BESMOKEY10
Smoke Alarm, Photoelectric
220
-
240V AC Lithium Battery Wireless Ready
Thank you for purchasing our smoke alarm. This instruction contains
important information on the correct installation and operation of your
smoke alarm. Read this instruction fully before attempting installation and
retain them for future reference.
AS3786:2014
Warning:
• This product must only be installed and serviced by an appropriately qualified electrician.
• Observe and follow all local and national electrical and building codes for installation.
• This product must only be used for the purpose described in these instructions and must be installed in
accordance with the wiring rules and regulations in local region.
• Hazardous voltage may be presented at the wire leads of this product.
• Disconnect the AC power before installing or removing the smoke alarm.
• Ensure that the product has been correctly installed and tested for safe operation before reconnecting the
electrical supply.
• DO NOT connect the interconnection wire to Active or Neutral.
• A non-pure sinusoidal power sources is not suitable for this smoke alarm (e.g. derived from square-wave
invertors).
• The apparatus shall not be exposed to steam or splashing and that no objects filled with liquids, such as
vases, shall be placed on the apparatus.
Failure to follow these instructions may result in death or serious injury.
Specifications:
Main Power Source
220-240 V AC/50 Hz
Secondary Power Source
DC 3V battery: Pairdeer CR17450 or Huiderui CR17450
AC Operating Current
<100mA
Interconnecting
Max. 24 alarms (wired 150m maximum)
Operating Temperature
0 °C to 40 °C
Ambient Humidity
≤ 93%
Alarm Sensitivity
0.122-0.182 dB/m
Alarm Volume
≥ 85dB(A) @ 3m
Sound Pattern
ISO8201(BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s
- pause 1.5s, with the RED LED flashing, repeat this alarm
pattern)
Comply with
AS3786:2014
Product function description:
Function
Indication
Description
Standby status
The Red LED flashes every 40 seconds.
The unit is working.
Alarm Memory Mode
Flashes twice every 20 seconds.
Shows which alarm in network has fault.
AC power indication
The Green LED illuminates continuously.
The unit is receiving AC power.
Low battery warning
The unit chirps with Red LED flashing
every 40 seconds.
The battery voltage is too low, need to replace a new
smoke alarm.
Fault warning
The unit chirps between the Red
LED two times flashing.
The unit is faulty, get helps from the section: “Trouble
Shooting.
Self-test fault warning
The Red LED flashes twice every
40 seconds.
The buzzer fault or buzzer detection circuit fault.
Test function
The Red LED flashes once every second
with alarm sounding until the TEST
button is released.
•
Test by pressing the TEST button on the smoke alarm
at least 5 seconds.
•
The alarm will sound if all electronic circuitry, horn
and battery are working properly.
•
If no alarm sounds, refer to “Trouble Shooting”.
Hush Mode
The Red LED flashes every 8 seconds.
•
This smoke alarm has a built-in Silence feature.
•
If cooking or other non-hazardous sources cause the
alarm to sound, it can be temporarily silenced by
pressing the HUSH button for above 2 seconds.
•
The alarm enters silence mode for 10 minutes.
•
After the 10 minute dormant period, the smoke
alarm will resume normal operation.
Fire alarm
The Red LED flashes every second, with
alarm sounds.
Generate alarm sounds when fire happening.
Interconnection alarm
The unit generate alarm sounds without
Red LED flashing.
The unit will enter the interconnection alarm mode when
received wire interconnection alarm signals.
Do Not Disturb
The Red LED flashes every 40 seconds.
The unit will stop nuisance warning about 10 hours
under low battery or fault mode when the HUSH button
is pressed.
End-of-life warning
The unit chirps between the Red
LED two times flashing.
The unit sends end-of-life warning after working 10 years.
Need to replace a new smoke alarm.
Caution:
•
Before using the silence function, identify the source of the smoke and ensure conditions are safe. The unit will resume
normal operation after 10 minute silence.
•
DO not use an open flame to test your alarm, you could damage the alarm or ignite combustible materials and result in a fire.
•
Pull out the yellow tag insulation sheet in battery compartment before installing smoke alarm, or the smoke alarm won’t
work properly.
•
If the alarm sounds, and it is not being tested, it means the unit detected smoke. THE SOUND OF THE ALARM REQUIRES
YOUR IMMEDIATE ATTENTION AND ACTION.