background image

 

 

 

 

8

HFCF-SVX01A-

EN 

                                                                                                         

Dimension Data and Weights 

 

 

Figure 4: HFCF Without Return Plenum              Figure 5: HFCF With Bottom Plenum 

         

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6: HFCF With Rear Plenum 

 

 

 

 

 

 

     

 

 

 

 

 

 

 

 

 

 

 

 

Without Plenum Net Weight(Kg) 

With Plenum Net Weight(Kg) 

Size mm 

Normal Static  

High Static  

Normal Static  

High Static  

Unit 

Model 

Motor 

Qty  

Fan 
Qty  

Rows 

Rows 

Rows 

Rows 

Rows 

Rows 

Rows 

Rows 

Rows 

Rows 

Rows 

Rows 

HFCF02 

458 

485 

648 

547 

12 

13 

14 

13 

14 

15 

15 

16 

17 

16 

17 

18 

HFCF03 

693 

720 

883 

782 

16 

18 

20 

17 

19 

21 

20 

22 

24 

21 

24 

25 

HFCF04 

793 

820 

983 

882 

17 

19 

21 

18 

20 

22 

21 

23 

25 

22 

25 

26 

HFCF05 

913 

940 

1103 

1002 

19 

21 

23 

20 

22 

24 

24 

26 

28 

24 

28 

28 

HFCF06 

963 

990 

1153 

1052 

20 

22 

24 

21 

23 

25 

25 

27 

29 

25 

29 

29 

HFCF08 

1243 

1270 

1433 

1332 

28 

30 

32 

29 

31 

33 

34 

36 

38 

35 

38 

39 

HFCF10 

1493 

1520 

1683 

1582 

30 

33 

36 

32 

35 

38 

37 

40 

43 

39 

43 

45 

HFCF12 

1663 

1690 

1853 

1752 

35 

38 

41 

36 

39 

42 

43 

46 

49 

44 

49 

50 

HFCF14 

1793 

1820 

1983 

1882 

37 

40 

43 

38 

41 

44 

45 

48 

51 

46 

51 

52 

                                                                                                   

 6

111

10

145

24

270

14

211

12

43

 A

 B

 C

 29

 

11

 

18

 14

View A

543

520

248

248

198

 D

        Outlet  water Collar

3/4-inch female pipe t hread(FPT)

        Inlet water Collar
3/4-inch  female pipe thread(FPT)

Header of  drain water

         (3/4 MPT)

Hanger Holes(Qty.6) See View A

Coil

Return  Plenum

Control Box

Drain Pan

 216

 230

Bottom return
intake

Outlet

Outlet

Motor

Centrif ugal Fan

188

147

Unit: mm

 6

487

464

192

111

10

145

24

270

14

211

12

 A

 B

 C

 29

 

11

 

18

 14

View  A

       Outlet water Collar

3/4-inch female pipe thread(FPT)

       Inlet w ater Collar
3/4-inch female pipe thread(FPT)

Header of drain water
        (3/4 MPT)

43

C oil

Centrifugal

      Fan

Motor

Hanger Holes(Qty.4) See View A

Control Box

216

 230

Drain Pan

Outlet

147

Outlet

Unit: mm

 6

522

499

111

10

145

24

270

14

211

12

43

 A

 B

 C

29

 

11

 

18

 14

View A

243

198

226

 D

Hanger Holes(Qty.6) See View A

Header of drain water
        (3/4 MPT)

       Outlet water Collar
3/4-inch female pipe thread(FPT)

         Inlet water Collar
3/4-inch female pipe thread(FPT)

Coil

 216

 230

Outlet

Rear return
intake

Outlet

Drain Pan

Centrifugal Fan

Motor

Return Plenum

Filters

188

147

Control Box

Unit: mm

Содержание HFCF-SVX01A-EN

Страница 1: ...Installation Operation Maintenance Chilled Water Fan Coil Unit Airflow 200 1400CFM HFCF SVX01A EN...

Страница 2: ...ections Figure 2 Typical Installation Figure 3 Duct Work Dimension Data and Weights 9 Figure 4 HFCF Without Reture Plenum Figure 5 HFCF With Bottom Return Plenum Figure 6 HFCF With Rear Return Plenum...

Страница 3: ...e motor The motor lead out wires are enclosed by flexible metal conduit and providing protection against damage Coil The coil can have 2 3 or 4 rows with copper tubes mechanically bonded into slit alu...

Страница 4: ...tor Type N Normal H High Static A DCBL Normal w LCD thermostat B DCBL High Static w LCD thermostat C Hermetic Motor Normal Type D Hermetic Motor High Static Type Digit 11 Voltage Hz Phase 1 220 50 1 2...

Страница 5: ...mm Non flammable Close Cell Insulation Extended 310mm N STD Galvanized Steel w 10mm Non flammable Close Cell Insulation P STD Galvanized Steel w 10mm Non flammable Close Cell Insulation Extended 200mm...

Страница 6: ...drainage and operation 5 Ducting connected to units where applicable should not exceed the external static pressure rating of the unit 6 Condensate protection for the chilled water valves and piping m...

Страница 7: ...wiring diagram decals on each unit Also see Figure 7 for wiring diagrams A grounding point which must be properly connected to the building grounding system has been provided with a mark on the verti...

Страница 8: ...Dimension Data and Weights Figure 2 Typical Installation Figure 3 Duct Work 8...

Страница 9: ...3 1820 1983 1882 2 4 37 40 43 38 41 44 45 48 51 46 51 52 6 111 10 145 24 270 14 211 12 43 A B C 29 11 18 14 View A 543 520 248 248 198 D Outlet water Collar 3 4 inch female pipe thread FPT Inlet water...

Страница 10: ...Wiring Diagram Figure 7 Model HFCF Wiring Diagrams 10...

Страница 11: ...prepared for weight leveling and service access Unit is mounted securely to the ceiling support rods Ductwork connections are complete Coil connections are complete and tight Condensate drain pan con...

Страница 12: ...tout 85 auto reset is provided to de energize electric heat in the event of an overheat condition In addition to the automatic reset cutout the unit also equipped with another high temperature cutout...

Страница 13: ...Figure 8 Fan Board Assembly Maintenance...

Страница 14: ...source To clean permanent filters remove the filter media and wash it in water to remove dust dirt and lint allow to dry thoroughly before re installing in the unit Change Entire Fan Board The entire...

Страница 15: ...oling capacity Followings are the cleaning steps 1 Disconnect the power and motor wire and stop the fan 2 Remove the whole fan seat and clean from the air inlet 3 Clean the coil fin using rigid nylon...

Страница 16: ...e office or e mail us at comfort trane com Literature Order Number Date Supersedes HFCF SVX01A EN March 2008 New Trane has a policy of continuous product and product data improvement and reserves the...

Отзывы: