Start Up / Operation

 

 

 

 

 

 

Preparation

 

Before starting the unit, complete the above 
mentioned INSTALLATION CHECKLIST to 
ensure the proper start-up preparation is 
completed. 

 

Operation

 

Fan coil operation can be controlled by a 
simple motor speed switch or a thermostat 
unit. 

 

The wall-mounted thermostat unit usually 
includes a motor speed switch, an on/off 
switch and a thermostat. The on/off switch 
turns the unit on and off and the motor 
speed switch controls the fan speed. The 
thermostat controls the water valve and 
usually has a dial to select an approximate 
setting temperature. 

 

If the associated thermostat is not used for 
control, the installer should choose other 
type of thermostat which complies with the 
safety codes. 

 

The  simple  motor  speed  switch,  labeled  Off- 
Hi-Med-Low, controls the fan coil by turning the 
switch  to  different  speed  for  adjusting  the  air 
flow. 

 

 

 

 

 

 

 

 

 

 

For the unit with electric heater option, a 
high temperature cutout with automatic reset 
(105

  cutout, 85

  auto reset) is provided 

to de-energize electric heat in 
the event of an overheat condition. In addition 
to the automatic reset cutout, the unit also 
equipped with another high temperature 
cutout with manual reset (130

  cutout). 

These two temp. cutouts provide double 
protection for electric heat operation. 

 

Coil Venting

 

When water is first introduced into a coil, air 
is sometimes trapped in the coil tubing. This 
trapped air has a tendency to collect at the 
highest point in the coil. Therefore, a manual 
air vent is installed at the highest point of the 
header. When there appears to be air trapped 
in the coil, resulting in "bubbling" or 
"clanking" noises within the unit, release air 
from the manual air vent by rotating the knob. 
A pair of pliers can be used if the knob is too 
tight to turn by hand. Turn knob counter 
clockwise 1-2 turns and allow air to flow out 
of the air vent until a steady stream of water 
appears. Then retighten knob. 
 

Coil drainage 
When the coil need to maintenance, or 
protected the water frozen in the low 
temperature condition,  you should turn the 
water vent  for drainage the water in the coil. 
The operator manner just like as the air vent.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 

 

 

 

 

 

 

 

 

 

 

 

 

 

HFCF-SVX01A-EN

Содержание HFCF-SVX01A-EN

Страница 1: ...Installation Operation Maintenance Chilled Water Fan Coil Unit Airflow 200 1400CFM HFCF SVX01A EN...

Страница 2: ...ections Figure 2 Typical Installation Figure 3 Duct Work Dimension Data and Weights 9 Figure 4 HFCF Without Reture Plenum Figure 5 HFCF With Bottom Return Plenum Figure 6 HFCF With Rear Return Plenum...

Страница 3: ...e motor The motor lead out wires are enclosed by flexible metal conduit and providing protection against damage Coil The coil can have 2 3 or 4 rows with copper tubes mechanically bonded into slit alu...

Страница 4: ...tor Type N Normal H High Static A DCBL Normal w LCD thermostat B DCBL High Static w LCD thermostat C Hermetic Motor Normal Type D Hermetic Motor High Static Type Digit 11 Voltage Hz Phase 1 220 50 1 2...

Страница 5: ...mm Non flammable Close Cell Insulation Extended 310mm N STD Galvanized Steel w 10mm Non flammable Close Cell Insulation P STD Galvanized Steel w 10mm Non flammable Close Cell Insulation Extended 200mm...

Страница 6: ...drainage and operation 5 Ducting connected to units where applicable should not exceed the external static pressure rating of the unit 6 Condensate protection for the chilled water valves and piping m...

Страница 7: ...wiring diagram decals on each unit Also see Figure 7 for wiring diagrams A grounding point which must be properly connected to the building grounding system has been provided with a mark on the verti...

Страница 8: ...Dimension Data and Weights Figure 2 Typical Installation Figure 3 Duct Work 8...

Страница 9: ...3 1820 1983 1882 2 4 37 40 43 38 41 44 45 48 51 46 51 52 6 111 10 145 24 270 14 211 12 43 A B C 29 11 18 14 View A 543 520 248 248 198 D Outlet water Collar 3 4 inch female pipe thread FPT Inlet water...

Страница 10: ...Wiring Diagram Figure 7 Model HFCF Wiring Diagrams 10...

Страница 11: ...prepared for weight leveling and service access Unit is mounted securely to the ceiling support rods Ductwork connections are complete Coil connections are complete and tight Condensate drain pan con...

Страница 12: ...tout 85 auto reset is provided to de energize electric heat in the event of an overheat condition In addition to the automatic reset cutout the unit also equipped with another high temperature cutout...

Страница 13: ...Figure 8 Fan Board Assembly Maintenance...

Страница 14: ...source To clean permanent filters remove the filter media and wash it in water to remove dust dirt and lint allow to dry thoroughly before re installing in the unit Change Entire Fan Board The entire...

Страница 15: ...oling capacity Followings are the cleaning steps 1 Disconnect the power and motor wire and stop the fan 2 Remove the whole fan seat and clean from the air inlet 3 Clean the coil fin using rigid nylon...

Страница 16: ...e office or e mail us at comfort trane com Literature Order Number Date Supersedes HFCF SVX01A EN March 2008 New Trane has a policy of continuous product and product data improvement and reserves the...

Отзывы: