6
A4610002en.teil1
5.6
Sound information
The A-weighted equivalent continuous sound level at the work place of the machine operator is
typical 84 dB (A).
This value was determined according to DIN 45 635 T3 (11.85).
5.7
Vibration information
The weighted effective value of the acceleration typically amounts to less than 2,5m/s
2
.
This value was determined according to DIN EN 28 662 T1 (01.93).
6
INSTALLATION
6.1
Compressed air connection
The compressed air is connected to the reducing coupling N6.5133 using a coupling. An air-unit consisting of
a separator for water and dirt, a pressure regulator with a manometer and a lubricator should be installed
within a distance of 15 ft/5 meters. The compressed air must be free from dirt, rust and moisture.
6.2
Suspension of tool
It is possible to suspend the tool on a spring loaded balancer using various suspension brackets.
They have to be ordered separately (see paragraph "ACCESSORIES").
7
MAINTENANCE
Depending on the working conditions and the use of the tool the following maintenance has to be made
periodically:
7.1
Air-unit
•
Checking the air-pressure daily (never exceed 87 psi / 6,0 bar).
•
Checking oil-level daily.
•
Checking the water separator daily (unless automatic), draining when necessary.
•
Cleaning the filter following the instructions of the manufacturer of the air-unit.
Oil for the air unit
HL or CL ISO-VG 10
7.2
Lubrication
When being exchanged, all valve parts and other movable parts have to be greased with grease of type
ESSO BEACON 2 or with some equivalent product.
Sales and Service 877-862-6699
WWW.TRADITIONALTOOL.COM