Trane BAYBARO310A Скачать руководство пользователя страница 1

S

SA

AF

FE

ET

TY

Y W

WA

AR

RN

NIIN

NG

G

Only qualified personnel should install and service the equipment. The installation, starting up,
and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and
requires specific knowledge and training. Improperly installed, adjusted or altered equipment
by an unqualified person could result in death or serious injury. When working on the
equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.

May 2021

R

RT

T--S

SV

VN

N0

03

38

8A

A--E

EN

N

Installation Guide

Barometric Relief Hood

Used with Medium Foundation Light
Commercial Rooftops

M

Mo

od

de

ell #

#:: BAYBARO310A

U

Usse

ed

d w

wiitth

h:: EBC 090-150, GBC 090-150

Содержание BAYBARO310A

Страница 1: ...perly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment May 2021 R RT T S SV VN N0 03 38 8A A E EN N Installation Guide Barometric Relief Hood Used with Medium Foundation Light Commercial Rooftops M Mo ...

Страница 2: ...ed chemicals that may affect the ozone layer are refrigerants that contain Chlorine Fluorine and Carbon CFCs and those containing Hydrogen Chlorine Fluorine and Carbon HCFCs Not all refrigerants containing these compounds have the same potential impact to the environment Trane advocates the responsible handling of all refrigerants including industry replacements for CFCs and HCFCs such as saturate...

Страница 3: ...nd on the tags stickers and labels as well as the instructions below Before installing servicing this unit technicians MUST put on all PPE required for the work being undertaken Examples cut resistant gloves sleeves butyl gloves safety glasses hard hat bump cap fall protection electrical PPE and arc flash clothing ALWAYS refer to appropriate Safety Data Sheets SDS and OSHA guidelines for proper PP...

Страница 4: ...l regulations are more stringent than these policies those regulations supersede these policies Non Trane personnel should always follow local regulations Copyright This document and the information in it are the property of Trane and may not be used or reproduced in whole or in part without written permission Trane reserves the right to revise this publication at any time and to make changes to i...

Страница 5: ...rial Verify that the nameplate data matches the sales order and bill of lading Verify that the unit is properly equipped and there are no material shortages Verify that the power supply complies with the unit nameplate specifications Inspection for Concealed Damage Visually inspect the components for concealed damage as soon as possible after delivery and before it is stored If concealed damage is...

Страница 6: ...General Information The barometric relief hood is sized to provide up to 100 relief It is designed to meet low leak requirements to prevent infiltration of air when closed P Pr re e I In ns st ta al ll la at ti io on n ...

Страница 7: ...n Figure 1 3 Install the provided gasketing on the relief hood mounting flanges 4 Fasten the barometric relief hood over the created opening using the provided self tapping screws see Figure 1 5 Close the unit disconnect switch Figure 1 BAYBAR0310 installation view 27 750 28 500 FIELD SUPPLED AND INSTALLED DUCT WORK CUT IN DUCT NO LARGER THAN 27 75 WIDE x 28 5 TALL DUCT MOUNT RELIEF HOOD BAYBARO31...

Страница 8: ...nformation please visit trane com or americanstandardair com Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice We are committed to using environmentally conscious print practices RT SVN038A EN 28 May 2021 Supersedes New 2021 ...