background image

 

Installation Instructions                        Revised 10/13/2015                 Copyright (C) 2008                    Proverbs 22:29                     Page 7                         
 

 

 
 
 
 
 
 
 

W A R R A N T Y 

 
 
 
 
 
 
 

 

   Kitchen Ventilation Products 

 
What 

IS

 Covered

 

 Trade-Wind

®

 warrants its 

Trade-Wind

®

 Kitchen Ventilation Products to the original user, to be free of   

 defects in materials and workmanship for three (3) years from the date of purchase.   
 

Trade-Wind

® 

at its option, will repair or replace the complete unit or any defective component without charge.  

This warranty may be voided if any unauthorized service, alterations, or repairs are made to the product.   
 

What is 

Not

 Covered 

  Normal maintenance and service of any product that has been subject to misuse, negligence,  

accident, or installation inconsistent with the recommended 

Trade-Wind

® 

Installation Instructions  

and 

Trade-Wind

® 

Best Practices Guidelines.  

  Product(s) used other than for normal in-home use or products used outside of the United States.   

  Damage to the product caused by accident, fire, flood, or other acts of God. 

  Service calls to educate the customer in the proper use and care of the product, change fuses, or to  

reset the circuit breakers. 

  Service calls to correct faulty installation, such as, performance issues relating to improperly sized  

ducting or restrictive roof caps is not covered and will by default be charged back to the Homeowner. 

 
     

Trade-Wind

®

 disclaims and excludes any liability for implied warranties or for incidental or consequential  

     damages wherever permitted by law.  There are no implied warranties of merchantability or fitness for a  
     particular use or purpose.  This warranty gives you specific legal rights and you may also have other rights,  
     which vary from state to state. 
 

  For Service:  

If you need service on your 

Trade-Wind

®

 Kitchen Ventilation or Exhaust Ventilators  

    contact our Customer Service at the Website, physical address, or phone number listed below.   
    Please provide the model number, part identification, and/or serial number along with details of the problem.   
    Proof of purchase may be required. 
 

Warranty Revised 08/12/2015

 

 

 

Universal Metal Industries, Inc. has a policy of continuous improvements and reserves the right to modify (at any time and 
without notice) any or all of its products, features, designs, components and specifications.  

For exact dimensions, see the 

Installation Instructions included with each product

.

   Some features may be slightly different than shown on product literature. 

 

 

 

For more information, please contact your Trade-Wind

®

 Representative 

 

 
 

 

800 West Grant Street, Phoenix, AZ 85007 

 

800 875-3654 Phone     800 809-0995 Fax 
602 251-3654 Phone     602 251-3889 Fax 

twphx.com          trade-windonline.com         umiphx.com            

            

  

Содержание PMB02

Страница 1: ...age or incorrect installation TIPS Contain helpful information to facilitate installation READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have any questions please contact the manufacturer at the address or telephone number listed in the warranty b ...

Страница 2: ...ible 2 Ducts must be of adequate size and duct runs should be as short as possible Where turns are necessary keep turning radius as large and as smooth as possible 3 The ducting must be air tight Use a minimum of 2 sheet metal screws at every duct joint Then seal the duct joints with high quality duct tape 4 Do not use this unit with any solid state speed control device 5 This unit must be grounde...

Страница 3: ...your custom canopy Failure to do so could distort and damage the liner and void the warranty Given that most installations are different a back draft damper is not provided with this unit Always install ventilation products with an approved wall or roof cap Duct performance is improved by using round smooth metal duct work instead of rectangular If multiple elbows must be used ensure that there is...

Страница 4: ...LABEL Because the Trade Wind Standard Series Liner was designed for various wood hood applications no mounting holes have been pre drilled This allows the liner to be attached in most any area of the canopy that has a wood frame support e g the back sides or top We recommend at least six equally spaced screws per liner three screws along the back top or back side panel and three screws on the fron...

Страница 5: ...liner while pressing the front side upwards into place The filters may be cleaned by hand washing in hot water using a mild detergent solution or by placing in an automatic dishwasher Dry the filters before reusing CAUTION Most common scrubber type pads will scratch the liner If a commercially available stainless steel cleaner is used it is important to read the labels for chlorine compounds Chlor...

Страница 6: ... rather than amps divide the watts by 120 and this will give you the amperage rating CAUTION The neutral wire usually white for the ventilator must connect to the same neutral wire that comes from the electrical panel to the liner It is recommended to run a white neutral wire from the liner s white neutral wire along the same path as the red wire from the liner s variable speed control to the vent...

Страница 7: ...ucting or restrictive roof caps is not covered and will by default be charged back to the Homeowner Trade Wind disclaims and excludes any liability for implied warranties or for incidental or consequential damages wherever permitted by law There are no implied warranties of merchantability or fitness for a particular use or purpose This warranty gives you specific legal rights and you may also hav...

Страница 8: ... DO NOT use butt joints c For best air flow elbows and pipe size transition fittings should not be directly connected to one another Where possible always include at least 15 inches of straight pipe between fittings 3 Duct Pipe and Fitting Sizes See Duct Sizing Chart and Area Calculations Section for more detail IMPORTANT DO NOT use either of the following duct pipe sizes or fitting sizes for any ...

Страница 9: ...refully crafted tightly wrapped Aluminum Foil Metal Duct Tape on all connections and physically view and test the damper blades to make certain they are opening and closing correctly Make sure that the damper blades do not touch the duct walls and that there is no debris blocking the free movement of the damper mechanism Common things to look for include screws protruding into the blade s path ove...

Страница 10: ...zed portion of a roof cap or wall cap will cause excessive static pressure that may result in rattling vibration and air buffeting noises as well as inadequate ventilation Roof caps and wall caps must have an integral bird screen 6 Attaching Duct to House Framework The ventilation system should be attached to the framework in such a manner that the weight of the duct and fittings is supported with...

Страница 11: ...7 Round Metal Duct 38 5 38 5 8 Diameter Round 50 25 8 Round Metal Duct or 6 x 9 Rectangular Metal Duct 50 25 54 50 25 54 10 Diameter Round 78 5 10 Round Metal Duct 78 5 78 5 3 25 x 10 Rectangular 32 5 3 25 x 10 Rectangular Metal Duct 32 5 32 5 Calculating Square Inches of Various Duct Sizes Types ROUND DUCT RECTANGULAR DUCT Radius x Radius x 3 1416 Area Sq Inches Width x Depth Area Sq Inches x x x...

Отзывы: