background image

TRANE

®

8

Unit Installation

Maintenance Contract

It is strongly recommended that you
sign a maintenance contract with your
local Service Agency.  This contract
provides regular maintenance of your
installation by a specialist in our
equipment.  Regular maintenance
ensures that any malfunction is
detected and corrected in good time and
minimizes the possibility that serious
damage will occur.  Finally, regular
maintenance ensures the maximum
operation life of your equipment.  We
would remind you that failure to respect
these installation and maintenance
instructions may result in immendiate
cancellation of the warranty.

Training

The equipment described in this
manual is the result of many years of
research and continuous
developement.  To assist you in
obtaining the best use of it, and
maintaining it in perfect operating
condition over a long period of time, the
constructor have at your disposal a
refrigeration and air conditioning
service school.  The principal aim of
this is to give operators and
maintenance technicians a better
knowledge of the equipment they are
using, or that is under their charge.
Emphasis is particualrly given to the
importance of periodic checks on the
unit operating parameters as well as
on preventive maintenance, which
reduces the cost of owning the unit by
avoiding serious and costly breakdown.

Содержание FWDP 008

Страница 1: ...TRANE R Installation Operation Maintenance Commercial Chilled Water Blower Coil Unit FWDP Models FWDP 008 FWDP 024 FWDP 014 FWDP 028 FWDP 018 FWDP 032 FWDP SVX01A E4 June 08 ...

Страница 2: ...TRANE ...

Страница 3: ...egistered mail Notify the local Trane Sales Office Concealed damage must be reported within 15 days of delivery Check the unit nameplate to confirm that the proper unit was shipped Available power supply must be compatible with electrical characteristics specified on component nameplates Installation General Information This manual covers the installation operation and maintenance of the Trane FWD...

Страница 4: ...TRANE ii Content General Information Model Nomenclature General Data Dimensional Data Unit Installation Wiring Diagrams Unit Installation i 1 2 3 4 6 7 8 ...

Страница 5: ...TRANE 1 FWDP MODEL NOMENCLATURE ...

Страница 6: ...ominal Net weight unit m m m2 m m m m pc pc KW Amps pc kg FWDP008 9 5 0 26 1 1 speed 1 0 165 1 3 1 16 x25 54 FWDP014 9 5 0 26 1 1 0 55 5 6 5 3 4 5 1 16 x25 58 FWDP018 9 5 0 33 1 1 0 55 5 6 5 3 4 5 1 1 15 x20 15 x15 68 FWDP024 9 5 0 46 2 1 0 75 5 8 5 5 4 4 1 1 16 x20 16 x25 82 FWDP028 9 5 0 62 2 1 1 1 9 8 5 7 5 3 16 x20 114 FWDP032 9 5 0 67 2 1 1 1 9 8 5 7 5 2 1 16 x20 16 x25 120 FC Centrifugal Dir...

Страница 7: ...s Note Dimensions are in mm NOTES KDD FAN FOR FWDP 008 014 018 KD2 FAN FOR FWDP 024 028 032 MODEL 008 014 018 024 028 032 A 635 813 1148 1524 1651 B 669 5 847 5 1182 5 1558 5 1685 5 C 703 5 881 5 1216 5 1592 5 1719 5 MODEL 008 014 018 024 028 032 3 ROWS 161 D 4 ROWS 183 6 ROWS 227 ...

Страница 8: ...AINTENANCE The unit can be moved using a forklift of suitable capacity For lifting the unit into an elevated mounting pasition run lifting straps or slings under the unit and attach securely to the lifting device Use spreader bars to protect the unit casing from damage Test lift the unit to determine proper balance and stability Caution Use spreader bars to prevent straps from damaging the unit In...

Страница 9: ...sting structural beams c Coil Piping Connections Coils are fitted with 1 1 4 32mm BSPT MALE threaded connections To complete piping connections attach the water piping with 1 1 4 inch connection to the coil The water inlet is on the bottom and water outlet on the top of the coil Coil connection size and coil connection locations are given in page 3 d Condensate Drain Connections These air handlers...

Страница 10: ...ion transmission may cause a noice problem within the building structure 3 Ensure all connections are tight and no wires exposed 4 All accessories must be installed and wired according to the instructions packaged with that accessory Installation Checklist Complete this checklist once the unit is installed to verify that all recommended procedures have been accomplished before the system is starte...

Страница 11: ...TRANE 7 Wiring Diagram ...

Страница 12: ...s may result in immendiate cancellation of the warranty Training The equipment described in this manual is the result of many years of research and continuous developement To assist you in obtaining the best use of it and maintaining it in perfect operating condition over a long period of time the constructor have at your disposal a refrigeration and air conditioning service school The principal a...

Страница 13: ...this event please refer to your nearest TRANE office For additional information contact FWDP SVX01A E4 June 2008 FWDP SVX01A E4 July 2006 Malaysia Literature Order Number File Number Supersedes Stocking Location Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice Only qualified technicians should perform th...

Отзывы: