M 6067 M
rev 11 – 02/2022
Page 23/92
GB
REPLACEMENT OF THE INDEXING LEVER OF THE PULLEY
To remove the indexing lever & spring.
Unscrew the 4 screws (5)
et FTE washers (14),
remove the ring (2)
Remove the FTE
washer (14)
Remove the lever (6)
Remove the spring (7)
install the new lever, proceed as follows.
Position the spring (7)
Position the lever (6)
Position the FTE
washer (14)
Positions the ring (2) and
screw the 4 screws (5)
with FTE washers (14)
ELECTRICAL CONTROL AND POWER SUPPLY
2
▪
PalTurn™ without electrical cabinet (0.5t & 1t as standard)
□
PalTurn™ must be connected to a source protected by fuses or magneto-thermal circuit breaker
matched to the power of the motor (user's responsibility)
□
PalTurn™ is equipped with a wired control for direct motor command. It is connected to the turner
on a terminal block.
2
Wiring diagrams attached at the end of the document.