45
Maintenance
Disconnect the arms from the print head
Now gently disconnect the magnetic arms with some small force from the print head.
Installing new print head
Put the new print head on the magnets. With a T1250 watch carefully where the arms need to be attached to the
balls on the print head.
Secure the main cable to the print head by plugging in the connector and tighten the screw fitting.
Push back in the bowden tube until you can’t get in any further. Place the blue clip (if present) back under the
black ring of the bowden tube.
Restart the printer by turning it off and on again or pressing the
STOP
button on the LCD screen.