background image

© 2010 Trane All rights reserved

 ACC-SVN44D-EN

Warnings, Cautions and Notices

Warnings, Cautions and Notices.

Note that warnings, cautions and notices appear at 

appropriate intervals throughout this manual. Warnings are provided to alert installing contractors 
to potential hazards that could result in personal injury or death. Cautions are designed to alert 
personnel to hazardous situations that could result in personal injury, while notices indicate a 
situation that could result in equipment or property-damage-only accidents.
Your personal safety and the proper operation of this machine depend upon the strict observance 
of these precautions.

Important
Environmental Concerns!

Scientific research has shown that certain man-made chemicals can affect the earth's naturally 
occurring stratospheric ozone layer when released to the atmosphere. In particular, several of the 
identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine, Fluorine 
and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine and Carbon (HCFCs). Not all 
refrigerants containing these compounds have the same potential impact to the environment. 
Trane advocates the responsible handling of all refrigerants-including industry replacements for 
CFCs such as HCFCs and HFCs.

Responsible Refrigerant Practices!

Trane believes that responsible refrigerant practices are important to the environment, our 
customers, and the air conditioning industry. All technicians who handle refrigerants must be 
certified. The Federal Clean Air Act (Section 608) sets forth the requirements for handling, 
reclaiming, recovering and recycling of certain refrigerants and the equipment that is used in these 
service procedures. In addition, some states or municipalities may have additional requirements 
that must also be adhered to for responsible management of refrigerants. Know the applicable 
laws and follow them.

WARNING 

Personal Protective Equipment (PPE) Required!

Installing/servicing this unit could result in exposure to electrical, mechanical and chemical 
hazards. 

Before installing/servicing this unit, technicians MUST put on all Personal Protective 
Equipment (PPE) recommended for the work being undertaken. ALWAYS refer to appropriate 
MSDS sheets and OSHA guidelines for proper PPE. 

When working with or around hazardous chemicals, ALWAYS refer to the appropriate MSDS 
sheets and OSHA guidelines for information on allowable personal exposure levels, proper 
respiratory protection and handling recommendations. 

If there is a risk of arc or flash, technicians MUST put on all necessary Personal Protective 
Equipment (PPE) in accordance with NFPA70E for arc/flash protection PRIOR to servicing the 
unit.

Failure to follow recommendations could result in death or serious injury.

ATTENTION:

 

Warnings, Cautions and Notices appear at appropriate sections throughout 

this literature. Read these carefully.

WARNING:

 Indicates a potentially hazardous situation which, if not avoided, could 

result in death or serious injury.

CAUTION:

 Indicates a potentially hazardous situation which, if not avoided, could 

result in minor or moderate injury. It could also be used to alert against unsafe practices.

NOTICE

:

 Indicates a situation that could result in equipment or property-damage-only 

accidents.

Содержание BAYECON085A

Страница 1: ...Number Used With BAYECON085A TSC YSC036E 060E R WSC060EDR THC YHC036E R WSC036E 048E R BAYECON086A THC YHC036E E TSC YSC036E 060E E BAYECON087A THC YHC048E 120E R WSC060E 3 4 W R TSC072E 120E R WSC07...

Страница 2: ...r Act Section 608 sets forth the requirements for handling reclaiming recovering and recycling of certain refrigerants and the equipment that is used in these service procedures In addition some state...

Страница 3: ...Installation 5 Horizontal Installation 5 Optional Sensors ReliaTel Only 6 Blockoff Asssembly 6 Wiring Connections ReliaTel Units 8 Electromechanical Units 8 Factory Installed Economizer Set Up 9 Down...

Страница 4: ...nd WSC072 120E 1 Sensor Thermistor 1 Grommet 1 Tie Wire 1 Barometric Duct Blockoff Plate Installation Field Installed Note This instruction covers installation of BAYECON085A BAYECON086A T YSC036 060E...

Страница 5: ...from bottom of panel for use later Downflow Installation For Downflow Installation assemble end panel to the economizer Refer to Figure 2 Horizontal Installation For Horizontal Installation assemble e...

Страница 6: ...ctions provided in the kits Blockoff Asssembly The return duct blockoff plate s must be installed prior to the installation of the economizer in the unit Refer to Figure 5 for installation in units wi...

Страница 7: ...e bottom of the economizer and secure bottom left 3 screws Remove the filter access panel Position the adapter backing plate inside the filter section The adapter backing plate will slip over the 3 sc...

Страница 8: ...otor Note If Options Module RTOM is not installed then connect plug 3P4 to 3J4 on the Refrigeration Module RTRM in the control box Electromechanical Units Locate unit wiring harness plug PPM2A and plu...

Страница 9: ...the power can not be inadvertently energized Failure to disconnect power before servicing could result in death or serious injury 1 Remove filter access panel 2 Remove bottom blockoff from its shippin...

Страница 10: ...BAYENTH005A and BAYENTH006B install them now Use the instructions provided in the kits 7 Remove supply and return duct covers from the horizontal openings and install over the downflow opening 8 To r...

Страница 11: ...when the blower circuit is de energized Dry Bulb Settings Standard economizer dry bulb changeover is field selectable to 4 outdoor temperatures See the following table for potentiometer settings The...

Страница 12: ...vember 2009 The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice Only qualified technicians should...

Отзывы: