Indoor Unit Installation

WARNING

Hazardous Service Procedures! 

The maintenance and troubleshooting procedures recommended in this section of the 
manual could result in exposure to electrical, mechanical or other potential safety 
hazards. Always refer to the safety warnings provided throughout this manual 
concerning these procedures. When possible, disconnect all electrical power including 
remote disconnect and discharge all energy storing devices such as capacitors before 
servicing. Follow proper lockout/tagout procedures to ensure the power can not be 
inadvertently energized. When necessary to work with live electrical components, have 
a qualified licensed electrician or other individual who has been trained in handling live 
electrical components perform these tasks. Failure to follow all of the recommended 
safety warnings provided, could result in death or serious injury. 

Mounting Location

1.

Always mount the rear panel horizontally.

2.

Fix the rear panel on the selected location

3.

Be sure that the rear panel has been fixed firmly enough to withstand the weight of an adult 
of 60kg, furthermore, the weight should be evenly shared by each screw.

Drilling a hole in the wall to install the piping

The piping can be connected in six different locations on the unit, as shown on figure below:

1.

Drill a 65mm diameter hole in the wall at a slight downward angle toward the outdoor side in 
such a way that the end of the pipe outside is 5 mm lower than the inside.

Installation

Left downward

Left

Rear Left 

Right Downward

Rear Right

Right

Содержание 4MCW

Страница 1: ...adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labe...

Страница 2: ...ailure to use R 410A approved service equipment could result in standard equipment exploding under R 410A higher pressure which could result in death or serious injury NOTICE Use PVE Oil with R 410A M...

Страница 3: ...e advocates the responsible handling of all refrigerants including industry replacements for CFCs such as HCFCs and HFCs Responsible Refrigerant Practices Trane believes that responsible refrigerant p...

Страница 4: ...ing the water drain pipe 10 Installing the unit 10 Installing the connection pipe 11 Connect indoor and outdoor electric wires 12 Installing Outdoor Unit 12 Wiring 12 Air purging and leakage test 12 O...

Страница 5: ...e Specify any damage of the unit on the delivery note and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery Notify the dealer at the same time The unit s...

Страница 6: ...Wireless remote controller 1 3 Remote controller holder 1 4 Battery 2 AAA 1 5V 5 Tapping screw 10 ST4 2 X 25 For mounting plate 6 Drain hose 1 L 2m 7 Thermal insulation 1 35 X 500 8 Drain kit 1 Heat p...

Страница 7: ...cal Installation Indoor Unit Air In Air out Outdoor Unit Air in Air out 1 Front panel 2 Filter 3 Guide Louver 4 Electric plug 5 Manual Switch 6 Receiving Window 7 Bind Tape 8 Remote Control 9 Connecti...

Страница 8: ...oved Outdoor unit WARNING Adequate Support Wall structure must be adequate to support the weight of the unit Failure to ensure adequate structural support could result in unit falling from its locatio...

Страница 9: ...electrician or other individual who has been trained in handling live electrical components perform these tasks Failure to follow all of the recommended safety warnings provided could result in death...

Страница 10: ...the ground wiring Installing the water drain pipe NOTICE Do not wrench or bend the drain hose and make sure the ends of the drain pipe are not under water Failure to do so could result in leakage 1 To...

Страница 11: ...of the piping flare with the relevant valve 2 Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to the following Note First connect the connection pipe to i...

Страница 12: ...age Disconnect all electric power including remote disconnects before servicing Follow proper lockout tagout procedures to ensure the power can not be inadvertently energized Failure to disconnect pow...

Страница 13: ...et of low pressure valve 9 Use soap water or leak hunting meter to check whether the joints are leaking Outdoor condensation drainage Heat pump type only When the unit is heating the condensing water...

Страница 14: ...it noise Have you done the refrigerant leakage test It may cause insufficient cooling heating capacity Is heat insulation sufficient It may cause condensation and dripping Is water drainage well It ma...

Страница 15: ...TTK3509A1AA 4MCW3512A1AA 4TTK3512A1AA 4MCW3518B1AA 4TTK3518B1AA 4MCW3524B1AA 4TTK3524B1AA Refrigerant Charge lbs 2 2 R 410A 2 3 R 410A 4 84 R 410A 5 07 R 410A Length m 8 8 8 8 Gas additional charge g...

Страница 16: ...uding remote disconnects before servicing Follow proper lockout tagout procedures to ensure the power can not be inadvertently energized Failure to disconnect power before servicing could result in de...

Страница 17: ...1234 TTT000 EN 17 Outdoor Units Figure 2 4MCW3518 4MCW3524 Figure 3 4TTK3509...

Страница 18: ...18 1234 TTT000 EN Figure 4 4TTK3512 Figure 5 4TTK3518...

Страница 19: ...1234 TTT000 EN 19 Figure 6 4TTK3524...

Страница 20: ...s Trane offers a broad portfolio of advanced controls and HVAC systems comprehensive building services and parts For more information visit www Trane com Trane has a policy of continuous product and p...

Отзывы: