background image

10

1234-TTT000-EN

 

2.

Insert a sleeve into the hole to prevent the connection piping and wiring from being damaged 
when passing through the hole.

NOTICE

When a wall sleeve is not used, it is then necessary to drill a straight hole in the wall. If 
the hole is not straight and uniform, this could result in water leaking from 
condensation, resulting in property damage.

NOTICE

If a wall sleeve is not mounted in the wall, the wiring between the indoor unit and the 
outdoor unit can possibly be damaged resulting in electrical current loss in the ground 
wiring.

Installing the water drain pipe

NOTICE

Do not wrench or bend the drain hose and make sure the ends of the drain pipe are not 
under water. Failure to do so could result in leakage.

1.

To ensure proper water drainage, the drain hose should be placed at a downward slant.

2.

The water drain pipe must be insulated throughout the house.

Installing the unit

Note:

The piping can be lead out from right, right rear, left, left rear.

1.

When routing the piping and wiring from the left or right side of indoor unit, cut off the 
tailings from the chassis in necessary.

(1).Cut off the tailings 1 when routing the wiring only;

(2).Cut off the tailings 1 and tailings 2 when routing both the wiring and piping.(or 1,2,3)

Under water

Bent

Wrenched

Содержание 4MCW

Страница 1: ...adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labe...

Страница 2: ...ailure to use R 410A approved service equipment could result in standard equipment exploding under R 410A higher pressure which could result in death or serious injury NOTICE Use PVE Oil with R 410A M...

Страница 3: ...e advocates the responsible handling of all refrigerants including industry replacements for CFCs such as HCFCs and HFCs Responsible Refrigerant Practices Trane believes that responsible refrigerant p...

Страница 4: ...ing the water drain pipe 10 Installing the unit 10 Installing the connection pipe 11 Connect indoor and outdoor electric wires 12 Installing Outdoor Unit 12 Wiring 12 Air purging and leakage test 12 O...

Страница 5: ...e Specify any damage of the unit on the delivery note and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery Notify the dealer at the same time The unit s...

Страница 6: ...Wireless remote controller 1 3 Remote controller holder 1 4 Battery 2 AAA 1 5V 5 Tapping screw 10 ST4 2 X 25 For mounting plate 6 Drain hose 1 L 2m 7 Thermal insulation 1 35 X 500 8 Drain kit 1 Heat p...

Страница 7: ...cal Installation Indoor Unit Air In Air out Outdoor Unit Air in Air out 1 Front panel 2 Filter 3 Guide Louver 4 Electric plug 5 Manual Switch 6 Receiving Window 7 Bind Tape 8 Remote Control 9 Connecti...

Страница 8: ...oved Outdoor unit WARNING Adequate Support Wall structure must be adequate to support the weight of the unit Failure to ensure adequate structural support could result in unit falling from its locatio...

Страница 9: ...electrician or other individual who has been trained in handling live electrical components perform these tasks Failure to follow all of the recommended safety warnings provided could result in death...

Страница 10: ...the ground wiring Installing the water drain pipe NOTICE Do not wrench or bend the drain hose and make sure the ends of the drain pipe are not under water Failure to do so could result in leakage 1 To...

Страница 11: ...of the piping flare with the relevant valve 2 Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to the following Note First connect the connection pipe to i...

Страница 12: ...age Disconnect all electric power including remote disconnects before servicing Follow proper lockout tagout procedures to ensure the power can not be inadvertently energized Failure to disconnect pow...

Страница 13: ...et of low pressure valve 9 Use soap water or leak hunting meter to check whether the joints are leaking Outdoor condensation drainage Heat pump type only When the unit is heating the condensing water...

Страница 14: ...it noise Have you done the refrigerant leakage test It may cause insufficient cooling heating capacity Is heat insulation sufficient It may cause condensation and dripping Is water drainage well It ma...

Страница 15: ...TTK3509A1AA 4MCW3512A1AA 4TTK3512A1AA 4MCW3518B1AA 4TTK3518B1AA 4MCW3524B1AA 4TTK3524B1AA Refrigerant Charge lbs 2 2 R 410A 2 3 R 410A 4 84 R 410A 5 07 R 410A Length m 8 8 8 8 Gas additional charge g...

Страница 16: ...uding remote disconnects before servicing Follow proper lockout tagout procedures to ensure the power can not be inadvertently energized Failure to disconnect power before servicing could result in de...

Страница 17: ...1234 TTT000 EN 17 Outdoor Units Figure 2 4MCW3518 4MCW3524 Figure 3 4TTK3509...

Страница 18: ...18 1234 TTT000 EN Figure 4 4TTK3512 Figure 5 4TTK3518...

Страница 19: ...1234 TTT000 EN 19 Figure 6 4TTK3524...

Страница 20: ...s Trane offers a broad portfolio of advanced controls and HVAC systems comprehensive building services and parts For more information visit www Trane com Trane has a policy of continuous product and p...

Отзывы: