12
18-AC98D1-7D-EN
With Variable Speed S-Series Furnace
NOTES:
1) For PWM (BK) enabled thermostats, cut the BK jumper on
the IFC and connect wiring.
2) The factory Y1-O jumper must remain in place for proper
LED read out in cooling mode.
3) Y1 and Y2 wiring from the thermostat must connect to
the IFC for proper airflow and LED readout.
4) Single compressor and two compressor airflow is auto-
matically set with the IFC Menu options in ODU section.
2-1=2 stage / 1 compressor (1st stage airflow = 75%)
2-2=2 stage / 2 compressors (1st stage airflow = 50%)
Furnace
Y1
Y1
Thermostat
Outdoor
Unit
R
G
W1
W2
R
G
B/C
B/C
B
Y1
W1
W2
Y2
Y2
Y2
24 VAC HOT
FAN
SOV
24 VAC
Common
HEATING
O
O
BK
BK
(1)
(2)
COOL
1st STAGE
COOL
2nd STAGE
With TEM 3, 4, 6, 8
With TAM 4, 7, 9
• Units with pigtails require wirenuts for connections. Cap all unused wires.
• In AC systems for multiple stages of electric heat, jumper W1 and W2 together if comfort control has only one stage of heat.
• TEM3/4 - Bypass air handler and connect Y from comfort control directly to OD unit
* TEM6 Only
** TEM6 only - When using a BK enabled comfort control, cut BK jumper and bypass Y1 and Y2 at the air handler. Connect BK from comfort
control to BK of the air handler
• TAM4 only - Wire as shown, no BK is available
• TAM7 only - When using a BK enabled comfort control, cut BK jumper on the AFC and connect BK from comfort control to BK of the air handler
Thermostat
Air Handler
Outdoor
Unit
R
G
B
W1
W2
B
Y
R
G
B/C
Y
W1
W2
Blue
24 VAC HOT
FAN
24 VAC
Common
SOV
COOL/HEAT
1st STAGE
HEATING
2nd STAGE
EMERGENCY
HEAT
Pink
White
O
Y1
Y2
*
BK
WH/BLK
BK
WH/BLK
Thermostat
Air Handler
Outdoor
Unit
R
G
B
W1
W2
B
R
G
B/C
Y
l
W1
W2
Blue
24 VAC HOT
FAN
24 VAC
Common
SOV
COOL/HEAT
1st STAGE
HEATING
2nd STAGE
EMERGENCY
HEAT
Pink
White
O
Y
l
Y
O
Y
O
BK
WH/BLK
BK
WH/BLK
**
For 018J - 060J, 060K, and 061C Models:
Содержание 4TTR6018J
Страница 21: ...18 AC98D1 7D EN 21 6030 6036 6041 Models PRINTED FROM D158514P01 6042 6048 Models Printed from D157878...
Страница 23: ...18 AC98D1 7D EN 23 Section 17 Wiring Diagrams 024N 036N Models...
Страница 24: ...24 18 AC98D1 7D EN 024N 036N Models...
Страница 25: ...18 AC98D1 7D EN 25 048N Models...
Страница 26: ...26 18 AC98D1 7D EN 048N Models...
Страница 27: ...18 AC98D1 7D EN 27 060N Models...
Страница 28: ...28 18 AC98D1 7D EN 060N Models...
Страница 29: ...18 AC98D1 7D EN 29 018J 030J 036J 048J Models...
Страница 30: ...30 18 AC98D1 7D EN 018J 030J 036J 048J Models...
Страница 31: ...18 AC98D1 7D EN 31 035J Models PRINTED FROM D157362P05 REVB...
Страница 32: ...32 18 AC98D1 7D EN PRINTED FROM D157362P05 REVB 035J Models...
Страница 33: ...18 AC98D1 7D EN 33 049J 061C Models...
Страница 34: ...34 18 AC98D1 7D EN 049J 061C Models...
Страница 35: ...18 AC98D1 7D EN 35 060J 060K Models...
Страница 36: ...36 18 AC98D1 7D EN 060J 060K Models...
Страница 43: ...18 AC98D1 7D EN 43 Notes...