Installer’s Guide

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — 

This Document is 

customer property

 and is to remain with this unit. Please return to service information pack 

upon completion of work.

2.  INDOOR UNIT AIRFLOW 

Indoor unit must provide the required airflow for the heat 
pump or cooling combinations approved for this coil.

IMPORTANT: Review your installation requirements. Check 

the table on the outline drawing and note all dimensions for 

your coil before beginning the installation.

Table of Contents

General .................................................................................1

Application Information ......................................................1

Recommendation ................................................................2

Furnace in Upflow Position

 ................................................2

Furnace in Downflow Position

 ...........................................2

Installing / Brazing Refrigerant Lines ................................3

Leak Check...........................................................................3

Condensate Drain Piping ....................................................4

Cleaning the Coil .................................................................4

Outline Drawing ...................................................................5

Troubleshooting Indoor TXV / Cooling Mode ...................6

Figure 1

18-AD43D1-1A-EN

Cased Aluminum Coil "Dedicated Upflow"  

Convertible to horizontal with separately purchased kit

Upflow model:

4PXCBU36BS3HAC

NOTE: 

OPTIONAL DOWNFLOW GASKET INSTALLATION: For 

unusually humid applications that expect prolonged 

operation above 70% RH, it is recommended to use the 

BAYGSKT001A0 gasket kit to prevent water from forming 

on the bottom of the drain pan and dripping into the 

supply ductwork.

NOTE: 4PXC upflow coils may be installed in Upflow, Down

-

flow, Horizontal Right with kit, and Horizontal Left with kit.

1.  FURNACE AND COIL 

The coil MUST BE installed downstream (in the outlet air) 
of the furnace.  

WARNING

!

This product can expose you to chemicals including 

lead, which are known to the State of California to case 

cancer and birth defects or other reproductive harm. 

For more information go to www. P65Warnings.ca.gov

A.  GENERAL

This coil is designed for use in combination with a heat pump or 
cooling outdoor section using 

R-410A REFRIGERANT

The 4PXC equipment has been evaluated in accordance with 
the Code of Federal Regulations, Chapter XX, Part 3280 or the 
equivalent. “Suitable for Mobile Home use” The height of the 
Furnace, Coil and discharge duct work must be 7 ft. or less.

Inspect the coil for shipping damage. Notify the transportation 
company immediately if the coil is damaged.

B.  APPLICATION INFORMATION

WARNING (Medium/high pressure) 

Contains Refrigerant!
System contains oil and refrigerant under high pressure. 

Recover refrigerant to relieve pressure before opening the 

system. See unit nameplate for refrigerant type. Do not 

use non-approved refrigerants, refrigerant substitutes, or 

refrigerant additives.
Failure to follow proper procedures or the use of non-

approved refrigerants, substitutes, or refrigerant additives 

could result in death, serious injury, or equipment damage.

WARNING

!

Содержание 4PXCBU36BS3HAC

Страница 1: ...pping into the supply ductwork NOTE 4PXC upflow coils may be installed in Upflow Down flow Horizontal Right with kit and Horizontal Left with kit 1 FURNACE AND COIL The coil MUST BE installed downstre...

Страница 2: ...lling the coil in the horizontal position you MUST use the horizontal kit listed below for this coil model num ber and follow the instructions in the installation guide provided with the conversion ki...

Страница 3: ...TION NOTE TXV bulb MUST be protected wrapped with wet rag or removed while brazing the tubing Overheating of the sensing bulb will affect the functional characteristics and performance of the comfort...

Страница 4: ...g careful to prevent fin damage Use chemical cleaners only when necessary H CONDENSATE DRAIN PIPING Condensate drain connections are located in the drain pan at the bottom of the coil enclosure assemb...