background image

3

1

2

Installation Instructions

Ducted Filter Rack

Water Source Heat Pumps

Model Number:

GEH/V* & EXH/V*

January 2016

Warnings, Cautions, and Notices

Read this manual thoroughly before operating or servicing this unit.
Safety advisories appear throughout this manual as required. Your
personal safety and the proper operation of this machine depend upon
the strict observance of these precautions.

Important Environmental Concerns

Scientific research has shown that certain man-made chemicals can
affect the earth’s naturally occurring stratospheric ozone layer when
released to the atmosphere. In particular, several of the identified
chemicals that may affect the ozone layer are refrigerants that contain
Chlorine, Fluorine and Carbon (CFCs) and those containing Hydrogen,
Chlorine, Fluorine and Carbon (HCFCs). Not all refrigerants containing
these compounds have the same potential impact to the environment.

Trane advocates the responsible handling of all refrigerants-including

industry replacements for CFCs such as HCFCs and HFCs.

Important Responsible Refrigerant Practices

Trane believes that responsible refrigerant practices are important to the

environment, our customers, and the air conditioning industry. All
technicians who handle refrigerants must be certified.The Federal Clean

Air Act (Section 608) sets forth the requirements for handling,

reclaiming, recovering and recycling of certain refrigerants and the
equipment that is used in these service procedures. In addition, some
states or municipalities may have additional requirements that must
also be adhered to for responsible management of refrigerants. Know
the applicable laws and follow them.

The three types of advisories are defined as follows:

WARNING

Indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury.

CAUTION

Indicates a potentially hazardous situation
which, if not avoided, could result in minor or
moderate injury. It could also be used to alert

NOTICE

Indicates a situation that could result in
equipment or property-damage only accidents.

WARNING

Proper Field Wiring and Grounding Required!

Failure to follow code could result in death or serious injury. All field wiring
MUST be performed by qualified personnel. Improperly installed and grounded
field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards,
you MUST follow requirements for field wiring installation and grounding as
described in NEC and your local/state electrical codes.

WARNING

Personal Protective Equipment Required!

Installing/servicing this unit could result in exposure to electrical, mechanical
and chemical hazards. Before installing/servicing this unit, technicians MUST
put on all Personal Protective Equipment (PPE) recommended for the work
being undertaken. ALWAYS refer to appropriate MSDS sheets and OSHA
guidelines for proper PPE. When working with or around hazardous chemicals,

ALWAYS refer to the appropriate MSDS sheets and OSHA guidelines for

information on allowable personal exposure levels, proper respiratory
protection and handling recommendations. If there is a risk of arc or flash,
technicians MUST put on all necessary Personal Protective Equipment (PPE) in
accordance with NFPA70E for arc/flash protection PRIOR to servicing the unit.
Failure to follow recommendations could result in death or serious injury.

Installation

Horizontal units (filter rack can have top, bottom or side
accessibility)

Figure 1.

Right return, back supply ducted filter rack

Note:

Filter rack shown is accessible from top of the unit.

1. Rotate the filter rack as needed to the required application (right or left

hand return, right or left or top or bottom access) as shown in

Figure 1

.

2. Filter racks are to be installed on the side of the unit. Slide top flange

over the top of cabinet and bottom flange below the bottom of the
cabinet.

3. Line the top/bottom holes with the filter rack top and bottom slots;

refer to

Figure 1

.

4. Attach filter rack to cabinet using # 10-16 x 3/8” screws.These screws

are provided with the unit.

5. Slide the filter provided with the unit into the filter rack (through the

guide rails).

Note:

GEH 006-060 and EXH 018-070 units ship with a filter.This same

filter can be utilized in the ducted filter rack.

WSHP-SVN09B-EN

© 2016 Trane All Rights Reserved

Отзывы: