Chiller Description
Chiller Scope
This manual provides relevant data to properly
operate, maintain, and troubleshoot the Trane
Manhattan™ Gen IIAir-Cooled Modular Chiller.
Operator and maintenance personnel must be a
qualified refrigeration technician and have a working
knowledge of high voltage systems, low voltage
control circuits, and components and functions.
Chiller Capacities
The Manhattan™ Gen II Chiller model is available in 10-
, 12.5- 15-, 20-, 25-, 30-, 40-, 50-, 60-, and 80-ton capacity
modules. Up to 10 modules may connect together in a
standard primary/secondary control system. The
system consists of a primary chiller module that
contains the primary microprocessor controller, the
power distribution panel, one or more secondary
modules, an optional tank and pump module with a
glycol feed system, and expansion tank or sealed
buffer tank, an optional free-cooling module (air cooled
modules). It is important to connect modules in the
correct sequence as detailed in Handling of the
Modules section of the Installation Mechanical chapter.
The Manhattan™ Gen II Chiller uses independent
refrigeration circuits in each module using scroll
compressors. Models are available with either brazed-
plate or shell-and-tube evaporators. The brazed-plate
evaporator is typically made of SAE Grade 316
stainless steel and 99.9% copper brazing materials.
Standard interconnecting headers are composed of
carbon steel.
Water quality must be monitored and maintained by a
water treatment professional familiar with the
materials of construction and operation of the
equipment. The chiller modules arrive fully charged
with refrigerant. As required under Federal regulations,
installation, initial start-up, and technical servicing
should only be performed by fully qualified personnel.
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
Component Description
Every chiller is comprised of four basic components:
compressor, condenser, expansion valve, and
evaporator. Each Manhattan™ Gen II Chiller module
contains one or more of these primary refrigeration
components.
Copeland Compressor
For chillers larger than ten tons, the Copeland scroll compressor with
CoreSense technology is a state-of-the-art compressor with relay and
overload monitoring capabilities designed to accommodate liquids
(both oil and refrigerant) without causing compressor damage. The
Copeland compressor uses CoreSense technology as a sensor to
unlock advanced capabilities such as protection, diagnostics,
communication, and verification. Technicians can make faster, more
accurate decisions resulting in improved compressor performance and
reliability.