Figure 112.
Performing Cool Test
When all tests are complete, the results are reported as PASS, CHECK, or
FAIL. If the results are CHECK or FAIL, the accompanying alarm codes will
direct the technician to the cause of the problem. If the Pretrip Test results
are CHECK or FAIL, the problem should be diagnosed and corrected before
the unit is released for service.
Figure 113.
Pass, Check, or Fail
Diesel/Electric Menu
The Diesel Mode/Electric Standby menu allows the operator to manually
select diesel or electric mode operation. The unit can also be programmed to
automatically select electric mode operation when standby power is
available and to automatically select diesel mode operation if standby power
fails or is removed. Refer to
“Switching from Diesel to Electric,” p. 39
and
“Switching from Electric to Diesel,” p. 40
for details.
N
No
otte
e:: If the unit is programmed to switch automatically from diesel to
electric and electric to diesel the normal screens do not appear.
Adjust Brightness
The brightness of the HMI Controller display can be adjusted to allow for
changing ambient light conditions. The choices available to the operator are