WARNING
Hazardous Service Procedures!
The maintenance and troubleshooting procedures recommended in this section of the
manual could result in exposure to electrical, mechanical or other potential safety
hazards. Always refer to the safety warnings provided throughout this manual
concerning these procedures. When possible, disconnect all electrical power including
remote disconnect and discharge all energy storing devices such as capacitors before
servicing. Follow proper lockout/tagout procedures to ensure the power can not be
inadvertently energized. When necessary to work with live electrical components, have
a qualified licensed electrician or other individual who has been trained in handling live
electrical components perform these tasks. Failure to follow all of the recommended
safety warnings provided, could result in death or serious injury.
Troubleshooting
Problems
Possible causes
Air conditioner does not run upon immediately restart after a stop.
To protect the air conditioner upon immediate restart after a stop, the
microcomputer controller will delay the unit for 3 minutes before the
air conditioner will run.
Air conditioner blows out bad smell when it is initially started.
* The air conditioner itself has no bad smell. Solution: Clean the
air filter. * If the problem persists after cleaning the filters, the
air conditioner should be cleaned and serviced by an Authorized
Trane dealer)
You may hear “Water Flowing” noise when the air conditioner is
running.
When the air conditioner is started, or the compressor is started or
stopped during running or the air conditioner is stopped, sometimes
you may hear the flowing sound of refrigerant.
Sometimes a thin fog will flow out of the outlet when air conditioner is
running under cooling mode.
This might occur when indoor temperature and humidity are high. This
is because the indoor air is quickly cooled down.
After a period of time, the fog will disappear with the decrease of
indoor temperature and humidity.
You may hear a slight crack when the air conditioner is started or
stopped.
This is the sound caused by expansion of plastic panel or other parts
due to the change of temperature.
The unit can not run
* Has the power been shut down?
* Does power plug come loose from the socket?
* Is the circuit protection device tripped off or not?
* Is voltage higher or lower? (Tested by professionals)
* Is the Timer correctly used?
Cooling(Heating) efficiency is not good.
* Is Temp. setting suitable?
* Were inlet and outlet vents obstructed?
* Is there too much dust accumulated and obstructed the filter?
* Are the windows and doors closed?
* Did Fan speed set at low speed?
* Is there any heat sources in the room?
Wireless remote control is not functioning
* Is it in its receiving range? Or obstructed?
* Check and/or replace the batteries.
* The wireless remote control is damaged.
Water leakage in the room
* The air humidity is on the high side. * Water overflowing due to
blocked drain tube. Call your Authorized Trane dealer.
* The connection position of indoor unit drainage pipe is loose.
Water leakage in outdoor unit
* When the unit is running in the COOL mode, moisture from the
indoor space will be discharged from the drain pipe.
* When the unit is running in the HEAT mode, moisture may drip from
the outdoor coil.
* When the unit is running in Auto Defrost mode, frost that has formed
on the outdoor coil will be thawed.