Installation

Installation diagram

Unit: 

ǖ

mm

Ground

Ceiling

Ground

Ceiling

Wall

>150

>150

>150

>2000

>3000

Only air conditioning unit installed by professionals in accordance with this manual can 

• 

ensure good status.

Hanging plate installation

Find the level position with hanging line. When adjust the board, the left side should be 

• 

lower since the drainage pipe is at the same side. 

Fix the hanging plate on the wall with screws.

• 

Pull the hanging plate to make sure it is fi xed after installation completed. Properly installed 

• 

hanging plate can withstand 60kg and all fi xed screws are stressed uniformly.

Outlet pipe wall hole diameter: 50mm for MW(C)W509/512, and 65mm. for MW(C)W518.

• 

Outlet pipe wall hole Ø

Drill piping hole

 Drill a outward-dipping hole (

˫

50 or 

˫

65) after determining the piping hole position.

• 

 Install wall pipe to prevent piping and cable through the wall from damaging.

• 

Содержание MW(C)W509

Страница 1: ...Indoor Unit Installation Operation Manual Advanced Multi split System Wall mounted Indoor Unit MW C W509 512 518 R410A 200061350200 April 2012 AMS SVX03A EN...

Страница 2: ...n 9 Electrical control wiring 12 Indoor and outdoor unit communication wires specification and attention 12 Electrical parameters 13 Electrical wiring diagram 14 DIP setting 15 Controller instruction...

Страница 3: ...oor and outdoor units User must cut off the main power supply for all units before cleaning User should keep the unit powered on If user do not use the unit for a long term please cut off power supply...

Страница 4: ...ay reduce the unit service life Do not damage the wires or use non specified wires otherwise it may cause electric shock or fire Do not touch air conditioning unit with wet hands which is danger of el...

Страница 5: ...oning unit earth avoiding electric shock The earth wire should not connect with gas pipe water pipe lightning rod or phone line Switch off the unit after 5 minutes running at least otherwise it may re...

Страница 6: ...Nominal cooling capacity 09 12 18 Digit 7 Design serial no M Free split inverter indoor unit system with electronic expansion valve Digit 8 Power supply type M 220 240V 50Hz 1PH Digit 9 Electric heate...

Страница 7: ...Unit outline dimension Model MW C W509 MW C W512 MW C W518 A 843 940 940 B 275 298 298 C 180 200 200 AMS SVX03A EN 7...

Страница 8: ...Unit components and names Note Appearances of air conditionings may differ by models Air inlet Strainer Panel Air guide slide Air outlet Connecting pipe Wiring cover plate 8 AMS SVX03A EN...

Страница 9: ...er since the drainage pipe is at the same side Fix the hanging plate on the wall with screws Pull the hanging plate to make sure it is fixed after installation completed Properly installed hanging pla...

Страница 10: ...sted bulged or waved etc Do not insert the outlet port into water Bulged DO not insert it into water Twisted Connecting pipe installation Connect the connecting pipe and two indoor unit extraction pip...

Страница 11: ...or 1 2 and 3 for leading connecting pipes and wires and are recommended pipe arrangement Packed piping and wire are through the piping hole as shown in fig d Connect the claw at the indoor unit backsi...

Страница 12: ...ion wire before power on Do not plug in and out with electricity avoiding communication chip damage Control signal circuit must use STP avoiding strong electric signal interference Choose network wire...

Страница 13: ...Install the wiring cover plate to original position tighten screws and cover the panel Electrical parameters Model Frequency Hz Rated voltage V Voltage range V Fan motor rated current FLA A Without e...

Страница 14: ...the polarity Port A and B of two indoor units or indoor unit and outdoor unit can not be reversed Connect shield ground wire to port G of DIP board The DIP board can connect multiple communication wir...

Страница 15: ...ches for SW2 at the control board S1 S2 S3 and S4 are capacity DIP switches as followings S1 S2 S3 S4 Indoor unit capacity kW 0 0 0 0 2 8 0 0 0 1 3 6 0 0 1 0 5 0 Indoor unit fan speed gear selection C...

Страница 16: ...oard S1 S2 S3 and S4 are address DIP switches as followings S1 S2 S3 S4 Indoor unit address 0 0 0 0 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 4 0 1 0 0 5 0 1 0 1 6 0 1 1 0 7 0 1 1 1 8 Note 1 Indoor unit address s...

Страница 17: ...le this function Quick Cooling Heating If current mode is Cooling press this key to enter the Quick Cooling mode if current mode is Heating press the key to enter the Quick Heating mode Auto On Off ti...

Страница 18: ...n Heating mode Dry LED it is on when the unit is operating in Dry mode Run LED it is on when the unit is running In initial power on or reset Power LED 1 is on after one second flashing of all LEDs In...

Страница 19: ...ectly for a long time and set too low room temperature which is unhealthful Do not spray water or clean the unit with water which may cause fault or electric shock Do not damage power cords and signal...

Страница 20: ...remove the panel Clean the panel with soft brush water and neutral cleanser followed the drying with water 2 throw off or in a cool place Reinstall the panel 3 As shown in the figure below put the pan...

Страница 21: ...re the beginning of service season Check that both inlet and outlet of the unit are not blocked Check if earth wire is grounded reliably Check if the battery of remote controller has been changed Chec...

Страница 22: ...or low voltage Remote controller auto ON is not set Poor air conditioning cooling heating performance Improper setting temperature Blocked air inlet outlet of the indoor unit Blocked air strainer Doo...

Страница 23: ...mprovement and reserves the right to change design and specifications without notice Literature Order Number Date Supersedes AMS SVX03A EN April 2012 New Trane www trane com For more information conta...

Отзывы: