling Season The following maintenance procedures must be performed at the beginning of HDFK FRROLQJ VHDVRQ WR LQVXUH HI FLHQW unit operation Perform all of the monthly maintenance inspectio...

Страница 27: ...ning the unit by avoiding serious and costly breakdown S S S S S S Table 6 Troubleshooting Chart Refrigerant Circuit S S P S P h g i H o o T e r u s s e r P d a e H P S S S P S P P P S P P S P P P P P...

Страница 28: ...nd specifications without notice We are committed to using environmentally conscious print practices Trane by Trane Technologies NYSE TT a global climate innovator creates comfortable energy efficient...

Отзывы: