88-A4AC6001-1F-EN
21
Indoor Wet Bulb Temp (F)
Outdoor
Dry
Bulb
Temp.
(F)
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
55
7
9
10
11
12
14
15
17
18
20
21
23
24
26
27
29
30
60
5
7
8
9
10
12
13
15
16
18
19
21
22
24
25
27
28
30
31
65
4
6
8
10
11
13
14
16
17
18
19
21
22
24
25
27
28
27
31
70
5
7
8
10
11
13
14
16
17
18
19
21
22
24
25
27
28
30
31
75
5
6
7
9
10
12
14
16
18
19
21
22
24
26
28
29
31
32
80
4
6
7
9
10
11
12
14
16
18
19
21
23
25
26
28
29
31
33
85
4
6
7
9
10
13
14
16
18
20
21
23
24
26
28
29
30
31
32
90
4
6
8
10
11
13
14
16
18
20
22
24
25
27
28
30
31
95
4
6
8
10
13
14
16
18
20
22
23
25
26
28
29
100
6
8
10
12
13
16
18
20
21
23
25
27
29
105
4
6
7
9
11
13
15
18
20
22
24
26
28
110
4
7
9
11
13
16
18
21
23
26
28
115
6
9
12
14
16
19
21
24
26
Using a digital psychrometer, measure the return air wet-bulb temperature at the unit just before the coil. Also measure the outdoor dry-bulb tem-
perature. Use these temperatures to locate the target superheat on the charging table. Do not attempt to charge the system if these conditions fall
outside of this charging table.
ADD refrigerant to DECREASE total superheat. REMOVE refrigerant to INCREASE total superheat. Always allow 10 to 15 minutes of operature
after any refrigerant or air flow change prior to determining the final superheat.
Fixed Orifice Superheat Charging Table
Содержание A4AC6018A1000A
Страница 24: ...24 88 A4AC6001 1F EN 3 1 2 4 Ton Units PRINTED FROM D158514P01 2 1 2 Ton Units Accumulator...
Страница 25: ...88 A4AC6001 1F EN 25 5 Ton Units PRINTED FROM D158515P01...
Страница 26: ...26 88 A4AC6001 1F EN Section 17 Wiring Diagrams 036B 060B Models 018A 048A Models...
Страница 27: ...88 A4AC6001 1F EN 27 036B 060B Models 018A 048A Models...
Страница 28: ...28 88 A4AC6001 1F EN 060A Models...
Страница 29: ...88 A4AC6001 1F EN 29 060A Models...