Indoor Unit
WARNING
Adequate Support!
Wall structure must be adequate to support the weight of the unit. Failure to ensure
adequate structural support could result in unit falling from its location which could
result in death, serious injury, or equipement or property-only damage.
1.
The air inlet and outlet should be far away from anything that could prevent the air from
reaching all parts of the room.
2.
Select a location where it is easy to drain the condensing water and connect to the outdoor
unit;
3.
Keep the indoor unit far away from heat sources, vapor and inflammable gas;
4.
Be sure that the installation of the indoor unit conforms to the installation dimension
diagram;
5.
Be sure to leave enough space to allow access for routine maintenance; clearance between
the indoor unit and the floor should
6.
Install in a location where the
ay from other electric appliances
such as television, audio devices etc.;
7.
Select location where air filters can be easily removed
Outdoor unit
WARNING
Adequate Support!
Wall structure must be adequate to support the weight of the unit. Failure to ensure
adequate structural support could result in unit falling from its location which could
result in death, serious injury, or equipement or property-only damage.
1.
Select a location from which noise and air discharge by unit will not annoy neighbors.
2.
Select a location where there is sufficient ventilation.
3.
Make sure the air inlet and outlet are not blocked by any obstacles.
4.
Select a location capable of supporting the weight and vibration of the outdoor unit, and
where installation work can be carried out safely.
5.
Select a location away from flammable gas or gas leaks.
6.
Make sure that the installation of the outdoor unit conforms to the installation dimension
diagram.
NOTICE
Installing the unit in one of the following locations could result in unit malfunction:
•
Places where oil (machine oil) is used
•
Seaside/places with high level of salt in the air.
•
Places with high level of sulfur gas such as areas with hot springs.
•
Places where high-frequency waves are generated by radio equipment, welders and medical
equipment.
•
Other unusual places where unit operation may be altered.
Installation location
be more than 7 feet.
unit is more than 3 feet aw
MS-SVN21A-EN
7
Содержание 2MCW0-G
Страница 6: ...RU 0 PRGHOV SRZHU LQSXW IURP LQGRRU XQLW 0 PRGHO SRZHU LQSXW IURP RXWGRRU XQLW MS SVN21A EN 6...
Страница 18: ...MS SVN21A EN Figure 4 2MWW0512G9 Heat pump indoor units Figure 5 2MCW0518G1 Cooling only indoor units 18...
Страница 21: ...06 691 1 LJXUH11 2TTK0518GB Cooling only outdoor units 10 2MWW0530G1 2MWW0530GB Heat pump indoor units 21...
Страница 26: ...20 2TWK0530G1 2TWK0530GB Heat pump Outdoor unit MS SVN21A EN Figure 21 2TWK0509GB Heat pump outdoor units 26...
Страница 27: ...06 691 1 LJXUH22 2TWK0512GB Heat pump outdoor units 27...