Tranberg TEF 1058 Скачать руководство пользователя страница 3

Installation and operating manual - TUM5134 

TEF 1058 Heat Trace Thermostat 

 

Warnings and risk levels 

DANGER 

Non-compliance with the instruction results in risk of severe or fatal injuries to persons   

 

WARNING 

Non-compliance with the instruction may result in risk of severe or fatal injuries to persons 

 

CAUTION 

Non-compliance with the instruction may result in risk of injuries or damage to equipment 

 

NOTICE 

Non-compliance with the instruction may result in reduced lifetime of equipment, malfunctions etc. 

 

General information 

Before installation, make sure to read and understand this installation and operating manual. 

Observe national assembly and installation regulations. 

Always contact the manufacturer if anything is unclear, or if you notice any faults on the product or in this 

document. 

This installation and operating manual shall be available to anyone operating, installing, inspecting, modifying or 

repairing the equipment. 

 

 

Содержание TEF 1058

Страница 1: ...ual TUM5134 TEF 1058 Heat Trace Thermostat Installation Manual TEF 1058 Heat Trace Pipe Wall Mounted Thermostat Zone 1 Zone 2 Safe Area Document properties TUM5134 Revision Comment Revision date Approved I New design 07 03 2022 CKR ...

Страница 2: ...fe use 5 Technical data 5 Product description 5 Transport and storage 5 Mounting and installation 6 Mounting of wall mounted type fig 01 6 Mounting of pipe mounted type fig 03 7 Temperature sensor 7 Termination 7 Electrical connections 8 Setting the limit value in accordance with the scale 8 Setting the limit value in accordance with installation specific operational characteristic 8 Maintenance a...

Страница 3: ... of injuries or damage to equipment NOTICE Non compliance with the instruction may result in reduced lifetime of equipment malfunctions etc General information Before installation make sure to read and understand this installation and operating manual Observe national assembly and installation regulations Always contact the manufacturer if anything is unclear or if you notice any faults on the pro...

Страница 4: ...ents The empty enclosures feature a component certificate Therefore the equipment may only be used for its intended use Improper or impermissible use or non compliance with the information in these operating instruction voids any warranty Changes to the equipment that impair the function of the equipment or the explosion protection are not permissible Ex marking Ex de IIC Gb Ex eb IIC Ex e mb IIC ...

Страница 5: ...y other damage caused by such activities Any damage done to the equipment during transportation is not the responsibility of R Stahl Tranberg AS If the content is not complete file a claim to the producer immediately Technical data Property Value Value Explosion protection Ex d e IIC Gb T6 T5 T4 Ex eb IIC Ex e mb IIC Gb Tamb 50 C 50 C Silicone 20 C 40 C Nominal voltage 230 VAC Main switching capac...

Страница 6: ... injuries Mounting of wall mounted type fig 01 Mount the thermostat junction box by at least two Pcs M6 bolts placed diagonally on a wall or proper supported rack Remove dust protection or stopping plugs and install selected gland Use stopping plugs for unused entries Only certified cable glands and stopping plugs may be used Select gland according to the cable diameter used Strap the transition u...

Страница 7: ...that the thermal insulation cannot be tapped between the sensor and the heated surface The sensor is normally fixed to pipe or object by use of aluminum tape Other methods could be thermowells suitable for the application Note The widened area of the capillary tube shall be clamped by the cable gland sealing ring The sealing ring is not dimensioned for the Ø1 5 mm capillary tube Termination In ord...

Страница 8: ...towards the scale start value determine the required switching point position circuit opens and electrical circuit 1 4 is closed Maintenance and cleaning Maintenance according to national regulations and company practice Before opening the junction box make sure that the power is disconnected Servicing the junction box is done be checking the intactness of the junction box gasket and glands If nec...

Страница 9: ...nsidered EE Waste and shall be handled accordingly Observe national and local regulations and statutory regulations regarding disposal Separate materials when sending it for recycling Ensure environmentally friendly disposal of all components No component or packaging shall end up in the ocean during any stage of the product s lifetime ...

Страница 10: ...Heat Trace Thermostat Compliance Conformity Presafe 14ATEX4124 IECEx PRE 14 0001 Applicable standards 2014 34 EU ATEX Directive EN 60079 0 2012 2018 EN 60079 1 2007 2014 EN 60079 7 2007 2015 A1 2018 EN 60079 18 2009 2015 A1 2017 Document no DoC TDC3131 ...

Отзывы: